This work is a comprehensive review of sensing materials, which interact with several target gases pertinent to agricultural monitoring applications. Sensing materials which interact with carbon dioxide, water vapor (relative humidity), hydrogen sulfide, ethylene and ethanol are the focus of this work. Performance characteristics such as dynamic range, recovery time, operating temperature, long-term stability and method of deposition are discussed to determine the commercial viability of the sensing materials considered in this work. In addition to the sensing materials, deposition methods are considered to obtain the desired sensing material thickness based on the sensor’s mechanism of operation. Various material classes including metal oxides, conductive polymers and carbon allotropes are included in this review. By implementing multiple sensing materials to detect a single target analyte, the issue of selectivity due to cross sensitivity can be mitigated. For this reason, where possible, it is desirable to utilize more than one sensing material to monitor a single target gas. Among those considered in this work, it is observed that PEDOT PSS/graphene and TiO-coated g-CN NS are best suited for CO detection, given their wide dynamic range and modest operating temperature. To monitor the presence of ethylene, BMIM-NTf, SWCNTs and PtTiO offer a dynamic range most suitable for the application and require no active heating. Due to the wide dynamic range offered by SiO/Si nanowires, this material is best suited for the detection of ethanol; a gas artificially introduced to prolong the shelf life of the harvested crop. Finally, among all other sensing materials investigated, it observed that both SWCNTs and CNTs/SnO/CuO are most suitable for HS detection in the given application.
Advancements in microfabrication technologies and novel materials have led to new innovations in miniaturized gas sensors that can identify miniscule changes in a complex environment. Micromachined resonators with the capability to offer high sensitivity and selectivity in array integration make mass loading a potential mechanism for electronic nose applications. This paper investigates the mass sensing characteristics of progressive capacitive based micromachined resonators as potential candidates for volatile organic compound detection where also there is a need for miniaturized array configuration. In this paper, a detailed investigative review of the major three geometric designs of capacitive based micromachined resonators, namely, the microcantilever, the microbridge and the clamped membrane sensors is performed. Although many reviews are present in literature regarding mass sensors, however there is a gap in the literature regarding the common capacitive based micromachined mass sensors. This research gives a review on the foundation for capacitive based micromachined mass sensors while highlighting the potential capabilities of each geometric design to be developed further. Moreover, this paper also introduces the advancements based on the geometric designs of the capacitive based micromachined mass sensors. An in-depth analysis is done for each geometric design, to identify the critical design parameters, which affect the sensors’ performances. Furthermore, the theoretically achievable mass sensitivity for each capacitive based micromachined mass sensor is modeled and analyzed using finite element analysis with mass variation in the picogram range. Finally, a critical analysis is done on the sensor sensitivities and further discussed in detail wherein each design is compared to each other and its current advances. Additionally, an insight to the advantages and disadvantages associated with each simulated geometry and its different advances are given. The results of the investigative review and analysis indicate that the sensitivities of the capacitive based micromachined sensors are dependent not only on the material composition of the devices but also on the varying degrees of clamping between the sensor geometries. In essence, the paper provides future research the groundwork to choose proper candidate geometry for a capacitive based micromachined mass sensor, with its several advantages over other mass sensors, based on the needed application.
A novel electrode configuration is proposed in this article that targets fringing field utilization as a critical design parameter to enhance sensitivity. In this work, the electrode architecture is the cornerstone in enhancing the chemicapacitor sensitivity as compared to existing literature that often use the sensing material as the primary focus to achieve low-level detection. The proposed electrode configuration consists of multiple dimple-shaped interdigitated electrodes. The results obtained from the finite element analysis conducted in this work reveal that it is possible to increase fringing field utilization by up to 82% by adopting this unique electrode geometry. The proposed design along with the conventional sensor designs are micromachined using PolyMUMPs fabricated electrodes and a PVA polymer sensing material is used to measure the output capacitance as a proof of concept. When exposed to 40-85% humidity in the same controlled environment, the proposed design offers a 76-149 times greater sensitivity compared to the conventional designs. As such, the findings of this research suggest a means to ameliorate chemicapacitor gas sensors for low-level detection, which can be implemented in agricultural greenhouses to monitor the controlled plant growing environment, among many other applications.