Daigo Setoyama

Dr. Daigo Setoyama

Toyota Central R&D Labs., Inc.
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2019 in Science
Verified
Journal Article
Closed access
PDF file
YHYujiro Hayashi
Yujiro Hayashi
DSDaigo Setoyama
Daigo Setoyama
YHYoshiharu Hirose
Yoshiharu Hirose
TYTomoyuki Yoshida
Tomoyuki Yoshida
HKHidehiko Kimura
Hidehiko Kimura
Probing polycrystals' stress: The way that a polycrystalline material deforms is in part determined by internal stresses between and within crystal grains. Hayashi et al. developed an x-ray method for mapping the intragranular stresses in a polycrystalline material. They found surprisingly large stresses, which are important for the fundamental understanding of how these materials will fail. This method will work for other materials and provides important information for multiscale deformation modeling. Science , this issue p. 1492

30 April 2010 in International Journal of Plasticity
Verified
Journal Article
Closed access
Ikumu WatanabeIkumu Watanabe
Ikumu Watanabe
DSDaigo Setoyama
Daigo Setoyama
NINoritoshi Iwata
Noritoshi Iwata
KNKoukichi Nakanishi
Koukichi Nakanishi

19 February 2024 in Communications Engineering
Verified
Journal Article
Open access
PDF file
YHYuki Higuchi
Yuki Higuchi
WYWataru Yoshimune
Wataru Yoshimune
SKSatoru Kato
Satoru Kato
SHShogo Hibi
Shogo Hibi
DSDaigo Setoyama
Daigo Setoyama
YNYasutaka Nagai
Yasutaka Nagai
The automotive industry aims to ensure the cold-start capability of polymer electrolyte fuel cells (PEFCs) for developing fuel cell electric vehicles that can be driven in cold climates. Water and ice behavior is a key factor in maintaining this capability. Previously reported methods for visualizing water and/or ice are limited to small-sized PEFCs ( < 50 cm2), while fuel cell electric vehicles are equipped with larger PEFCs. Here, we developed a system using a pulsed spallation neutron beam to visualize water distribution and identify water/ice phases in practical-sized PEFCs at a cold start. The results show direct evidence of a stepwise freezing behavior inside the PEFC. The produced water initially accumulated at the center of the PEFC and then froze, followed by PEFC shutdown as freezing progressed. This study can serve as a reference to guide the development of cold-start protocols, cell design, and materials for next-generation fuel cell electric vehicles.

29 May 2023 in Quantum Beam Science
Verified
Journal Article
Open access
PDF file
YHYujiro Hayashi
Yujiro Hayashi
DSDaigo Setoyama
Daigo Setoyama
KFKunio Fukuda
Kunio Fukuda
KOKatsuharu Okuda
Katsuharu Okuda
NKNaoki Katayama
Naoki Katayama
HKHidehiko Kimura
Hidehiko Kimura
Recently, nondestructive evaluation of the stresses localized in grains was achieved for plastically deformed low-carbon steel using scanning three-dimensional X-ray diffraction (S3DXRD) microscopy with a conical slit. However, applicable metals and alloys were restricted to a single phase and evaluated stress was underestimated due to the fixed Bragg angles of the conical slit optimized to αFe. We herein propose S3DXRD with a rotating spiral slit adaptable to various metals and alloys and accurate stress evaluation with sweeping Bragg angles. Validation experiments with a 50-keV X-ray microbeam were conducted for low-carbon steel as a body-centered cubic (BCC) phase and pure Cu as a face-centered cubic (FCC) phase. As a result of orientation mapping, polygonal grain shapes and clear grain boundaries were observed for both BCC and FCC metals. Thus, it was demonstrated that S3DXRD with a rotating spiral slit will be applicable to various metals and alloys, multiphase alloys, and accurate stress evaluation using a X-ray microbeam with a higher photon energy within an energy range determined by X-ray focusing optics. In principle, this implies that S3DXRD becomes applicable to larger and thicker metal and alloy samples instead of current miniature test or wire-shaped samples if a higher-energy X-ray microbeam is available.

17 August 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
SYSatoshi Yamaguchi
Satoshi Yamaguchi
SKSatoru Kato
Satoru Kato
WYWataru Yoshimune
Wataru Yoshimune
DSDaigo Setoyama
Daigo Setoyama
AKAkihiko Kato
Akihiko Kato
KUKentaro Uesugi
Kentaro Uesugi
An X-ray computed nano-tomography (nano-CT) system has been established at the BL33XU beamline of SPring-8. The optical system consists of pseudo-Köhler illumination with a sector condenser zone plate, an apodization Fresnel zone plate as the objective lens, and a Zernike phase plate. The imaging detector is a fiber-coupling type X-ray camera. The performance of the X-ray nano-CT system was confirmed by imaging an X-ray test chart. The system was subsequently applied to the observation of a microporous layer for polymer electrolyte fuel cells and a simulated microporous layer including liquid water. The nano-CT system, which can perform a computed tomography measurement in less than 4 min, allowed visualization of a spherical water droplet produced in the microporous layer. In the present study, the shape of water droplets in a nanoscale porous structure is investigated.

3 August 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
KIK. Isegawa
K. Isegawa
DSDaigo Setoyama
Daigo Setoyama
YHY. Higuchi
Y. Higuchi
YMY. Matsumoto
Y. Matsumoto
YNY. Nagai
Y. Nagai
TST. Shinohara
T. Shinohara