A study of indoor environmental quality inside the old (naturally ventilated) and new (air-conditioned) train cabins and platforms of four main stations of the Athens subway system (Attiko Metro), took place in different two-day measurements from June to August 2012. Portable instrumentation provided continuous measurements of particulate matter (PM10, PM2.5 and PM1), carbon dioxide (CO2) along with temperature (T) and absolute humidity (AH). PM concentrations were significantly higher on the underground platforms of the network from 3 to 10 times, as compared to outdoor measurements. In particular, mean PM1, PM2.5 and PM10 concentrations at the deeper and most crowded station of Syntagma reached 18.7, 88.1 and 320.8 μg m−3 respectively. On the contrary, the ground level, open station of the Airport, showed values comparable to the outdoor (2, 6.4 and 34.4 μg m−3, respectively). All PM fractions were lower than the platforms inside the old and new train cabins while the air conditioned trains experienced lower particulate pollution levels. More specifically, mean PM1, PM2.5 and PM10 concentrations were 5.5, 16.8and 58.3 μg m−3, respectively in new cabins while in the old they reached 10.3, 47.5 and 238.8 μg m−3. The PM2.5/PM10 and PM1/PM2.5 ratios did not exceed 0.33 on both platforms and trains verifying the dominance of crustal coarse particles originating from the train and ground materials. As expected CO2 levels were higher inside the trains as compared to the platforms and in some cases surpassed the 1000 ppm limit during the hottest days of the experimental campaign. Temperature and humidity remained relatively stable on the platforms, whereas measurements inside the cabins fluctuated, depending on the type of train and track locations. Correlations between measured PM along the routes to and from the Airport indicated covariance of concentrations along train cabins of the same direction.
The coronavirus disease 2019 (COVID-19), which is mainly transmitted through droplets without overlooking other sources of transmission, rendered attention on the air quality in indoor areas and more specifically in healthcare settings. The improvement of indoor air quality (IAQ) is ensured by frequent changes of the air that must be carried out in healthcare areas and with assistance from special devices that undertake the filtration of the air and its purification through special filters and lamps. In this research, the performance of air purifiers is assessed in terms of the limitation of PM2.5, PM10, VOCs and CO2 in a postgraduate clinic of the Dentistry School of the National and Kapodistrian University of Athens in parallel with mechanical ventilation. Our findings indicate that the use of mechanical ventilation plays a key role on the results, retaining good IAQ levels within the clinic and that air purifiers show a positive impact on IAQ by mainly reducing the levels of PM2.5 and secondly of TVOC.
This paper presents experimental results from a typical school building in Athens, equipped partly with a green roof system (GRS). Environmental monitoring took place in six classrooms located both under the concrete roof and the GRS sectors as well as in the immediate external environment during the warm and cold periods of a school year. Daily measurements of pollutants CO2, TVOCs (Total Volatile Organic Compound), PM1, PM2.5, and PM10 were performed in selected classes. Moreover, indoor ambient temperature (T) and relative humidity (RH) measurements were implemented in order to estimate the absolute humidity (AH) and assess the indoor environmental conditions. The results highlight that during summer, the GRS reduces temperature in a classroom on the top floor by about 2.8 °C, in comparison with the respective classroom under the concrete roof and that AH remained relatively stable for both classrooms. Amid winter, a reverse behavior occurs only for temperature. Moreover, air exchange rates (AER) were calculated by using the CO2 decay method for all of the classrooms. The results demonstrated insufficient ventilation for all experimental sights. Finally, concentrations of PM1, PM2.5 and PM10, were found to be relatively decreased, with average values of 0.79, 3.39, and 27.80 μg m−3. Levels of CO2 and TVOCs were elevated during class hours ranging from 469 to 779 ppm and from 6.63 ppm to 13.33 ppm, respectively, but generally within the respective limits of exposure. The examination of the indoor/outdoor (I/O) ratio of air pollutants, demonstrated that the outdoor meteorology affects only PM1 and PM2.5, as PM10 and TVOCs are strongly affected by internal sources and the activities of pupils.
In the following years all European Union member states should bring into force national laws on the energy performance of buildings. Moreover, university campus dormitories are buildings of great importance, due to their architectural characteristics and their social impact. In this study, the energy performance along with the indoor environmental conditions of a dormitory of a university has been analysed. The in situ measurements included temperature, relative humidity, concentrations of carbon dioxide, total volatile organic compounds, and electrical consumption; lastly, the energy signature of the whole building was investigated. The study focused on the summer months, during which significantly increased thermal needs of the building were identified. The ground floor was found to be the floor with the highest percentage of thermal conditions within the comfort range, and the third floor the lowest. Lastly, a significant correlation between electrical consumption and the outdoor temperature was presented, highlighting the lack of thermal insulation. Overall, it was clear that a redesign of the cooling and heating system, the installation of a ventilation system, and thermal insulation are essential for improving the energy efficiency of this building.
On a European scale, the existing building stock has poor energy performance and particularly vulnerable structures. Indeed, most of the existing buildings were built before the introduction of energy standards and under structural safety criteria different from those currently required. It is therefore necessary the intervention in existing buildings according to an integrated approach that contemplates both the structural safety and the energy efficiency of buildings. This study, consistently with the objectives of the European research project “Proactive synergy of integrated Efficient Technologies on buildings’ Envelopes (Pro-GET-OnE)”, proposes a retrofit intervention for a student dormitory of the National and Kapodistrian University of Athens. The scope of the evaluation is to understand how an integrated intervention, that implies a structural and energy retrofit, as well as a spatial redistribution, leads to an improvement of the Indoor Environmental Quality (IEQ). In detail, the structural retrofit was performed through exoskeleton that leads to the addition of new living spaces and to a remodeling of the building facades. The energy retrofit regarded all three levers of energy efficiency, and thus the building envelope, the microclimatic control systems, and the systems from renewable sources. The integrated intervention, in addition to a reduction of energy demand, has led to advantages in terms of IEQ. Thermal comfort, both during summer and winter, is improved and the hours of suitable CO2 concentration pass from 34% in the pre-retrofit stage up to 100% in the post retrofit stage.