Vinu Thomas George

Dr. Vinu Thomas George

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
ASAlex Leo Sequeira
Alex Leo Sequeira
ANAparna I. Narayan
Aparna I. Narayan
VGVinu Thomas George
Vinu Thomas George

1 December 2015 in World Journal of Dentistry
Verified
Journal Article
Closed access
STSv Siva Teja
Sv Siva Teja
VKVishnu Ravi Kumar
Vishnu Ravi Kumar
VGVinu Thomas George
Vinu Thomas George
Background: The disabilities associated with oral health; like missing teeth, are many. The management of these disabilities is of utmost importance to any dental practitioner. Materials and methods: This study was conducted at the outpatient department (OPD) of Manipal College of Dental Sciences, Manipal, located in Udupi district of South-West Karnataka, with a population of 11.7 lakh of whom 305 patients (146 females and 159 males) took part in the study to assess their awareness to various treatment options available to replace missing teeth. The subjects filled out a close-ended questionnaire of 11 questions; clinical examination of the oral cavity then followed. They all had at least 1 missing tooth (3rd molars excluded). The data were analyzed using SPSS Version 2.0, with a Chi-square test significance level of p < 0.05. Results: Of the 305 patients who participated, 69.2% of males and females wanted to get their teeth replaced. The remaining 15.2% males and 12.6% females who did not want to get their teeth replaced stated that the lack of time prevented them from doing so. A total of 5% of females and a 1.4% of males said that previous traumatic dental experience prevented them from getting treatment. Majority of both men and women were aware of the removable partial prosthesis as a treatment option (71.9% males and 74.9% females). A small portion of the study group, 21.9% males and 25.2% of females were aware of dental implants. The most preferred treatment option, chosen by 53.5% females and 49.3% males was the fixed partial prosthesis (tooth supported). These findings indicate that 56% of women were more inclined to avail treatment for missing teeth, and only 44% of men felt the need to avail treatment. A total of 76.7% males and 76.1% females felt that their masticatory functions were affected. Conclusion: The findings indicate that awareness regarding implants is lacking, and that motivation brought about by outreach programs has not yet reached most sections of the Indian society. How to cite this article: Teja SVS, Kumar VR, George VT. A Survey to Evaluate the Awareness of Various Treatment Modalities to Replace Missing Teeth among Patients Visiting Kasturba Hospital, Manipal: A Prosthodontic Perspective. World J Dent 2015;6(4):217-221.

16 July 2025 in The Journal of Indian Prosthodontic Society
Verified
Journal Article
Open access
TRThumma Sagar Reddy
Thumma Sagar Reddy
VGVinu Thomas George
Vinu Thomas George
GSGauri Shahi
Gauri Shahi
SRSauptik Ray
Sauptik Ray
Aim: To evaluate and compare the surface roughness and impact strength of conventional polymethyl methacrylate (PMMA) with microcrystalline cellulose (MCC)-reinforced PMMA. Settings and Design: An in-vitro experimental study was conducted. Fifty PMMA specimens were fabricated and divided into five groups based on MCC concentration (2% or 5%) and particle size (20 μm or 50 μm). Materials and Methods: Specimens (80 mm × 10 mm × 4 mm) were categorized as follows: Group A (control; conventional PMMA), Groups B and D (2% MCC with 20 µm and 50 µm particles, respectively), and Groups C and E (5% MCC with 20 µm and 50 µm particles, respectively). Surface roughness was measured using a contact profilometer, and impact strength was tested with a ZwickRoell impact testing machine. Statistical Analysis Used: Statistical analysis was performed using IBM SPSS Version 28.0. One-way ANOVA followed by Tukey’s post hoc test was used to determine intergroup differences, with the significance level set at p <0.05. Results: Surface roughness was lower in Groups B (0.89±0.43), C (1.07±0.34), and E (0.77±0.27) compared to the control Group A (1.25±0.42), while Group D (1.84±0.25) showed higher values. Impact strength in Groups C (1.85±0.23), D (1.80±0.17), and E (1.81±0.26) was slightly lower than the control (1.88±0.31), though not statistically significant. However, Group B (1.56 ± 0.20) showed a significant reduction. Conclusion: The addition of 20 μm MCC reduced surface roughness at both 2% and 5% concentrations, whereas 50 μm MCC increased roughness at 2% but decreased at 5%. Impact strength remained comparable to the control in all groups except PMMA + 2% MCC (20 μm), which exhibited a significant decline. MCC reinforcement influences PMMA’s mechanical and surface properties, suggesting its potential for denture base modifications.

1 August 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
SVSwapna B V
Swapna B V
Basavannadevaru ShivamurthyBasavannadevaru Shivamurthy
Basavannadevaru Shivamurthy
VGVinu Thomas George
Vinu Thomas George
KSKavishma Sulaya
Kavishma Sulaya
VNVaishnavi M Nayak
Vaishnavi M Nayak
Background/Objectives: Additive manufacturing (AM) technology has emerged as an innovative approach in dentistry. Recently, manufacturers have developed permanent resins engineered explicitly for the fabrication of definitive prostheses using AM techniques. This systematic review evaluated the mechanical and physical properties of 3D-printed permanent resins in comparison to milled resins and hybrid ceramics for the fabrication of indirect dental restorations. Methods: Three electronic databases—Scopus, Web of Science, and PubMed—were searched for English-language articles. Two independent researchers conducted study selection, data extraction, quality assessment, and the evaluation of the certainty of evidence. In vitro studies assessing the mechanical and physical properties of the permanent resins were included in this review. Results: A total of 1779 articles were identified through electronic databases. Following full-text screening and eligibility assessment, 13 studies published between 2023 and 2024 were included in this qualitative review. The investigated outcomes included physical properties (surface roughness, color changes, water sorption/solubility) and mechanical properties (flexural strength, elastic modulus, microhardness). Conclusions: Three-dimensionally printed permanent resins show promising potential for fabricating indirect dental restorations. However, the current evidence regarding their mechanical and physical properties remain limited and inconsistent, mainly due to variability in study methodologies.

1 September 2016 in World Journal of Dentistry
Verified
Journal Article
Closed access
VGVinu Thomas George
Vinu Thomas George
Although there have been a lot of advances in the field of esthetic and cosmetic restorative dentistry, metal—ceramic restorations stand apart in the race to achieve superior esthetics with its strong points of strength and accuracy of cast metal and esthetics of porcelain. To achieve superior esthetic restorations operators are compelled to narrow down their search to all ceramic restorations which are highly expensive. At most times, its use is not rightly justified. A case of a 53-year-old female patient, who reported to the Department of Prosthodontics and Crown 8 Bridge, Manipal College of Dental Sciences, Manipal, is presented here where simple and economic restorative techniques and principles are undertaken to achieve predicable esthetic results. How to cite this article George VT. Management of Failed Long-span Single-piece Fixed Prosthesis with Metal—Ceramic Crowns and Cantilever Bridge with Predictable Esthetic Outcome. World J Dent 2016;7(3):162-166.

1 April 2017 in World Journal of Dentistry
Verified
Journal Article
Closed access
DBDhanasekar Balakrishnan
Dhanasekar Balakrishnan
VGVinu Thomas George
Vinu Thomas George
TDTanuka Dutta
Tanuka Dutta
ANAparna Ichalangod Narayan
Aparna Ichalangod Narayan
Introduction: The ultimate success of fixed prosthesis is to pay meticulous attention to the detailed production of the missing tooth structure. Such an accurate replication is technically demanding. Hence, the aim of the study was to evaluate the accuracy of marginal fit of castings with varying sprue diameter and using ring and ringless techniques. Materials and methods: Forty standardized wax copings were fabricated on a stainless steel die and divided into two groups. The first group was cast using the metal ring investment technique; the second group was cast using the ringless investment technique. Both the groups were further divided into two groups, each based on the diameter of the sprue (groups I and III: 4.5 mm and groups II and IV: 2.5 mm). The vertical marginal gap was measured at three sites per specimen, using a digital optical microscope at ×100 magnification. The results were analyzed using two-way analysis of variance and independent t-test to determine statistical significance. Results: The vertical marginal gaps of castings fabricated using the ringless technique (0.145 ± 0.072 mm) were significantly less (p < 0.001) than those castings fabricated using the conventional metal ring technique (0.264 ± 0.100 mm); however, the vertical marginal gaps of the 2.5 mm sprue diameter (0.199 ± 0.092 mm) and 4.5 mm sprue diameter (0.211 ± 0.118 mm) castings were not statistically significant (p > 0.05). There was also statistically significant interaction (p < 0.001) between group IIA (0.120 ± 0.038 mm) and group IA (0.302 ± 0.098 mm), which was analyzed using the independent t-test. Conclusion: It can be concluded that the ringless casting technique in comparison to metal ring technique produces metal castings of better marginal adaptation. Furthermore, the sprue diameter had significant difference wherein the 4.5 mm diameter produced the least vertical discrepancies in the ringless casting technique and 2.5 mm produced lesser vertical discrepancies in the metal ring. Clinical significance: One of the key factors that decides the success of a metal-ceramic restoration is the marginal fit. The accurate fit of the restoration greatly minimizes the plaque accumulation, offers good mechanical properties, and reduces micro-leakage and development of secondary caries. The techniques of casting procedure and sprue diameter can have an influence on the outcome. Hence, the current research was undertaken to study the influence of these factors on marginal fit. How to cite this article: Dutta T, George VT, Balakrishnan D, Narayan AI. An in vitro Comparative Study to evaluate the Marginal Fit of Castings using Ring and Ringless Casting Techniques with Varying Sprue Diameter. World J Dent 2017;8(2):109-113.