Water scarcity poses significant challenges in arid regions like the Middle East and North Africa (MENA) due to constant population growth, considering the effects of climate change and water management aspects. The desalination technologies face problems like high energy consumption, high investment costs, and significant environmental impacts by brine discharge. This paper researches the relationships among water scarcity, energy-intensive desalination, and the development of renewable energy in MENA, with a particular focus on the Gulf Cooperation Council (GCC) countries. It examines innovations in solar-powered desalination, considering both solar photovoltaic (PV) and solar thermal technologies, in combination with traditional thermal desalination methods such as multi-effect distillation (MED) and multi-stage flash (MSF). The environmental impacts associated with desalination by brine discharge are also discussed, analyzing innovative technological solutions and avoidance strategies. Utilizing bibliometrics, this report provides a comprehensive analysis of scientific literature for the assessment of the research landscape in order to recognize trends in desalination technologies in the MENA region, providing valuable insights into emerging technologies and research priorities. Despite challenges such as high initial investment costs, technical complexities, and limited funding for research and development, the convergence of water scarcity and renewable energy presents significant opportunities for integrated desalination systems in GCC countries. Summarizing, this paper emphasizes the importance of interdisciplinary approaches and international collaboration by addressing the complex challenges of water scarcity and energy sustainability in the MENA region. By leveraging renewable energy sources and advancing desalination technologies, the region can achieve water security while mitigating environmental impacts and promoting economic development.
Water scarcity remains the major looming challenge that is facing Jordan. Wastewater reclamation is considered as an alternative source of fresh water in semi-arid areas with water shortage or increased consumption. In the present study, the current status of wastewater reclamation and reuse in Jordan was analyzed considering 30 wastewater treatment plants (WWTPs). The assessment was based on the WWWTPs’ treatment processes in Jordan, the flowrates scale, and the effluents’ average total dissolved solid (TDS) contents. Accordingly, 60% of the WWTPs in Jordan used activated sludge as a treatment technology; 30 WWTPs were small scale (<1 × 104 m3/day); and a total of 17.932 million m3 treated wastewater had low TDS (<1000 ppm) that generally can be used in industries with relatively minimal cost of treatment. Moreover, the analysis classified the 26 million m3 groundwater abstraction by major industries in Jordanian governorates. The results showed that the reclaimed wastewater can fully offset the industrial demand of fresh water in Amman, Zarqa, and Aqaba governorates. Hence, the environmental assessment showed positive impacts of reclaimed wastewater reuse scenario in terms of water depletion (saving of 72.55 million m3 groundwater per year) and climate change (17.683 million kg CO2Eq reduction). The energy recovery assessment in the small- and medium-scale WWTPs (<10 × 104 m3/day) revealed that generation of electricity by anaerobic sludge digestion equates potentially to an offset of 0.11–0.53 kWh/m3. Finally, several barriers and prospects were put forth to help the stakeholders when considering entering into an agreement to supply and/or reuse reclaimed water.
Periodic daily fluctuating demand for energy and power is a perceptible phenomenon, resulting in some moments of low demand for power and energy related to the huge energy comes from renewable energy systems, and some moments of peak load demand. This phenomenon, when combined with the non-stationary operation of huge capacity of renewable energy systems, results in no stability of voltage and frequency. To assure continuous network stability and to avoid energy losses from renewable energy systems that are subject to such control system, a hybrid system with energy–power storage in the form of pumped-hydro storage is considered the most suitable technically. This paper presents the design, modeling, analysis, and feasibility study of a hybrid wind and water-pumping storage system. The system was designed and analyzed for King Talal Dam (KTD), which is in Northern Jordan. The importance of this study is that it is directed mainly to Jordan and the Middle East and North Africa (MENA) region in general. The Jordanian renewable energy market is a promising arena that encourages developers, investors, engineers, and companies to develop and install pure renewable energy systems and renewable energy hybrid projects for the generation of electricity. The analysis of wind data is carried out using the “windfarm” software with 5.16 m/s as average wind speed. It is followed by the design of the hybrid system, which is simulated for a daily operation of 2–3 h as peak load hours. Based on the technical outcomes, cost study and feasibility analyses are carried out with Jordanian market prices. The total estimated annual energy production is 26,663,933 kWh from 10 MW wind farm and 5.2 MW pumping storage system. The aforementioned studies showed that a similar hybrid system is not always fully commercially feasible. However, a pure pumped-storage system proved to be technically feasible and assisting the grid. The whole project analysis determines that such a system boosts the operational stability of the grid, increases the penetration of renewable energy systems and reduces the energy import. In addition, 15,100,000 tons of CO2-equivalent is estimated as annual emissions reduction in this study.
Anaerobic digestion for biomethane production is an important tool regarding sustainable energy production. The objective of this study was to investigate the effects of the substrate composition and operating parameters on biomethane production during anaerobic digestion, focusing on the use of flotates and slaughterhouse waste as substrates with a high organic content. A novelty here was the use of a moving bed biofilm reactor (MBBR) with circulation pump for the anaerobic treatment of flotates, slaughter waste (SW), and their mixture. Flotates and waste from slaughterhouses offer a substrate with a high organic content. In this work, it was shown that both substrates provide a high biochemical methane potential (BMP). The highest methane yield was achieved by mixing both substrates. In continuous operation, special challenges arose, due to the high nitrogen and fat content of the substrates. These could be overcome by mixing the substrates and using a circulation pump in the reactor for improved back-mixing. As a result, the highest average methane yield of 0.65 NLCH4·gTS eli−1 was achieved in mesophilic operation at an organic loading rate (OLR) of 4.2 gTS·L−1·d−1.
Air conditioning is becoming increasingly important in the energy supply of buildings worldwide. There has been a dramatic increase in energy requirements for cooling buildings in the Middle East and North Africa (MENA) region. This is before taking the effects of climate change into account, which will also entail a sharp increase in cooling requirements. This paper presents the potential of using a solar thermal absorption cooling system in Sub-Mediterranean Climate. Four sites in Jordan are now equipped with water-lithium bromide (H2O-LiBr) absorption chillers with a total nominal capacity of 530 kW. The focus of the paper was on the pilot system at the German Jordanian University (GJU) campus with a cooling capacity of 160 kW. The system was designed and integrated in order to support two existing conventional compression chillers with a nominal cooling capacity of 700 kW. The system was economically evaluated based on the observed cooling capacity results with a Coefficient of Performance (COP) equals 0.32, and compared with the values observed for a COP of 0.79 which is claimed by the manufacturer. Several techniques were implemented to evaluate the overall economic viability in-depth such as present worth value, internal rate of return, payback period, and levelized cost of electricity. The aforementioned economic studies showed that the absorption cooling system is deemed not feasible for the observed COP of 0.32 over a lifespan of 25 years. The net present value was equal to −137,684 JD and a payback period of 44 years which exceeds the expected lifespan of the project. Even for an optimal operation of COP = 0.79, the discounted payback period was equal to 23 years and the Levelized Cost of Electricity (LCOE) was equal to 0.65 JD/kWh. The survey shows that there are several weaknesses for applying solar thermal cooling in developing countries such as the high cost of these systems and, more significantly, the lack of experience for such systems.