The deteriorating water environment demands new approaches and technologies to achieve sustainable and smart management of urban water systems. Wireless sensor networks represent a promising technology for water quality monitoring and management. The use of wireless sensor networks facilitates the improvement of current centralized systems and traditional manual methods, leading to decentralized smart water quality monitoring systems adaptable to the dynamic and heterogeneous water distribution infrastructure of cities. However, there is a need for a low-cost wireless sensor node solution on the market that enables a cost-effective deployment of this new generation of systems. This paper presents the integration to a wireless sensor network and a preliminary validation in a wastewater treatment plant scenario of a low-cost water quality monitoring device in the close-to-market stage. This device consists of a nitrate and nitrite analyzer based on a novel ion chromatography detection method. The analytical device is integrated using an Internet of Things software platform and tested under real conditions. By doing so, a decentralized smart water quality monitoring system that is conceived and developed for water quality monitoring and management is accomplished. In the presented scenario, such a system allows online near-real-time communication with several devices deployed in multiple water treatment plants and provides preventive and data analytics mechanisms to support decision making. The results obtained comparing laboratory and device measured data demonstrate the reliability of the system and the analytical method implemented in the device.
A method using zinc powder in conjunction with the common Griess assay was developed for the detection of nitrate in water. This method is applicable to portable water test kits and allows for the accurate determination of nitrate in freshwater. The linear range for the method was shown to be 0.5–45 mg L−1 NO3− and the limit of detection (LOD) was 0.5 mg L−1 NO3−. The proposed method was validated over a five-day period and acceptable recovery and uncertainties were achieved when analysing freshwater matrices. The performance of the developed method was compared to an ISO-accredited ion chromatographic (IC) method by carrying out blind sample analysis. A good agreement between the two methods was achieved as comparable concentrations were determined using each method. In addition, the Zn method was compared to the performance of a novel solid-phase reagent method, previously developed within the group. The most accurate performance was demonstrated by the Zn powder method when analysing freshwater samples. The novel solid-phase reagent method demonstrated the greater accuracy when analysing seawater samples.