Waqas Ali

Mr. Waqas Ali

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2024 in Electronics
Verified
Journal Article
Open access
PDF file
Waqas AliWaqas Ali
Waqas Ali
NNN. Nizam-Uddin
N. Nizam-Uddin
Wazie M. AbdulkawiWazie M. Abdulkawi
Wazie M. Abdulkawi
Asad MasoodAsad Masood
Asad Masood
AHAli Hassan
Ali Hassan
MKMunezza Ata Khan
Munezza Ata Khan
The role of antennas in wireless communication is critical for enabling efficient signal transmission and reception across various frequency bands, including those associated with IoT (Internet of Things), X-band, S-band, and RFID (radio-frequency identification) systems. This paper presents a small quadruple-band antenna with 25 × 40 × 1.5 mm3 dimensions designed for diverse wireless applications. It is adept at operating in the S-band (2.2 GHz), wireless local area network (WLAN) (5.7 GHz), microwave RFID frequency band (5.8 GHz), and X-band (7.7 GHz and 8.3 GHz). While the majority of existing research focuses on antennas covering two or three bands, our work stands out by achieving quad-band operation in the proposed antenna design. This antenna is constructed on a semiflexible Rogers RT5880 substrate, making it well-suited for wearable applications. Computer Simulation Technology (CST) Microwave studio (2019) simulation package software is chosen for design and analysis. The antenna design features a comb-shaped radiating structure, where each “tooth” is responsible for resonating at a distinct frequency with an appropriate bandwidth. The antenna retains stability in both free space and on-body wearability scenarios. It achieves a low specific absorption rate (SAR), meeting wearable criteria with SAR values below 1.6 W/Kg for all resonating frequencies. The proposed antenna demonstrates suitable radiation efficiency, reaching a maximum of 82.6% and a peak gain of 6.3 dBi. It exhibits a bidirectional pattern in the elevation plane and omnidirectional behavior in the azimuth plane. The antenna finds applications across multiple frequencies and shows close agreement between simulated and measured results, validating its effectiveness.

6 August 2025 in IEEE Access
Verified
Journal Article
Open access
Waqas AliWaqas Ali
Waqas Ali
NUNizam- Uddin
Nizam- Uddin
MUHAMMAD ZAHIDMUHAMMAD ZAHID
MUHAMMAD ZAHID
Sultan ShoaibSultan Shoaib
Sultan Shoaib
Real-time tracking, together with monitoring and data collection of human body signals, happens through RFID technology amalgamated with wearable electronics called wearable RFID sensors. Modern sensors find placement in clothing items as well as accessories, and they also operate beneath the skin. The sensors serve several applications across healthcare monitoring, together with asset tracking and security system functions. This article delivers an extensive examination of body-area RFID antenna design issues regarding operating frequencies with biological tissue effects and antenna performance, together with safety compliance aspects. A multicomponent antenna system works as an RFID shield and functions for Bluetooth along with Wi-Fi (2.4 GHz), and includes temperature and sweat sensors for healthcare distance monitoring. The designed antenna spans 600 MHz (2.2–2.8 GHz) within its 25 × 40 × 1.5 mm3 dimensions. This antenna finds optimal application in wearable systems because it utilizes semi-flexible Rogers RT5880 substrate material. The system obtains miniaturized dimensions through the implementation of two E-shaped slots, which allow the device to operate in the desired frequency range. Stability characteristics allow the antenna to operate properly near human bodies and meet the SAR safety requirements of 1.6 W/kg at its operating frequency. Realistic performance tests produced efficient results close agreement between simulated and measured data, thus validating the design potential as a remote healthcare monitoring solution.

1 June 2020
Verified
Conference Paper
Closed access
Waqas AliWaqas Ali
Waqas Ali
MUHAMMAD ZAHIDMUHAMMAD ZAHID
MUHAMMAD ZAHID
SSSultan Shoaib
Sultan Shoaib
MQMuhammad Ali Qureshi
Muhammad Ali Qureshi
AHAshiq Hussain
Ashiq Hussain
Millimeter-wave technology is getting very popular nowadays for fifth-generation (5G) communications due to increased data rate and bandwidth. The world radio conference 2015 by International Telecommunication Union (ITU) has allocated the band 81 GHz to 86 GHz for mobile applications on a primary basis. This work presents a very compact tapered plumb shaped patch antenna for the applications in a higher band (which covers 80.99 GHz to 84.95 GHz for $\text{VSWR} < 2$ and 74.9 GHz to 86.2 GHz for $\text{VSWR} < 3$ ) of 5G with a gain (maximum 7.14 dBi at the resonance frequency of 83.2 GHz and it is more significant than 1.72 dBi in the overall band for $\text{VSWR} < 3$ ), and the total efficiency at resonance frequency is 93.64%. To realize a high gain and to cover the assigned bandwidth of 5 GHz, the partial ground technique is applied, instead of using a fully grounded patch. The proposed compact antenna will be the key element of automotive radar (vehicular communication) and future generation applications.

29 November 2022
Verified
Conference Paper
Closed access
Asad MasoodAsad Masood
Asad Masood
NUN. Nizam Uddin
N. Nizam Uddin
MTMuhammad Hassan Talal
Muhammad Hassan Talal
MRMalik Ehtisham Rabbani
Malik Ehtisham Rabbani
MPMaria Perveen
Maria Perveen
Waqas AliWaqas Ali
Waqas Ali
In this paper, a multiband wearable antenna is proposed capable of operating at ISM (2.4-2.5 GHz), S-band (2.0-4.0 GHz) and WiFi (5.1 GHz) bands. The antenna is designed on the Kapton Polymide flexible substrate having a thickness of 1 mm and overall dimension of 38 × 42 mm 2 . The design of the anticipated antenna is derived from the conventional microstrip patch antenna and is simulated using electromagnetic solver CST Studio Suite 2019. The specific absorption rate (SAR) is evaluated on a three-layer cylindrical phantom. Keeping an input power of 25 mW, the maximum SAR 1g values obtained are 0.075, 0.0535 and 0.028 W/Kg at frequencies of 2.48, 3.9 and 5.1 GHz respectively. The achieved SAR 1g values are well below the FCC limit of 1.6 W/Kg averaged over 1g for human tissue. Antenna demonstrates resonance amplitude well below -10 dB and efficiency greater than 60 %.

10 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Waqas AliWaqas Ali
Waqas Ali
NUNizam Uddin
Nizam Uddin
UUUBAID ULLAH
UBAID ULLAH
MUHAMMAD ZAHIDMUHAMMAD ZAHID
MUHAMMAD ZAHID
Sultan ShoaibSultan Shoaib
Sultan Shoaib
This paper proposes a small size meander-line patch antenna which is designed to have biomedical telemetry applications using the Industrial, Scientific and Medical (ISM) band from 2.40 to 2.48 GHz supported by the equivalent circuit model (ECM). Antenna miniaturization is realized by the effective use of several slot structures placed in the rectangular microstrip patch structure, in order to realize electrical length extension and reduce the physical size. The antenna has overall dimensions of 12 × 22 × 0.787 mm3 and is made on a low-loss Arlon AD 450 (εr = 4.50 and tanδ = 0.0035) dielectric substrate, which has the desired stable electrical behavior and, importantly, can be used in implantable environments. Experimental validation is done by implanting the fabricated prototype into a laboratory-manufactured tissue-mimicking phantom, and it showed good agreement with simulated results. The designed antenna has a peak gain of 1.29 dBi in free space and −24.99 dBi at a frequency of 2.45 GHz and a fractional impedance bandwidth of about 250 MHz, which will guarantee reliable operation in the face of diversity and fluctuation in the surrounding environment (biological tissues). Furthermore, specific absorption rate (SAR) analysis is carried out in order to comply with international safety standards with peak SAR values kept within the permissible level of 2 W/kg for 10 g averaging tissue. The results show that the proposed antenna provides a good trade-off between the reduction in size, radiation performance and safety to the patient, making it a good candidate for short-range in-body wireless communication, implantable medical devices, and biomedical monitoring systems.

12 May 2026 in IEEE Access
Verified
Journal Article
Open access
Waqas AliWaqas Ali
Waqas Ali
NNN. Nizam-Ud-Din
N. Nizam-Ud-Din
MUHAMMAD ZAHIDMUHAMMAD ZAHID
MUHAMMAD ZAHID
Sultan ShoaibSultan Shoaib
Sultan Shoaib
Radio Frequency Identification (RFID) technology has become a critical enabling technology of automatic identification and data capture (AIDC) systems, and has many uses in supply chain management, healthcare monitoring, access control systems, wearable electronics and Internet of Things (IoT) environments. This literature review covers a broad and critical review of the research related to the field of design, development, and testing of a radio-frequency identification tag antenna that is supported by the findings obtained from a thorough analysis of about 90 peer-reviewed journal articles published in the last six years, which covers the technical coverage of the articles, as well as the current relevance. This review presents a systematic investigation of the design methodology of antenna, topologies of antenna, techniques for performance enhancement considerations of the antenna, consideration of materials in antenna, and the emerging research trends in antenna. Special emphasis is placed on important issues such as miniaturization of antennas, improvement of impedance bandwidth, radiation efficiency and the environmental sensitivity due to the proximity to metallic and lossy objects. Furthermore, some research gaps and open challenges are explicitly identified and highlighted according to the surveyed literature so as to give clear ways for future research. For better clarity and to ease comparative analysis, a graphical abstract and several graphical opposing trade-offs and evolving design strategies are consolidated in this review article.