Yongqiu Zheng

Dr. Yongqiu Zheng

North University of China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
GLGang Li
Gang Li
Juan CuiJuan Cui
Juan Cui
TLTingshan Liu
Tingshan Liu
YZYongqiu Zheng
Yongqiu Zheng
CHCongcong Hao
Congcong Hao
CXChenyang Xue
Chenyang Xue
Wind energy as a renewable energy source is easily available and widely distributed in cities. However, current wind-energy harvesters are inadequate at capturing energy from low-speed winds in urban areas, thereby limiting their application in distributed self-powered sensor networks. A triboelectric–electromagnetic hybrid harvester with a low startup wind speed (LSWS-TEH) is proposed that also provides output power within a wide range of wind speeds. An engineering-implementable propeller design method is developed to reduce the startup wind speed of the harvester. A mechanical analysis of the aerodynamics of the rotating propeller is performed, and optimal propeller parameter settings are found that greatly improved its aerodynamic torque. By combining the high-voltage output of the triboelectric nanogenerator under low-speed winds with the high-power output of the electromagnetic generator under high-speed winds, the harvester can maintain direct current output over a wide wind-speed range after rectification. Experiments show that the harvester activates at wind speeds as low as 1.2 m/s, powers a sensor with multiple integrated components in 1.7 m/s wind speeds, and drives a Bluetooth temperature and humidity sensor in 2.7 m/s wind speeds. The proposed small, effective, inexpensive hybrid energy harvester provides a promising way for self-powered requirements in smart city settings.

23 July 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RLRui Liang
Rui Liang
HZHongtian Zhu
Hongtian Zhu
XZXiang Zhu
Xiang Zhu
MGMaocheng Guo
Maocheng Guo
QZQi Zhang
Qi Zhang
CXChenyang Xue
Chenyang Xue
A fiber optic high-temperature pressure dual parametric sensor utilizing femtosecond laser technology based on the Vernier effect is proposed, demonstrated, and experimentally validated for gas pressure and temperature monitoring in high-temperature environments. The sensor features two parallel Fabry-Pérot interferometers (FPIs) and a fiber Bragg grating (FBG). Each FPI is fabricated using femtosecond laser-induced water breakdown and arc discharge techniques, serving as the sensing FPI and the reference FPI, respectively. These FPIs have closely matched free spectral ranges, producing the traditional Vernier effect to enhance pressure sensitivity. Additionally, an FBG prepared with femtosecond laser technology is cascaded in front of the sensing FPI to measure gas temperature and compensate for pressure variations. The sensor was validated by a two-parameter experiment at 700°C and 5 MPa. At room temperature (24.7°C), the gas pressure sensitivity of this sensor is approximately 18.66 nm/MPa, which is about 4.7 times greater than that of a single sensing FPI. At a high temperature of 700°C, the gas pressure sensitivity is approximately 6.09 nm/MPa. The temperature sensitivity of the FBG for temperature measurement is 12.4 pm/°C. The sensor exhibits a maximum full-scale pressure error of 5.68% across the entire temperature range, utilizing the FBG to measure gas temperature and compensate for pressure sensitivity. This sensor demonstrates high temperature resistance and high pressure sensitivity, making it suitable for gas temperature-pressure dual parameter monitoring in high-temperature environments. Additionally, it is easy to fabricate and exhibits robustness, sensitivity, and reliability.

31 August 2018 in Optics Communications
Verified
Journal Article
Closed access
PDF file
CZChengfei Zhang
Chengfei Zhang
ZPZiwen Pan
Ziwen Pan
YZYongqiu Zheng
Yongqiu Zheng
PAPanlong An
Panlong An
JTJun Tang
Jun Tang
JLJun Liu
Jun Liu

19 September 2024 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
XZXinyu Zhao
Xinyu Zhao
XRXiwang Ren
Xiwang Ren
JBJiandong BAI
Jiandong BAI
YZYongqiu Zheng
Yongqiu Zheng
YYYang Yang
Yang Yang
CXChenyang Xue
Chenyang Xue
The sensors capable of measuring a wide range of pressures at high temperatures are critically needed in the industrial fields. We propose an optical fiber tip probe pressure sensor based on Fabry-Pérot interferometer (FPI). This sensor is fabricated by splicing single-mode, multimode, and hollow-core fibers using arc discharge technology. Pressure is detected by demodulating the change in cavity length of the FPI. Experimental results show that the sensor's pressure sensitivity can reach −9.81 nm/MPa within a pressure range of 0–12 MPa. It maintains excellent optical properties from 20 to 1100 °C, exhibiting a temperature sensitivity of 0.33 nm/°C. To enhance pressure measurement precision at high temperatures, a fiber Bragg grating is integrated into the FPI structure for temperature sensing and error correction. The simplicity and stability of the proposed sensor make it suitable for reliable gas pressure measurements in high-temperature environments.

15 April 2025 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
JBJiandong BAI
Jiandong BAI
SCShengjie Cao
Shengjie Cao
HCHaoyan Chai
Haoyan Chai
YZYongqiu Zheng
Yongqiu Zheng
CXChenyang Xue
Chenyang Xue
Fiber optic Fabry-Pérot (F-P) interferometric sensors have been widely applied in various industries, because it can sense multiple physical quantities such as pressure, vibration, and refractive index by changing its cavity length. Therefore, it is very important to get the accurate and effective cavity length information. Traditional demodulation techniques for F-P cavity suffer from low speed, high cost, and poor robustness. Here, we propose a novel ultrahigh-speed demodulation system for F-P interferometric sensors based on the spatio-temporal features of sparse spectra. This system employs a combination of a dense wavelength division multiplexer, multi-channel photodetector, and analog-to-digital converter to acquire sparse spectra at high speed. Two neural network models are trained to extract the spectral temporal and spatial features, enabling ultrahigh-speed high-resolution demodulation for the changes of the cavity length and wide-range stable demodulation for absolute cavity length. The system has a demodulation rate of up to 500 kHz and a cavity length change resolution at the nm scale. It also supports the demodulation for absolute cavity length over a wide range of 15–950 $\mu$m. And it remains stable after six hours of continuous testing. Therefore, the ultrahigh-speed wide-range demodulation system offers a novel, cost-effective, and reliable solution for engineering field, showcasing significant potential for applications in high-speed fiber optic sensing.

15 October 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MGMaocheng Guo
Maocheng Guo
QZQi Zhang
Qi Zhang
ZSZhixuan Su
Zhixuan Su
HZHongtian Zhu
Hongtian Zhu
RLRui Liang
Rui Liang
CXChenyang Xue
Chenyang Xue
An optical fiber Fabry-Pérot interferometer (FPI) sensor offering simultaneous measurement of temperature and pressure is proposed. This sensor is constructed by fusion splicing a single mode fiber-hollow core Bragg fiber-single mode fiber (SMF-HCBF-SMF) structure. The HCBF serves as a pressure-sensitive unit on which gas channels are realized by femtosecond laser machining. The last segment of the SMF serves as a temperature-sensitive unit. The Fast Fourier Transform-Minimum Mean Square Error (FFT-MMSE) algorithm demodulates the sensor’s optical cavity lengths to realize the temperature and pressure measurement in the temperature range of 25~600°C. Experiments demonstrate that the sensor exhibits high linearity. The sensor’s pressure sensitivity decreases as temperature increases. At 25°C and 600°C, the pressure sensitivities are 158.3 nm/MPa and 51.9 nm/MPa, and the temperature sensitivity is 3.8 nm/°C. The pressure full-scale error is only 4% across the entire temperature range when using the temperature-pressure decoupling calculation method. The high temperature and high sensitivity characteristics of the proposed sensor highlight its potential for monitoring gas pressure in extremely high-temperature environments.