Muhammad Umair Nathani

Mr. Muhammad Umair Nathani

University of Windsor
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
HNHaleh Nazemi
Haleh Nazemi
JBJenitha Antony Balasingam
Jenitha Antony Balasingam
SSSiddharth Swaminathan
Siddharth Swaminathan
KAKenson Ambrose
Kenson Ambrose
MNMuhammad Umair Nathani
Muhammad Umair Nathani
AEArezoo Emadi
Arezoo Emadi
Microelectromechanical system (MEMS)-based mass sensors are proposed as potential candidates for highly sensitive chemical and gas detection applications owing to their miniaturized structure, low power consumption, and ease of integration with readout circuits. This paper presents a new approach in developing micromachined mass sensors based on capacitive and piezoelectric transducer configurations for use in low concentration level gas detection in a complex environment. These micromachined sensors operate based on a shift in their center resonant frequencies. This shift is caused by a change in the sensor’s effective mass when exposed to the target gas molecules, which is then correlated to the gas concentration level. In this work, capacitive and piezoelectric-based micromachined sensors are investigated and their principle of operation, device structures and configurations, critical design parameters and their candidate fabrication techniques are discussed in detail.

25 December 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
MNMuhammad Umair Nathani
Muhammad Umair Nathani
HNHaleh Nazemi
Haleh Nazemi
Calvin LoveCalvin Love
Calvin Love
YLYameema Babu Lopez
Yameema Babu Lopez
SSSiddharth Swaminathan
Siddharth Swaminathan
AEArezoo Emadi
Arezoo Emadi
Advancements in microfabrication technologies and novel materials have led to new innovations in miniaturized gas sensors that can identify miniscule changes in a complex environment. Micromachined resonators with the capability to offer high sensitivity and selectivity in array integration make mass loading a potential mechanism for electronic nose applications. This paper investigates the mass sensing characteristics of progressive capacitive based micromachined resonators as potential candidates for volatile organic compound detection where also there is a need for miniaturized array configuration. In this paper, a detailed investigative review of the major three geometric designs of capacitive based micromachined resonators, namely, the microcantilever, the microbridge and the clamped membrane sensors is performed. Although many reviews are present in literature regarding mass sensors, however there is a gap in the literature regarding the common capacitive based micromachined mass sensors. This research gives a review on the foundation for capacitive based micromachined mass sensors while highlighting the potential capabilities of each geometric design to be developed further. Moreover, this paper also introduces the advancements based on the geometric designs of the capacitive based micromachined mass sensors. An in-depth analysis is done for each geometric design, to identify the critical design parameters, which affect the sensors’ performances. Furthermore, the theoretically achievable mass sensitivity for each capacitive based micromachined mass sensor is modeled and analyzed using finite element analysis with mass variation in the picogram range. Finally, a critical analysis is done on the sensor sensitivities and further discussed in detail wherein each design is compared to each other and its current advances. Additionally, an insight to the advantages and disadvantages associated with each simulated geometry and its different advances are given. The results of the investigative review and analysis indicate that the sensitivities of the capacitive based micromachined sensors are dependent not only on the material composition of the devices but also on the varying degrees of clamping between the sensor geometries. In essence, the paper provides future research the groundwork to choose proper candidate geometry for a capacitive based micromachined mass sensor, with its several advantages over other mass sensors, based on the needed application.

11 January 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
PMPavithra Munirathinam
Pavithra Munirathinam
HNHaleh Nazemi
Haleh Nazemi
MNMuhammad Umair Nathani
Muhammad Umair Nathani
GRGian Carlo Antony Raj
Gian Carlo Antony Raj
YEYoussef Ezzat Elnemr
Youssef Ezzat Elnemr
AEArezoo Emadi
Arezoo Emadi
A novel biasing scheme having the potential to dynamically control the effective cavity heights of two fabricated, multiple moving membrane capacitive micromachined ultrasonic transducers (M 3 -CMUTs) has been developed. With this unique approach it is may be possible to avoid design trade-off requirements of the ultrasonic transducers that affect both receiving and transmitting operating modes. Each of these M 3 -CMUTs has two vibrating membranes suspended over a fixed bottom electrode. The two air-coupled M 3 -CMUT devices with the resonant frequencies of 1MHz single cell and 1.5MHz array device were fabricated. Finite Element Analysis (FEA) was carried out to investigate the effect of an additional middle membrane on the effective cavity height and device performance. Experimental validation was then completed with the transducers operating under both positive and negative biasing conditions of middle membrane, while keeping the top membrane at selected positive biasing voltages to realize a dynamically controlled range of effective cavity heights. The new biasing scheme may facilitate dynamic tunning of resonant frequencies of transmitter and receiver transducers through the variation of effective cavity height for improved performance.

29 July 2024 in IEEE Sensors Letters
Verified
Journal Article
Closed access
AGAnnalise Gignac
Annalise Gignac
ASAkib Shamsuddin
Akib Shamsuddin
HNHaleh Nazemi
Haleh Nazemi
MNMuhammad Umair Nathani
Muhammad Umair Nathani
AEArezoo Emadi
Arezoo Emadi
An innovative technique is explored, aiming to expand the limit of detection (LOD) and increase operating resonant frequency of capacitive micromachined ultrasonic transducer (CMUT) working as a mass sensor through modifying anchor widths. Limit of detection is associated with the concentration range of target compounds and therefore, their correspondent mass that can be measured using a CMUT mass sensor. Poly Multi-User MEMS Process (PolyMUMPs) sacrificial technique is used to fabricate three CMUT sensors with a range of anchor widths while keeping all other sensor design parameters and material properties constant. Experimental analysis is conducted to evaluate the influence of anchor width to resonant frequency and frequency shift at different biasing conditions. The experimental results demonstrates that a larger anchor width can increase CMUT operating resonant frequency and pull-in voltage, allowing for expanded LOD. These results also agree with analytical expressions presented. In addition, it is shown that through employing a designed anchor width, resonant frequencies can be varied to fulfill specific sensor requirements with minimal fabrication adjustments. This study contributes to the evolving knowledge of CMUT as a mass sensor, enabling more methods for variability of these devices.