Overvoltage transients occur after any type of switching activity in a power network, such as breaker operation, fault occurrence/clearance and rapid load change. This distortion of voltage is transformed to the secondary circuit of a voltage transformer. The maximum values of such impulses may many times exceed the rated value of its secondary voltage. This can lead to malfunction of measuring or protection devices connected to the secondary circuit of a voltage transformer and even their damage. The paper presents the application of determined values of ratio error at harmonics of the inductive voltage of the transformer to predict the value of transformed slow-front transient overvoltage to their secondary circuits. This will help to prevent malfunction of measuring or protection devices connected to the secondary side of the voltage transformer and increase their safety of operation. The inductive voltage transformer equivalent circuit for transformation of higher frequency components of distorted voltage must be extended with internal capacitances of windings. This is caused by the fact that the resonance phenomenon of the slow-front transient overvoltage results from leakage inductance and capacitance of primary winding, not from the magnetic core. Therefore, this behaviour is independent from the value of the applied voltage.
In this paper the results of the EMC tests of the wideband power sources: the PWM-based power source and audio power amplifier are discussed. They are intended to be used to supply the measuring system developed for evaluation of the wideband transformation accuracy of instrument transformers. Therefore, it is required to detect possible interferences that may be caused by the power supply to its operation and that may cause a decrease in its accuracy. The tests concern the conducted emission in the frequencies range from 150 kHz to 30 MHz and the radiated emission in the frequencies range from 30 MHz to 1 GHz. Moreover, the level of conducted disturbances in frequencies range from 100 Hz to 5 kHz generated into the supplying current is measured and the immunity of both wideband power sources to low frequency conductive disturbances in the supplying voltage and current is tested. Then, the voltage gain error and phase shift of the output voltage are measured. The EMC tests of both power sources show lack of compliance with the requirement of the standard IEC 61326-1. However, in system application of the audio power amplifier is possible if required increased immunity to conducted emission of the measuring system is ensured.
Short transient states during interruptions and dips of the supply voltage of the voltage transformer are the cause of low power quality and source of impulsive conductive disturbances which are transferred to secondary side of the voltage transformer. Maximal values of these impulses are able to exceed even several times rated rms values of primary and secondary voltages. This may lead to abnormal operation of measuring and protection apparatus connected to the secondary side of voltage transformer or even to their damage. In this article used methods of measurements for calculation of the factor of transfer of impulsive disturbances from primary to secondary sides of voltage transformer are presented as well as results of analysis of the influence of construction parameters of windings and their operation conditions on the amount and quality of this transfer.
1 December 2011 in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
Operation of voltage transformer in grids with distorted signals: Non-sinusoidal currents and voltages caused by nonlinear loads appear in power grids more and more frequently. Determination of the voltage transformer accuracy in such conditions makes a problem. Firstly, due to lack of definition of errors for distorted signals and secondly, typical measurement bridges do not accept higher harmonics. In the paper, the new definition of transformation error for distorted voltages has been proposed and some measurement results have been presented.
The article presents problems related to the measurement methods of radiated radioelectric disturbances emitted by light sources (eg LED) defined by EN55015 standard. Smaller trustworthiness of the use of the CDN method have been noted, which is an alternative method to the methods of measuring emissions in shielded chambers (eg GTEM). Presented are the results of the radiated emission test of selected LED lamps regarding the described problem.
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.