Yuki Nagamatsu

Dr. Yuki Nagamatsu

Biomaterials, Kyushu Dental University, Kitakyushu, Japan
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2021 in Polymers
Verified
Journal Article
Open access
PDF file
KHKentaro Hata
Kentaro Hata
HIHiroshi Ikeda
Hiroshi Ikeda
YNYuki Nagamatsu
Yuki Nagamatsu
CMChihiro Masaki
Chihiro Masaki
RHRyuji Hosokawa
Ryuji Hosokawa
HSHiroshi Shimizu
Hiroshi Shimizu
Poly(methyl methacrylate) (PMMA) is widely used in dental applications. However, PMMA specialized for stereolithography (SLA) additive manufacturing (3D-printing) has not been developed yet. This study aims to develop a novel PMMA-based resin for SLA 3D-printing by mixing methyl methacrylate (MMA), ethylene glycol dimethacrylate (EGDMA), and PMMA powder in various mixing ratios. The printability and the viscosity of the PMMA-based resins were examined to determine their suitability for 3D-printing. The mechanical properties (flexural strength and Vickers hardness), shear bond strength, degree of conversion, physicochemical properties (water sorption and solubility), and cytotoxicity for L929 cells of the resulting resins were compared with those of three commercial resins: one self-cured resin and two 3D-print resins. EGDMA and PMMA were found to be essential components for SLA 3D-printing. The viscosity increased with PMMA content, while the mechanical properties improved as EGDMA content increased. The shear bond strength tended to decrease as EGDMA increased. Based on these characteristics, the optimal composition was determined to be 30% PMMA, 56% EGDMA, 14% MMA with flexural strength (84.6 ± 7.1 MPa), Vickers hardness (21.6 ± 1.9), and shear bond strength (10.5 ± 1.8 MPa) which were comparable to or higher than those of commercial resins. The resin’s degree of conversion (71.5 ± 0.7%), water sorption (19.7 ± 0.6 μg/mm3), solubility (below detection limit), and cell viability (80.7 ± 6.2% at day 10) were all acceptable for use in an oral environment. The printable PMMA-based resin is a potential candidate material for dental applications.

9 April 2023 in Polymers
Verified
Journal Article
Open access
PDF file
KHKentaro Hata
Kentaro Hata
YKYuya Komagata
Yuya Komagata
YNYuki Nagamatsu
Yuki Nagamatsu
CMChihiro Masaki
Chihiro Masaki
RHRyuji Hosokawa
Ryuji Hosokawa
HIHiroshi Ikeda
Hiroshi Ikeda
Poly-ether-ether-ketone (PEEK) is commonly employed in dental prostheses owing to its excellent mechanical properties; however, it is limited by its low bond strength with dental resin cement. This study aimed to clarify the type of resin cement most suitable for bonding to PEEK: methyl methacrylate (MMA)-based resin cement or composite-based resin cement. For this purpose, two MMA-based resin cements (Super-Bond EX and MULTIBOND II) and five composite-based resin cements (Block HC Cem, RelyX Universal Resin Cement, G-CEM LinkForce, Panavia V5, and Multilink Automix) were used in combination with appropriate adhesive primers. A PEEK block (SHOFU PEEK) was initially cut, polished, and sandblasted with alumina. The sandblasted PEEK was then bonded to resin cement with adhesive primer according to the manufacturer’s instructions. The resulting specimens were immersed in water at 37 °C for 24 h, followed by thermocycling. Subsequently, the tensile bond strengths (TBSs) of the specimens were measured; the TBSs of the composite-based resin cements after thermocycling were found to be zero (G-CEM LinkForce, Panavia V5, and Multilink Automix), 0.03 ± 0.04 (RelyX Universal Resin Cement), or 1.6 ± 2.7 (Block HC Cem), whereas those of Super-Bond and MULTIBOND were 11.9 ± 2.6 and 4.8 ± 2.3 MPa, respectively. The results demonstrated that MMA-based resin cements exhibited stronger bonding to PEEK than composite-based resin cements.

3 March 2021 in Materials
Verified
Journal Article
Open access
PDF file
YKyohei kawajiri
yohei kawajiri
HIHiroshi Ikeda
Hiroshi Ikeda
YNYuki Nagamatsu
Yuki Nagamatsu
CMChihiro Masaki
Chihiro Masaki
RHRyuji Hosokawa
Ryuji Hosokawa
HSHiroshi Shimizu
Hiroshi Shimizu
Polymer infiltrated ceramic network (PICN) composites are an increasingly popular dental restorative material that offer mechanical biocompatibility with human enamel. This study aimed to develop a novel PICN composite as a computer-aided design and computer-aided manufacturing (CAD/CAM) block for dental applications. Several PICN composites were prepared under varying conditions via the sintering of a green body prepared from a silica-containing precursor solution, followed by resin infiltration. The flexural strength of the PICN composite block (107.8–153.7 MPa) was similar to a commercial resin-based composite, while the Vickers hardness (204.8–299.2) and flexural modulus (13.0–22.2 GPa) were similar to human enamel and dentin, respectively. The shear bond strength and surface free energy of the composite were higher than those of the commercial resin composites. Scanning electron microscopy and energy dispersive X-ray spectroscopic analysis revealed that the microstructure of the composite consisted of a nanosized silica skeleton and infiltrated resin. The PICN nanocomposite block was successfully used to fabricate a dental crown and core via the CAD/CAM milling process.

Verified
Journal Article
Open access
PDF file
KHKentaro Hata
Kentaro Hata
HIHiroshi Ikeda
Hiroshi Ikeda
YNYuki Nagamatsu
Yuki Nagamatsu
CMChihiro Masaki
Chihiro Masaki
RHRyuji Hosokawa
Ryuji Hosokawa
HSHiroshi Shimizu
Hiroshi Shimizu
Poly(methyl methacrylate) (PMMA)-based resins have been conventionally used in dental prostheses owing to their good biocompatibility. However, PMMA-based resins have relatively poor mechanical properties. In the present study, a novel nanoporous silica filler was developed and introduced into PMMA-based resins to improve their mechanical properties. The filler was prepared by sintering a green body composed of silica and an organic binder, followed by grinding to a fine powder and subsequent silanization. The filler was added to photocurable PMMA-based resin, which was prepared from MMA, PMMA, ethylene glycol dimethacrylate, and a photo-initiator. The filler was characterized by scanning electron microscopy (SEM), X-ray diffraction analysis, nitrogen sorption porosimetry, and Fourier transform infrared (FT-IR) spectroscopy. The PMMA-based resins were characterized by SEM and FT-IR, and the mechanical properties (Vickers hardness, flexural modulus, and flexural strength) and physicochemical properties (water sorption and solubility) were evaluated. The results suggested that the filler consisted of microparticles with nanopores. The filler at 23 wt % was well dispersed in the PMMA-based resin matrix. The mechanical and physicochemical properties of the PMMA-based resin improved significantly with the addition of the developed filler. Therefore, such filler-loaded PMMA-based resins are potential candidates for improving the strength and durability of polymer-based crown and denture base.

25 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
JTJumpei Tokunaga
Jumpei Tokunaga
HIHiroshi Ikeda
Hiroshi Ikeda
YNYuki Nagamatsu
Yuki Nagamatsu
SAShuji Awano
Shuji Awano
HSHiroshi Shimizu
Hiroshi Shimizu
Polymer-infiltrated ceramic network materials (PICNs) have high mechanical compatibility with human enamel. However, the wear properties of PICN against natural human enamel have not yet been clarified. We investigated the in vitro two-body wear behaviors of PICNs and an enamel antagonist. Two PICNs were used: Experimental PICN (EXP) prepared via the infiltration of methacrylate-based resin into the porous silica ceramic network and commercial Vita Enamic (ENA). Two commercial dental ceramics, lithium disilicate glass (LDS) and zirconia (ZIR), were also characterized, and their wear performance was compared to PICNs. The samples were subjected to Vickers hardness tests and two-body wear tests that involve the samples being cyclically impacted by enamel antagonists underwater at 37 °C. The results reveal that the Vickers hardness of EXP (301 ± 36) was closest to that of enamel (317 ± 17). The volumetric wear losses of EXP and ENA were similar to those of LDS but higher than that of zirconia. The volumetric wear loss of the enamel antagonist impacted against EXP was moderate among the examined samples. These results suggest that EXP has wear behavior similar to that of enamel. Therefore, PICNs are mechanically comparable to enamel in terms of hardness and wear and are excellent tooth-restoration materials.

26 July 2019 in Dental Materials Journal
Verified
Journal Article
Open access
PDF file
HMHirotake Miyahara
Hirotake Miyahara
HIHiroshi Ikeda
Hiroshi Ikeda
Yuki FujioYuki Fujio
Yuki Fujio
SYShinji Yoshii
Shinji Yoshii
YNYuki Nagamatsu
Yuki Nagamatsu
HSHiroshi Shimizu
Hiroshi Shimizu
The goal of this study was to investigate the chemical alteration of a dental alloy surface by alumina air-abrasion and its effect on bonding to resin cement. Alumina air-abrasion was carried out on an Ag-Pd-Cu-Au alloy. The surface morphology and chemical state of the abraded alloy were characterized. The effect of the air-abrasion on the shear bond strength between the alloy and a methyl methacrylate/tri-n-butyl borane (MMA/TBB) resin cement with some primers was evaluated. The surface characterization revealed that the alumina air-abrasion mechanically roughened and chemically altered the surface. The chemical alterations had two effects: (1) abraded alumina particles remained on the alloy surface and (2) copper ions were oxidized in the alloy surface. As the result, the shear bond strength test indicated that 10-methacryloyloxydecyl dihydrogen phosphate (MDP) contained primer worked with the abraded alloy surface, whereas it did not work with the non-abraded alloy surface.