Umar Javed

Mr. Umar Javed

Comsats University Islamabad Lahore Campus
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
Umar JavedUmar Javed
Umar Javed
KIKhalid Ijaz
Khalid Ijaz
MJMuhammad Jawad
Muhammad Jawad
EAEjaz Ahmad Ansari
Ejaz Ahmad Ansari
Noman ShabbirNoman Shabbir
Noman Shabbir
Oleksandr HusevOleksandr Husev
Oleksandr Husev
Power system planning in numerous electric utilities merely relies on the conventional statistical methodologies, such as ARIMA for short-term electrical load forecasting, which is incapable of determining the non-linearities induced by the non-linear seasonal data, which affect the electrical load. This research work presents a comprehensive overview of modern linear and non-linear parametric modeling techniques for short-term electrical load forecasting to ensure stable and reliable power system operations by mitigating non-linearities in electrical load data. Based on the findings of exploratory data analysis, the temporal and climatic factors are identified as the potential input features in these modeling techniques. The real-time electrical load and meteorological data of the city of Lahore in Pakistan are considered to analyze the reliability of different state-of-the-art linear and non-linear parametric methodologies. Based on performance indices, such as Root Mean Square Error (RMSE), Mean Absolute Percentage Error (MAPE) and Mean Absolute Error (MAE), the qualitative and quantitative comparisons have been conferred among these scientific rationales. The experimental results reveal that the ANN–LM with a single hidden layer performs relatively better in terms of performance indices compared to OE, ARX, ARMAX, SVM, ANN–PSO, KNN, ANN–LM with two hidden layers and bootstrap aggregation models.

1 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
Umar JavedUmar Javed
Umar Javed
NMNeelam Mughees
Neelam Mughees
MJMuhammad Jawad
Muhammad Jawad
OAOmar Azeem
Omar Azeem
Ghulam AbbasGhulam Abbas
Ghulam Abbas
UTUmair Tahir
Umair Tahir
The concept of hybrid high-voltage alternating current (HVAC) and high-voltage direct current (HVDC) grid systems brings a massive advantage to reduce AC line loading, increased utilization of network infrastructure, and lower operational costs. However, it comes with issues, such as integration challenges, control strategies, optimization control, and security. The combined objectives in hybrid HVAC–HVDC grids are to achieve the fast regulation of DC voltage and frequency, optimal power flow, and stable operation during normal and abnormal conditions. The rise in hybrid HVAC–HVDC grids and associated issues are reviewed in this study along with state-of-the-art literature and developments that focus on modeling robust droop control, load frequency control, and DC voltage regulation techniques. The definitions, characteristics, and classifications of key issues are introduced. The paper summaries the key insights of hybrid HVAC–HVDC grids, current developments, and future research directions and prospects, which have led to the evolution of this field. Therefore, the motivation, novelty, and the main contribution of the survey is to comprehensively analyze the integration challenges, implemented control algorithms, employed optimization algorithms, and major security challenges of hybrid HVAC–HVDC systems. Moreover, future research prospects are identified, such as security algorithms’ constraints, dynamic contingency modeling, and cost-effective and reliable operation.

14 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
UEUmer Ehsan
Umer Ehsan
MJMuhammad Jawad
Muhammad Jawad
Umar JavedUmar Javed
Umar Javed
KZKhurram Zaidi
Khurram Zaidi
Ateeq Ur RehmanAteeq Ur Rehman
Ateeq Ur Rehman
Muhammad ShafiqMuhammad Shafiq
Muhammad Shafiq
In power systems, the programmable numerical differential relays are widely used for the protection of generators, bus bars, transformers, shunt reactors, and transmission lines. Retrofitting of relays is the need of the hour because lack of proper testing techniques and misunderstanding of vital procedures may result in under performance of the overall protection system. Lack of relay’s proper testing provokes an unpredictability in its behavior, that may prompt tripping of a healthy power system. Therefore, the main contribution of the paper is to prepare a step-by-step comprehensive procedural guideline for practical implementation of relay testing procedures and a detailed insight analysis of relay’s settings for the protection of an Extra High Voltage (EHV) auto transformer. The experimental results are scrutinized to document a detailed theoretical and technical analysis. Moreover, the paper also covers shortcomings of existing literature by documenting specialized literature that covers all aspects of protection relays, i.e., from basics of electromechanical domain to the technicalities of the numerical differential relay covering its detailed testing from different reputed manufacturers. A secondary injection relay test set is used for detailed testing of differential relay under test, and the S1 Agile software is used for protection relay settings, configuration modification, and detailed analysis.

27 August 2013 in ACM SIGCOMM Computer Communication Review
Verified
Journal Article
Open access
PDF file
Umar JavedUmar Javed
Umar Javed
ICItalo Cunha
Italo Cunha
DCDavid Choffnes
David Choffnes
EKEthan Katz-Bassett
Ethan Katz-Bassett
TAThomas Anderson
Thomas Anderson
AKArvind Krishnamurthy
Arvind Krishnamurthy
Interdomain path changes occur frequently. Because routing protocols expose insufficient information to reason about all changes, the general problem of identifying the root cause remains unsolved. In this work, we design and evaluate PoiRoot , a real-time system that allows a provider to accurately isolate the root cause (the network responsible) of path changes affecting its prefixes. First, we develop a new model describing path changes and use it to provably identify the set of all potentially responsible networks. Next, we develop a recursive algorithm that accurately isolates the root cause of any path change. We observe that the algorithm requires monitoring paths that are generally not visible using standard measurement tools. To address this limitation, we combine existing measurement tools in new ways to acquire path information required for isolating the root cause of a path change. We evaluate PoiRoot on path changes obtained through controlled Internet experiments, simulations, and "in-the-wild" measurements. We demonstrate that PoiRoot is highly accurate, works well even with partial information, and generally narrows down the root cause to a single network or two neighboring ones. On controlled experiments PoiRoot is 100% accurate, as opposed to prior work which is accurate only 61.7% of the time.