Agnieszka Stróż

Mrs. Agnieszka Stróż

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in Materials Characterization
Verified
Journal Article
Closed access
ASAgnieszka Stróż
Agnieszka Stróż
BŁBożena Łosiewicz
Bożena Łosiewicz
MZMaciej Zubko
Maciej Zubko
BCB. Chmiela
B. Chmiela
KBKatarzyna Balin
Katarzyna Balin
Tomasz GoryczkaTomasz Goryczka
Tomasz Goryczka

25 April 2021 in Coatings
Verified
Journal Article
Open access
PDF file
Krzysztof AniołekKrzysztof Aniołek
Krzysztof Aniołek
BŁBożena Łosiewicz
Bożena Łosiewicz
JKJulian Kubisztal
Julian Kubisztal
POPatrycja Osak
Patrycja Osak
ASAgnieszka Stróż
Agnieszka Stróż
Sławomir KaptaczSławomir Kaptacz
Sławomir Kaptacz
Titanium and its alloys are among the most promising biomaterials for medical applications. In this work, the isothermal oxidation of Ti-6Al-7Nb biomedical alloy towards improving its mechanical properties, corrosion resistance, and bioactivity has been developed. The oxide layers were formed at 600, 700, and 800 °C for 72 h. Scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), 3D profilometry, and microindentation test, were used to characterize microstructure, surface geometrical structure, and the hardness of the diphase (α + β) Ti-6Al-7Nb alloy after oxidation, respectively. In vitro corrosion resistance tests were carried out in a saline solution at 37 °C using the open-circuit potential method and potentiodynamic measurements. Electronic properties in the air were studied using the Scanning Kelvin Probe (SKP) technique. The bioactivity test was conducted by soaking the alkali- and heat-treated samples in simulated body fluid for 7 days. The presence of apatite was confirmed using SEM/EDS and Fourier Transform Infrared Spectroscopy (FTIR) studies. The thickness of oxide layers formed increased with the temperature growth from 0.25 to 5.48 µm. It was found that with increasing isothermal oxidation temperature, the surface roughness, hardness, corrosion resistance, and contact potential difference increased. The Ti-6Al-7Nb alloy after oxidation revealed the HAp-forming ability in a biological environment.

1 October 2016 in Acta Physica Polonica A
Verified
Journal Article
Closed access
ASAgnieszka Stróż
Agnieszka Stróż
Grzegorz DerczGrzegorz Dercz
Grzegorz Dercz
BCB. Chmiela
B. Chmiela
DSDanuta Stróż
Danuta Stróż
BŁBożena Łosiewicz
Bożena Łosiewicz

16 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
BŁBożena Łosiewicz
Bożena Łosiewicz
ASAgnieszka Stróż
Agnieszka Stróż
POPatrycja Osak
Patrycja Osak
JMJoanna Maszybrocka
Joanna Maszybrocka
AGAnna Gerle
Anna Gerle
SBSylwia Bogunia
Sylwia Bogunia
This work concerns the development of a method of functionalization of the surface of the biomedical Ti–6Al–7Nb alloy by producing oxide nanotubes (ONTs) with drug-eluting properties. Shaping of the morphology, microstructure, and thickness of the oxide layer was carried out by anodization in an aqueous solution of 1 M ethylene glycol with the addition of 0.2 M NH4F in the voltage range 5–100 V for 15–60 min at room temperature. The characterization of the physicochemical properties of the obtained ONTs was performed using SEM, XPS, and EDAX methods. ONTs have been shown to be composed mainly of TiO2, Al2O3, and Nb2O5. Single-walled ONTs with the largest specific surface area of 600 cm2 cm−2 can be obtained by anodization at 50 V for 60 min. The mechanism of ONT formation on the Ti–6Al–7Nb alloy was studied in detail. Gentamicin sulfate loaded into ONTs was studied using FTIR, TG, DTA, and DTG methods. Drug release kinetics was determined by UV–Vis spectrophotometry. The obtained ONTs can be proposed for use in modern implantology as carriers for drugs delivered locally in inflammatory conditions.

Verified
Journal Article
Open access
PDF file
MSMateusz Schabikowski
Mateusz Schabikowski
ASAgnieszka Stróż
Agnieszka Stróż
AKAndrzej Kruk
Andrzej Kruk
Anodised metal matrices represent a versatile and multifunctional platform for the development of advanced materials with tunable physicochemical properties. Through electrochemical oxidation processes—commonly referred to as anodisation—metals such as aluminium, titanium, niobium, zinc and tantalum can be transformed into structured oxide layers with defined porosity, thickness and surface morphology. These methods enable the fabrication of ordered nanoporous arrays, nanotubes and nanowires, depending on the process parameters and the type of metal. The review introduces and outlines the various anodisation techniques and parameters. This is crucial, since each individual metal requires specified optimal conditions to obtain a stable anodised oxide layer. This review provides an overview of recent advances in the design and application of anodised metal substrates, with the focus on their role as functional platforms in catalysis, sensing, energy storage and biomedical engineering. Special attention is given to post-anodisation surface modification strategies, such as chemical functionalisation, thin-film deposition and molecular-level integration, which significantly expand the utility of these materials. The review also highlights the challenges, limitations and future perspectives of anodising technologies, aiming to guide the rational design of next-generation devices based on engineered oxide architectures.

1 March 2015 in Solid State Phenomena
Verified
Journal Article
Closed access
PDF file
BŁBożena Łosiewicz
Bożena Łosiewicz
MPMagdalena Popczyk
Magdalena Popczyk
MSMagdalena Szklarska
Magdalena Szklarska
ASAgnieszka Stróż
Agnieszka Stróż
POPatrycja Osak
Patrycja Osak
ABA. Budniok
A. Budniok
This paper deals with the basic theory and the usability of the scanning Kelvin probe (SKP) being a non-destructive, non-contact method for testing the condition of the surface of conductor, semiconductor and dielectric samples. This technique is based on the electron work function (EWF) characteristic of various test substances and depends, inter alia, on the sample surface condition. During measurement, the so-called surface potential distribution map containing information about EWF value is registered. Key applications of SKP and its various modifications to characterization of corrosion interfaces, have been presented based on the newest literature data covering the past two years of the active research in the field of corrosion in a nanoscale.