This paper presents a novel calibration procedure as a simple, yet powerful, method to place and align inertial sensors with body segments. The calibration can be easily replicated without the need of any additional tools. The proposed method is validated in three different applications: a computer mathematical simulation; a simplified joint composed of two semi-spheres interconnected by a universal goniometer; and a real gait test with five able-bodied subjects. Simulation results demonstrate that, after the calibration method is applied, the joint angles are correctly measured independently of previous sensor placement on the joint, thus validating the proposed procedure. In the cases of a simplified joint and a real gait test with human volunteers, the method also performs correctly, although secondary plane errors appear when compared with the simulation results. We believe that such errors are caused by limitations of the current inertial measurement unit (IMU) technology and fusion algorithms. In conclusion, the presented calibration procedure is an interesting option to solve the alignment problem when using IMUs for gait analysis.
This paper presents the application of polymer optical fiber (POF) sensors in wearable devices for gait assistance. Intensity variation-based POF curvature sensor for the acquisition of joint angles and a POF insole based to detect gait events were developed. Three wearable devices were employed for the practical validation of the developed sensors: an active orthosis with one degree of freedom, a robotic exoskeleton and a functional electrical stimulation (FES) system for gait assistance. POF is a viscoelastic material, which does not have a constant response to stress or strain and also can present hysteresis in dynamic measurements. In order to mitigate these effects, a compensation technique based on the polymer viscoelastic features was applied on both curvature sensor and instrumented insole. The results obtained for the POF curvature sensor on the knee joint angle measurement of the orthosis and exoskeleton show root mean squared error (RMSE) of 3.7° and 3.8°, respectively. Regarding the POF insole results, it was used to identify five gait events in the FES system application. The reported results pave the way for new instrumentation approaches in wearable devices with flexible sensors that can be especially desirable in the rigid robots presented, but also in soft robotics applications.
20 April 2020 in IEEE Journal of Biomedical and Health Informatics
The knee flexion-extension angle is an important variable to be monitored in various clinical scenarios, for example, during physical rehabilitation assessment. The purpose of this work is to develop and validate a sensor fusion system based on a knee sleeve for monitoring of physical therapy. The system consists of merging data from two inertial measurement units (IMUs) and an intensity-variation based Polymer Optical Fiber (POF) curvature sensor using a quaternion-based Multiplicative Extended Kalman Filter (MEKF). The proposed data fusion method is magnetometer-free and deals with sensors' uncertainties through reliability intervals defined during gait. Walking trials were performed by twelve healthy participants using our knee sleeve system and results were validated against a gold standard motion capture system. Additionally, a comparison with other three knee angle estimation methods, which are exclusively based on IMUs, was carried out. The proposed system presented better performance (mean RMSE < 3.3°, LFM coefficients, a $_1$ = 0.99 — 0.04, a $_0$ = 0.70 — 2.29, R $^2$ = 0.98 ±0.01 and P $_C$ > 0.99) when compared to the other evaluated methods. Experimental results demonstrate the usability and feasibility of our system to estimate knee motion with high accuracy, repeatability, and reproducibility. This wearable system may be suitable for motion assessment in rehabilitation labs in future studies.
This paper presents a comparison between a multiple red green blue-depth (RGB-D) vision system, an intensity variation-based polymer optical fiber (POF) sensor, and inertial measurement units (IMUs) for human joint angle estimation and movement analysis. This systematic comparison aims to study the trade-off between the non-invasive feature of a vision system and its accuracy with wearable technologies for joint angle measurements. The multiple RGB-D vision system is composed of two camera-based sensors, in which a sensor fusion algorithm is employed to mitigate occlusion and out-range issues commonly reported in such systems. Two wearable sensors were employed for the comparison of angle estimation: (i) a POF curvature sensor to measure 1-DOF angle; and (ii) a commercially available IMUs MTw Awinda from Xsens. A protocol to evaluate elbow joints of 11 healthy volunteers was implemented and the comparison of the three systems was presented using the correlation coefficient and the root mean squared error (RMSE). Moreover, a novel approach for angle correction of markerless camera-based systems is proposed here to minimize the errors on the sagittal plane. Results show a correlation coefficient up to 0.99 between the sensors with a RMSE of 4.90 , which represents a two-fold reduction when compared with the uncompensated results (10.42 ). Thus, the RGB-D system with the proposed technique is an attractive non-invasive and low-cost option for joint angle assessment. The authors envisage the proposed vision system as a valuable tool for the development of game-based interactive environments and for assistance of healthcare professionals on the generation of functional parameters during motion analysis in physical training and therapy.
5 November 2019 in Journal of Mechanical Engineering and Biomechanics