Masanobu Tsurumoto

Mr. Masanobu Tsurumoto

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RIRumi Iwai
Rumi Iwai
TSTakunori Shimazaki
Takunori Shimazaki
YKYoshifumi Kawakubo
Yoshifumi Kawakubo
KFKei Fukami
Kei Fukami
SAShingo Ata
Shingo Ata
DADaisuke Anzai
Daisuke Anzai
The condition of arteriovenous fistula (AVF) blood flow is typically checked by using auscultation; however, auscultation should require a qualitative judgment dependent on the skills of doctors, and further attention to contact infection is required. For these reasons, this study developed a non-contact and non-invasive medical device to measure the pulse wave of AVFs by applying optical imaging technology. As a first step toward realization of the quantification judgment based on non-contact AVF measurement, we experimentally validated the developed system, whereby the hemodynamics of 168 subjects were visually and quantitatively evaluated based on clinical tests. Based on the evaluation results, the fundamental statistical characteristics of the non-contact measurement, including the average and median values, and distribution of measured signal-to-noise power ratio, were demonstrated. The clinical test results contributed to the future construction of quantified criteria for the AVF condition with the non-contact measurement.

16 July 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MTMasanobu Tsurumoto
Masanobu Tsurumoto
TSTakunori Shimazaki
Takunori Shimazaki
JHJaakko Hyry
Jaakko Hyry
YKYoshifumi Kawakubo
Yoshifumi Kawakubo
TYTakeshi Yokoyama
Takeshi Yokoyama
DADaisuke Anzai
Daisuke Anzai
Peripheral circulatory failure refers to a condition in which the blood flow through superficial capillaries is markedly reduced or completely occluded. In clinical practice, nurses strictly adhere to regular repositioning protocols to prevent peripheral circulatory failure, during which the skin condition is evaluated visually. In this study, skin colour changes resulting from pressure application were continuously captured using a camera, and supervised machine learning was employed to classify the data into two categories: before and after pressure. The evaluation of practical colour space components revealed that the h component of the JCh colour space demonstrated the highest discriminative performance (Area Under the Curve (AUC) = 0.88), followed by the a* component of the CIELAB colour space (AUC = 0.84) and the H component of the HSV colour space (AUC = 0.83). These findings demonstrate that it is feasible to quantitatively evaluate skin colour changes associated with pressure, suggesting that this approach can serve as a valuable indicator for dimensionality reduction in feature extraction for machine learning and is potentially an effective method for preventing pressure-induced skin injuries.

13 April 2026 in Medika Teknika : Jurnal Teknik Elektromedik Indonesia
Verified
Journal Article
Open access
MTMasanobu Tsurumoto
Masanobu Tsurumoto
KHKeisuke Hayashi
Keisuke Hayashi
This research quantitatively evaluated the effect of micro-air inclusion on the dynamic response and waveform fidelity of disposable arterial pressure monitoring kits under bench-top simulated conditions. Frequency-response analysis based on the fast-flush square-wave test and transfer-function modeling was performed using a BIO-TEK 601A simulator and Transfer Function Monitor software. Disposable arterial pressure transducer kits with different closed sampling-port configurations were tested. A defined 0.2 mL air bubble was intentionally introduced into the circuit, and the natural frequency (fn), damping coefficient (ζ), phase delay, and pressure waveform reproducibility were evaluated under simulated aortic and radial waveform settings at 90 and 120 bpm. Micro-air inclusion markedly deteriorated the dynamic response of the monitoring system. The natural frequency declined to 8.5 Hz in the 1 Planecta + air configuration and to 3.8 Hz in the 2 Planecta + air configuration, while the damping coefficient rose to 0.25 and 0.46, respectively. Phase delay increased to 29.60 ms and 120.68 ms in the corresponding air-inclusion configurations. In this simulator setting, systolic pressure was overestimated by up to 13 mmHg compared with the standard kit. Although diastolic and mean pressures were less affected under the same simulator conditions, systolic overestimation may still be relevant for engineering interpretation of waveform fidelity. However, the present research did not assess actual patient measurements, and the findings should therefore be interpreted as bench-top engineering data rather than direct clinical accuracy data.

10 November 2026 in Current Biomedicine
Verified
Journal Article
Open access
PDF file
MTMasanobu Tsurumoto
Masanobu Tsurumoto
Background Under-mattress millimeter-wave radar may provide unobtrusive respiratory sensing, but signal morphology can vary with sensor position and estimation method. This study aimed to compare frequency-domain and time-domain respiratory rate estimation using simultaneous dual-position under-mattress radar measurements. Methods Three healthy adult volunteers underwent supine instructed breathing at 10, 12, and 15 breaths/min. Two XM125 60-GHz-class radar modules were operated simultaneously beneath an 8-cm non-coil medical mattress at positions aligned with the sternal angle and xiphoid process. Each condition was repeated three times, yielding 27 paired trials and 54 radar recordings. The respiratory rate was estimated using a power spectral density method and time-domain peak detection. Mean absolute error, root mean square error, paired position differences, and exploratory harmonic characteristics of peak-detection failures were examined. Results Estimation based on power spectral density yielded a mean absolute error of 0.472 breaths/min and a root mean square error of 0.479 breaths/min, compared with 1.710 and 2.250 breaths/min for peak detection. The mean paired difference between sensor positions was +0.037 breaths/min for power spectral density estimation and +0.164 breaths/min for peak detection. Power spectral density estimates differed by no more than 0.05 breaths/min in 26 of 27 paired trials. Recordings with peak-detection errors greater than 1.0 breaths/min showed higher second- and third-harmonic ratios. Conclusion Under controlled instructed-breathing conditions, power spectral density-based estimation showed smaller deviations from the instructed breathing rates than simple peak detection, whereas the two positions generally yielded similar frequency-domain estimates. These findings are technical results relative to instructed breathing rates and do not constitute clinical validation.