This paper proposes an eddy current testing (ECT) probe with high-resolution tunneling magnetoresistance (TMR) array sensors for vector magnetic field measurement. The probe consists of two printed circuit boards (PCBs), which are placed perpendicular to each other. Three arrays of TMR sensors are wire bonded on the two PCBs to measure the three components of the magnetic field. Each array contains 32 sensors and the distance between the centers of two adjacent sensors in an array is 0.5 mm. The 32 output signals of each array are multiplexed, amplified and filtered by using a circuit on the PCB. An experimental system is set up and aluminum samples with machined defects are imaged by the probe. It is seen that the patterns of the images along the x-, y- and z-axis are different, meaning the information in the three images can compensate each other to a certain extent. The images change their orientations if the defects are oriented along different angles. An image processing algorithm including image segmentation, normalization, edge detection and K-means classification is developed to class the defects. It is seen that the defects can be classified accurately with the algorithm. Then, the orientations of the defects are calculated from the images with a linear regression of the angles of the three axis images. It is found that the mean error of the orientation quantification is only 4.14°, which is much smaller than the mean error calculated from each axis image separately.
Tunnel magnetoresistance (TMR) is a kind of magnetic sensor with the advantages of low cost and high sensitivity. For ultra-weak and low-frequency magnetic field measurement, the TMR sensor is affected by the 1/f noise. This paper proposes an AC modulation method with impedance compensation to improve the performance. The DC and AC characteristics of the sensors were measured and are presented here. It was found that both the equivalent resistance and capacitor of the sensors are affected by the external magnetic field. The TMR sensors are connected as a push–pull bridge circuit to measure the magnetic field. To reduce the common-mode noise, two similar bridge circuits form a magnetic gradiometer. Experimental results show that the sensor’s sensitivity in the low-frequency range is obviously improved by the modulation and impedance compensation. The signal-to-noise ratio of the sensor at 1 Hz was increased about 25.3 dB by the AC modulation, impedance compensation, and gradiometer measurement setup. In addition, the sensitivity of the sensor was improved from 165.2 to 222.1 mV/V/mT. Ultra-weak magnetic signals, namely magnetocardiography signals of two human bodies, were measured by the sensor in an unshielded environment. It was seen that the R peak of MCG can be clearly visualized from the recorded signal.
18 February 2022 in IEEE Transactions on Instrumentation and Measurement
Current sensors based on the fluxgate magnetic field meter and feedback zero-field operating principle have excellent current measurement accuracy and linearity in a large range of up to thousands of amperes. An excitation current (Ie) is employed in a magnetic fluxgate sensor to magnetize the magnetic core periodically, which will generate magnetization distortion that affects the performance of the sensor. This paper proposes a novel scheme for suppressing the magnetization distortion through an electrical compensation. The source of the magnetization distortion is theoretically derived and analyzed. It is found that the magnetization distortion is a function of the excitation current Ie and is not affected by the primary current. Since Ie is a periodical current that is determined by the parameters of the sensor itself, it is feasible to inject a specified periodical current to the output port of the sensor to cancel the magnetization distortion. Compared with the magnetization distortion compensation method with an additional core and coil, this method does not need to pair the cores or coils, which significantly reduces the complexity of the production process and saves space for the sensor. A prototype sensor with electrical compensation is designed, fabricated and tested. Experimental results show that the compensation setting significantly suppresses the magnetization distortion signal. The amplitude of the basic frequency component is reduced from 24 μV to 6.8 μV. The other odd harmonics of the magnetization distortion are also reduced. The electrical compensation method works properly in a large current range from -1.5 kA to 1.5 kA. The scale accuracy of the prototype sensor is less than 5.7 ppm (parts per million). The compensation method can suppress the magnetization distortion to a similar level with operating temperature changes from room temperature to 50 °C.