Karolina Dudek

Dr. Karolina Dudek

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
KDKarolina Dudek
Karolina Dudek
Mateusz DulskiMateusz Dulski
Mateusz Dulski
BŁBożena Łosiewicz
Bożena Łosiewicz
The surface modification of NiTi shape memory alloys is a method for increasing their multi-functionalities. In our solution, hydroxyapatite powder was mixed with a chemically synthesized silicon dioxide/silver (nSiO2/Ag) nanocomposite in a different weight ratio between components (1:1, 5:1, and 10:1) and then electrophoretically deposited on the surface of the NiTi alloy, under various time and voltage conditions. Subsequently, uniform layers were subjected to heat treatment at 700 °C for 2 h in an argon atmosphere to improve the strength of their adhesion to the NiTi substrate. A change in linear dimensions of the co-deposited materials during the sintering process was also analyzed. After the heat treatment, XRD, Raman, and Scanning Electron Microscopy (SEM) + Energy Dispersive Spectrometer (EDS) studies revealed the formation of completely new composite coatings, which consisted of rutile and TiO2-SiO2 glass with silver oxide and HAp particles that were embedded into such coatings. It was found that spalling characterized the 1:1 ratio coating, while the others were crack-free, well-adhered, and capable of deformation to 3.5%. Coatings with a higher concentration of nanocomposite were rougher. Electrochemical impedance spectroscopy (EIS) tests in Ringer’s solution revealed the capacitive behavior of the material with high corrosion resistance. The kinetics and susceptibility to pitting corrosion was the highest for the NiTi electrode that was coated with a 5:1 ratio HAp/nSiO2/Ag hybrid coating.

16 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
BŁBożena Łosiewicz
Bożena Łosiewicz
ASAgnieszka Stróż
Agnieszka Stróż
POPatrycja Osak
Patrycja Osak
JMJoanna Maszybrocka
Joanna Maszybrocka
AGAnna Gerle
Anna Gerle
SBSylwia Bogunia
Sylwia Bogunia
This work concerns the development of a method of functionalization of the surface of the biomedical Ti–6Al–7Nb alloy by producing oxide nanotubes (ONTs) with drug-eluting properties. Shaping of the morphology, microstructure, and thickness of the oxide layer was carried out by anodization in an aqueous solution of 1 M ethylene glycol with the addition of 0.2 M NH4F in the voltage range 5–100 V for 15–60 min at room temperature. The characterization of the physicochemical properties of the obtained ONTs was performed using SEM, XPS, and EDAX methods. ONTs have been shown to be composed mainly of TiO2, Al2O3, and Nb2O5. Single-walled ONTs with the largest specific surface area of 600 cm2 cm−2 can be obtained by anodization at 50 V for 60 min. The mechanism of ONT formation on the Ti–6Al–7Nb alloy was studied in detail. Gentamicin sulfate loaded into ONTs was studied using FTIR, TG, DTA, and DTG methods. Drug release kinetics was determined by UV–Vis spectrophotometry. The obtained ONTs can be proposed for use in modern implantology as carriers for drugs delivered locally in inflammatory conditions.

Verified
Journal Article
Open access
PDF file
Mateusz DulskiMateusz Dulski
Mateusz Dulski
RGRobert Gawecki
Robert Gawecki
Slawomir SulowiczSlawomir Sulowicz
Slawomir Sulowicz
MCMichal Cichomski
Michal Cichomski
AKAlicja Kazek-Kęsik
Alicja Kazek-Kęsik
KDKarolina Dudek
Karolina Dudek
Recent years have seen the dynamic development of methods for functionalizing the surface of implants using biomaterials that can mimic the physical and mechanical nature of native tissue, prevent the formation of bacterial biofilm, promote osteoconduction, and have the ability to sustain cell proliferation. One of the concepts for achieving this goal, which is presented in this work, is to functionalize the surface of NiTi shape memory alloy by an atypical glass-like nanocomposite that consists of SiO2-TiO2 with silver nanoparticles. However, determining the potential medical uses of bio(nano)coating prepared in this way requires an analysis of its surface roughness, tribology, or wettability, especially in the context of the commonly used reference coat-forming hydroxyapatite (HAp). According to our results, the surface roughness ranged between (112 ± 3) nm (Ag-SiO2)—(141 ± 5) nm (HAp), the water contact angle was in the range (74.8 ± 1.6)° (Ag-SiO2)—(70.6 ± 1.2)° (HAp), while the surface free energy was in the range of 45.4 mJ/m2 (Ag-SiO2)—46.8 mJ/m2 (HAp). The adhesive force and friction coefficient were determined to be 1.04 (Ag-SiO2)—1.14 (HAp) and 0.247 ± 0.012 (Ag-SiO2) and 0.397 ± 0.034 (HAp), respectively. The chemical data showed that the release of the metal, mainly Ni from the covered NiTi substrate or Ag from Ag-SiO2 coating had a negligible effect. It was revealed that the NiTi alloy that was coated with Ag-SiO2 did not favor the formation of E. coli or S. aureus biofilm compared to the HAp-coated alloy. Moreover, both approaches to surface functionalization indicated good viability of the normal human dermal fibroblast and osteoblast cells and confirmed the high osteoconductive features of the biomaterial. The similarities of both types of coat-forming materials indicate an excellent potential of the silver-silica composite as a new material for the functionalization of the surface of a biomaterial and the development of a new type of functionalized implants.

20 March 2017 in Powder Diffraction
Verified
Journal Article
Closed access
PDF file
KDKarolina Dudek
Karolina Dudek
JPJacek Podwórny
Jacek Podwórny
Mateusz DulskiMateusz Dulski
Mateusz Dulski
ANAnna Nowak
Anna Nowak
JPJ. Peszke
J. Peszke
X-ray diffraction data revealed that the initial SiO 2 /Ag nanocomposite, manufactured in a chemical synthesis process, is mainly composed of silica in amorphous phase (95.5 wt.%), crystalline Ag with a cubic structure ( Fm -3 m ) and cristobalite (SiO 2 ) with a tetragonal structure ( P 4 1 2 1 2) in the amount of 4.2 and 0.3 wt.%, respectively. High-temperature diffraction data revealed high stability of the SiO 2 /Ag composite up to 1000 °C. High-temperature X-ray diffraction measurements revealed phase cristallization temperatures of silica at 1060 °C for cristobalite and 1080 °C for tridymite as well as temperature of silver evaporation starting from the composite (ca. 1000 °C). Infrared spectroscopy data confirmed the presence of amorphous matrix with embedded silver ions and crystalline compounds in the form of cristobalite and tridymite without silver after thermal treatment.

15 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
KDKarolina Dudek
Karolina Dudek
Tomasz GoryczkaTomasz Goryczka
Tomasz Goryczka
Mateusz DulskiMateusz Dulski
Mateusz Dulski
BPBronisław Psiuk
Bronisław Psiuk
ASAGNIESZKA SZURKO
AGNIESZKA SZURKO
ZLZdzisław Lekston
Zdzisław Lekston
To functionalize and improve the biocompatibility of the surface of a medical implant made of NiTi shape memory alloy and used in practice, a clamp, multifunctional layers composed of amorphous TiO2 interlayer, and a hydroxyapatite coating were produced. Electrophoresis, as an efficient method of surface modification, resulted in the formation of a uniform coating under a voltage of 60 V and deposition time of 30 s over the entire volume of the implant. The applied heat treatment (800 °C/2 h) let toa dense, crack-free, well-adhered HAp coating with a thickness of ca. 1.5 μm. and a high crack resistance to deformation associated with the induction of the shape memory effect in the in the deformation range similar to the real implant work after implantation. Moreover, the obtained coating featured a hydrophilic (CA = 59.4 ± 0.3°) and high biocompatibility.

1 October 2015 in Materials Letters
Verified
Journal Article
Closed access
KDKarolina Dudek
Karolina Dudek
MPMateusz Plawecki
Mateusz Plawecki
Mateusz DulskiMateusz Dulski
Mateusz Dulski
JKJerzy Kubacki
Jerzy Kubacki