In this paper a comparison of the wideband power sources of a pulse width modulation (PWM) inverter and a power supply composed of an audio power amplifier and a two-channel arbitrary generator is discussed. Their application is to supply a step-up current transformer for generation of the distorted current required to test the transformation accuracy of the distorted currents of the inductive current transformers. The proposed equations allow to calculate the maximum rms values of higher harmonic of distorted currents for its required main harmonic component. Moreover, they also enable the calculation of the maximum rms values of the main harmonic of the distorted current for which the required higher harmonic component may be obtained. This defines the usable bandwidth of the tested power source for their specific load. During work on high inductive impedance, the maximum voltage is the limitation that determines the higher harmonic value. While for resistive loads, the maximum current and the transistor’s slew rate are the limiting factors. The usage of the compensation system for the inductive reactance of the step-up current transformer under supply significantly increased its maximum output current. Its rms value with a 10% higher harmonic component up to 5 kHz was almost 400 A instead 100 A for the PWM-based power source and about 800 A instead 200 A for the power supply system with the audio amplifier.
The paper presents investigations and analysis of the parameters of the magnetic part of the equivalent circuit of the inductive CT in the frequencies range from 50 Hz to 5 kHz. Therefore, a measuring circuit used to determine the values of the transverse branch elements was developed. The research performed helps to understand the obtained values of the frequency characteristics of the current error and phase displacement of the corrected inductive current transformer. Moreover, the vectorial diagrams for the 1st, 20th and 100th harmonics are provided with consideration of the influence of the applied turns number correction of the secondary winding. The obtained results show that the increase in the frequency of transformed higher harmonics may cause a decrease in the values of the current error and phase displacement for the non-corrected inductive current transformer. However, if the number of turns of the secondary winding is corrected, the behavior is reversed, where the values of the current error are higher with increased frequency. In the paper, the influence of the self-generation phenomenon of the low-order harmonics is also considered.
Inductive current transformers are characterized by different transformation accuracies for higher harmonics of distorted primary currents. Therefore, it is highly required to perform the tests of their metrological properties to choose the best unit that ensures the lowest values of current error and phase displacement. This study presents a comparison of two manufactured inductive current transformers. The results indicate that some inductive current transformers may be used to accurately transform distorted currents, enabling proper distortion of power metering and quality evaluation. However, to obtain adequate transformation properties in the wide frequency range, the cross-section of the magnetic core of the inductive current transformer should be oversized. Moreover, it is required to use a permalloy magnetic core instead of the typical transformer steel core. In the analyzed case, the metrological performance depends mainly on its accuracy for transforming the main component of the distorted primary current and self-generation of the low-order higher harmonics. This paper constitutes the starting point to define the limiting values of current error and phase displacement for the future wideband accuracy class extension for inductive CTs.
In this paper the results of the EMC tests of the wideband power sources: the PWM-based power source and audio power amplifier are discussed. They are intended to be used to supply the measuring system developed for evaluation of the wideband transformation accuracy of instrument transformers. Therefore, it is required to detect possible interferences that may be caused by the power supply to its operation and that may cause a decrease in its accuracy. The tests concern the conducted emission in the frequencies range from 150 kHz to 30 MHz and the radiated emission in the frequencies range from 30 MHz to 1 GHz. Moreover, the level of conducted disturbances in frequencies range from 100 Hz to 5 kHz generated into the supplying current is measured and the immunity of both wideband power sources to low frequency conductive disturbances in the supplying voltage and current is tested. Then, the voltage gain error and phase shift of the output voltage are measured. The EMC tests of both power sources show lack of compliance with the requirement of the standard IEC 61326-1. However, in system application of the audio power amplifier is possible if required increased immunity to conducted emission of the measuring system is ensured.
The aim of this paper is to show that the developed inductive current transformer may ensure the required wideband transformation accuracy and it may be applied, as the reference source, in the measuring system for the evaluation of the transformation accuracy of inductive current transformers for harmonics of distorted current. This device ensures 5 A and 1 A RMS secondary currents to provide the opportunity to use the differential measuring setup. Such solutions are characterized by the significantly reduced measurement uncertainty in relation to the comparative measurements made between two current/voltage channels. The problems required to ensure the high wideband transformation accuracy, including the self-generation phenomenon of the low order higher harmonics to the secondary current and a too-low frequency range of operation, were overcome in the design process. The values of its ratio error and the phase displacement of the developed reference wideband inductive current transformer did not exceed ±0.2%/° up to 1 kHz, ±0.4%/° from 1 kHz up to 1.5 kHz and ±0.5%/° from 1.5 kHz up to 3 kHz, as is required to perform the test procedure in accordance with the optional requirements for the inductive current transformers defined in the new edition of the standard IEC 61869-1.
In this paper, we present an investigation into the influence of the load power factor of secondary winding on the metrological performance of inductive CTs with frequencies from 50 Hz to 5 kHz of the harmonic of a transformed distorted current. The results clearly indicated that the inductive load caused a deterioration in the transformation accuracy of the inductive CT. To ensure the most advantageous conditions of their operation, a resistive load should be used. The inductive CTs for the frequencies of the transformed harmonic of a distorted primary current from 50 Hz to 5 kHz may ensure the accuracy class designated for the transformation of the sinusoidal current of a frequency of 50 Hz with the same limiting values of errors. Moreover, an analysis of the generated low-order harmonics by a 300 A/5 A CT determined for the power factor of 0.8 inductive and 1.0 of the secondary winding was investigated. These results for the transformed distorted currents of 3rd, 5th and 7th higher harmonics were evaluated for a rated load and 25% of this value.