Vinish Vinish

Mr. Vinish Vinish

Roessingh Research and Development, Enschede, The Netherlands
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
MDMohamed S. Draz
Mohamed S. Draz
AVAnish Vasan
Anish Vasan
AMAradana Muthupandian
Aradana Muthupandian
MKManoj Kumar Kanakasabapathy
Manoj Kumar Kanakasabapathy
PTPrudhvi Thirumalaraju
Prudhvi Thirumalaraju
HSHadi Shafiee
Hadi Shafiee
A virus detection method using deep learning–based analysis of smartphone-recorded microchip images without any optical hardware.

3 July 2017 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MKManoj Kumar Kanakasabapathy
Manoj Kumar Kanakasabapathy
HPHardik J. Pandya
Hardik J. Pandya
MDMohamed Shehata Draz
Mohamed Shehata Draz
MCManjyot Kaur Chug
Manjyot Kaur Chug
MSMagesh Sadasivam
Magesh Sadasivam
HSHadi Shafiee
Hadi Shafiee
The most recent guidelines have called for a significant shift towards viral load testing for HIV/AIDS management in developing countries; however point-of-care (POC) CD4 testing still remains an important component of disease staging in multiple developing countries. Advancements in micro/nanotechnologies and consumer electronics have paved the way for mobile healthcare technologies and the development of POC smartphone-based diagnostic assays for disease detection and treatment monitoring. Here, we report a simple, rapid (30 minutes) smartphone-based microfluidic chip for automated CD4 testing using a small volume (30 μL) of whole blood. The smartphone-based device includes an inexpensive (<$5) cell phone accessory and a functionalized disposable microfluidic device. We evaluated the performance of the device using spiked PBS samples and HIV-infected and uninfected whole blood, and compared the microfluidic chip results with the manual analysis and flow cytometry results. Through t-tests, Bland–Altman analyses, and regression tests, we have shown a good agreement between the smartphone-based test and the manual and FACS analysis for CD4 count. The presented technology could have a significant impact on HIV management in developing countries through providing a reliable and inexpensive POC CD4 testing.

22 November 2019 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MKManoj Kumar Kanakasabapathy
Manoj Kumar Kanakasabapathy
PTPrudhvi Thirumalaraju
Prudhvi Thirumalaraju
CBCharles L. Bormann
Charles L. Bormann
HKHemanth Kandula
Hemanth Kandula
IDIrene Dimitriadis
Irene Dimitriadis
HSHadi Shafiee
Hadi Shafiee
Embryo assessment and selection is a critical step in an in vitro fertilization (IVF) procedure. Current embryo assessment approaches such as manual microscopy analysis done by embryologists or semi-automated time-lapse imaging systems are highly subjective, time-consuming, or expensive. Availability of cost-effective and easy-to-use hardware and software for embryo image data acquisition and analysis can significantly empower embryologists towards more efficient clinical decisions both in resource-limited and resource-rich settings. Here, we report the development of two inexpensive (<$100 and <$5) and automated imaging platforms that utilize advances in artificial intelligence (AI) for rapid, reliable, and accurate evaluations of embryo morphological qualities. Using a layered learning approach, we have shown that network models pre-trained with high quality embryo image data can be re-trained using data recorded on such low-cost, portable optical systems for embryo assessment and classification when relatively low-resolution image data are used. Using two test sets of 272 and 319 embryo images recorded on the reported stand-alone and smartphone optical systems, we were able to classify embryos based on their cell morphology with >90% accuracy.

1 April 2019 in Fertility and Sterility
Verified
Journal Article
Closed access
PTP. Thirumalaraju
P. Thirumalaraju
JHJ.Y. Hsu
J.Y. Hsu
CBC.L. Bormann
C.L. Bormann
MKM. Kanakasabapathy
M. Kanakasabapathy
ISI. Souter
I. Souter
HSH. Shafiee
H. Shafiee

19 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
VVVinish Vinish
Vinish Vinish
JBJaap H. Buurke
Jaap H. Buurke
PVPeter Veltink
Peter Veltink
CBChris Baten
Chris Baten
Integrated Ultra-wideband (UWB) and Magnetic Inertial Measurement Unit (MIMU) sensor systems have been gaining popularity for pedestrian tracking and indoor localization applications, mainly due to their complementary error characteristics that can be exploited to achieve higher accuracies via a data fusion approach. These integrated sensor systems have the potential for improving the ambulatory 3D analysis of human movement (estimating 3D kinematics of body segments and joints) over systems using only on-body MIMUs. For this, high accuracy is required in the estimation of the relative positions of all on-body integrated UWB/MIMU sensor modules. So far, these integrated UWB/MIMU sensors have not been reported to have been applied for full-body ambulatory 3D analysis of human movement. Also, no review articles have been found that have analyzed and summarized the methods integrating UWB and MIMU sensors for on-body applications. Therefore, a comprehensive analysis of this technology is essential to identify its potential for application in 3D analysis of human movement. This article thus aims to provide such a comprehensive analysis through a structured technical review of the methods integrating UWB and MIMU sensors for accurate position estimation in the context of the application for 3D analysis of human movement. The methods used for integration are all summarized along with the accuracies that are reported in the reviewed articles. In addition, the gaps that are required to be addressed for making this system applicable for the 3D analysis of human movement are discussed.

3 October 2024 in Engineering Research Express
Verified
Journal Article
Open access
VVVinish Vinish
Vinish Vinish
JRJan Willem A Rook
Jan Willem A Rook
TKThomas Keizers
Thomas Keizers
CVCarsten Voort
Carsten Voort
JBJaap H Buurke
Jaap H Buurke
CBChris T M Baten
Chris T M Baten
Integrated Ultrawideband (UWB) and Magnetic Inertial Measurement Unit (MIMU) sensors are becoming popular for indoor localization applications, as a higher accuracy can be achieved than with just MIMU sensors. These integrated sensors could extend stability and accuracy in the field of 3D analysis of human movement (3D AHM) if they can deliver position estimates with an accuracy close to 1 cm. Achieving this high accuracy of 1 cm remains challenging, with most studies reporting position estimation errors around 5 cm, often due to Non-Line of Sight (NLOS) conditions and systematic UWB sensor distance estimation errors. Studying the distance error characteristic of UWB in situations of 3D AHM is essential to deal with these errors. While research on UWB distance errors in Line of Sight (LOS) and NLOS situations exists, few studies focus on the NLOS errors caused by the human body and were not in the relevant scenarios of 3D AHM. Therefore, this article examines UWB sensor performance and distance error characteristics in LOS and NLOS situations typical for the 3D AHM. Both the LOS and NLOS situations were studied in the typical 3D AHM distance range of 0.2 m to 2 m. The NLOS situations were studied first with a human subject as NLOS causing object and then with simulated human body segments (PVC pipes filled with water) of varying diameters. In LOS situations, consistent systematic bias errors were observed, along with incidental errors at specific positions in the room. In NLOS scenarios caused by the human and simulated body segments, a consistent and reproducible overestimation of distances was found. The reproducibility of these errors based on relative node and object positions suggests that systematic mitigation methods could significantly reduce errors, enabling more accurate and reproducible 3D human movement analysis.