Robert Piec

Dr. Robert Piec

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2022 in Environmental Science and Pollution Research
Verified
Journal Article
Open access
PDF file
JOJoanna Orysiak
Joanna Orysiak
Magdalena MłynarczykMagdalena Młynarczyk
Magdalena Młynarczyk
RPRobert Piec
Robert Piec
AJAgnieszka Jakubiak
Agnieszka Jakubiak
Health status depends on multiple genetic and non-genetic factors. Nonheritable factors (such as lifestyle and environmental factors) have stronger impact on immune responses than genetic factors. Firefighters work is associated with exposure to air pollution and heat stress, as well as: extreme physical effort, mental stress, or a changed circadian rhythm, among others. All these factors can contribute to both, short-term and long-term impairment of the physical and mental health of firefighters. Increased levels of some inflammatory markers, such as pro-inflammatory cytokines or C-reactive protein (CRP) have been observed in firefighters, which can lead to local, acute inflammation that promotes a systemic inflammatory response. It is worth emphasizing that inflammation is one of the main hallmarks of cancer and also plays a key role in the development of cardiovascular and respiratory diseases. This article presents possible causes of the development of an inflammatory reaction in firefighters, with particular emphasis on airway inflammation caused by smoke exposure.

25 November 2020 in Minerals
Verified
Journal Article
Open access
PDF file
Mariusz GusiatinMariusz Gusiatin
Mariusz Gusiatin
JKJurate Kumpiene
Jurate Kumpiene
SJSylwia Janiszewska
Sylwia Janiszewska
Slawomir KasinskiSlawomir Kasinski
Slawomir Kasinski
MPMariusz Pecio
Mariusz Pecio
Maja RadziemskaMaja Radziemska
Maja Radziemska
Ash from poultry feather gasification was investigated as an adsorbent for Cd removal from synthetic wastewater under a range of operational conditions: initial pH (2–8) and salinity (8–38 mS/cm) of wastewater, ash dosage (2.5–50 g/L), Cd concentration (25–800 mg/L) and contact time (5–720 min). The ash was highly alkaline and had low surface area and micropores averaging 1.12 nm in diameter. Chemical/mineralogical analysis revealed a high content of P2O5 (39.9 wt %) and CaO (35.5 wt %), and the presence of calcium phosphate, hydroxyapatite and calcium. It contained only trace amounts of heavy metals, BTEX, PAHs and PCBs, making it a safe mineral by-product. Cd adsorption was described best with Langmuir and pseudo-second order models. At pH 5, an ash dosage of 5 g/L, 40 min contact time and 100 mg Cd/L, 99% of Cd was removed from wastewater. The salinity did not affect Cd sorption. The maximum adsorption capacity of Cd was very high (126.6 mg/g). Surface precipitation was the main mechanism of Cd removal, possibly accompanied by ion exchange between Cd and Ca, coprecipitation of Cd with Ca-mineral components and Cd complexation with phosphate surface sites. Poultry ash effectively removes high concentrations of toxic Cd from wastewater.

22 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
DPDaniel Pieniak
Daniel Pieniak
AWAgata Walczak
Agata Walczak
MOMarcin Oszust
Marcin Oszust
Krzysztof PrzystupaKrzysztof Przystupa
Krzysztof Przystupa
RKRenata Kamocka-Bronisz
Renata Kamocka-Bronisz
Dariusz UlbrichDariusz Ulbrich
Dariusz Ulbrich
The article presents results of experimental studies on mechanical properties of the polymer-composite material used in manufacturing firefighting helmets. Conducted studies included static and impact strength tests, as well as a shock absorption test of glass fiber-reinforced polyamide 66 (PA66) samples and firefighting helmets. Samples were subject to the impact of thermal shocks before or during being placed under a mechanical load. A significant influence of thermal shocks on mechanical properties of glass fiber-reinforced PA66 was shown. The decrease in strength and elastic properties after cyclic heat shocks ranged from a few to several dozen percent. The average bending strength and modulus during the 170 degree Celsius shock dropped to several dozen percent from the room temperature strength. Under these thermal conditions, the impact strength was lost, and the lateral deflection of the helmet shells increased by approximately 300%. Moreover, while forcing a thermal shock occurring during the heat load, it was noticed that the character of a composite damage changes from the elasto-brittle type into the elasto-plastic one. It was also proved that changes in mechanical and elastic properties of the material used in a helmet shell can affect the protective abilities of a helmet.

3 June 2020 in medRxiv
Verified
Preprint
Open access
PDF file
Kamil AdamczykKamil Adamczyk
Kamil Adamczyk
MHMichał Herman
Michał Herman
JFJanusz Frączek
Janusz Frączek
RPRobert Piec
Robert Piec
BPBarbara Szykula - Piec
Barbara Szykula - Piec
EFEdward Franek
Edward Franek
Objective: to quantitatively assess disturbances of sweet, sour and salty and bitter tastes in a group of young, asymptomatic or oligosymptomatic COVID-19 patients; establish a reliable, sensitive and specific test that can diagnose COVID-19 on the basis of taste disorders and publish the results according to STARD 2015 statement (Standards for Reporting Diagnostic Accuracy). Design: case-control study Setting: isolated rooms in the Central Clinical Hospital of the Ministry of the Interior and Administration in Warsaw (which had been transformed into an infectious hospital) and a dormitory in one of Warsaw universities. Participants: 52 SARS-CoV-2 positive (51 men, mean age 21.7 years) and 36 negative students (34 men, mean age 20.8 years). Main outcome measures: a gustatory function assessment (sweet, salty, sour and bitter taste), with flavour concentrations established previously in healthy subjects was conducted for all subjects. Each participant received one tasteless reference and nine flavour tablets with sucrose concentrations of 40, 80 and 106.4 mg/ml; NaCl at 13.5, 17 and 27 mg/ml; ascorbic acid at 6.25 and 12.5 mg/ml and grapefruit extract at 40 mg/ml. Results: the only taste that was impaired significantly more frequently in COVID-19 patients was the sweet taste at the lowest flavour concentration (40 mg/ml, p = 0.002). Different screening and diagnostic models were constructed using the examined variables. The highest accuracy screening test consisted of the positive result of a three-question questionnaire (self-reported loss of taste, self-reported loss of smell, or fever within the last month (positive if at least one present) and/or ageusia of sweet taste at a sucrose concentration of 40 mg/ml. The sensitivity of the model was 94% with a specificity of 55%. The highest accuracy diagnostic test consisted of ageusia of sweet taste at a sucrose concentration of 106.4 mg/ml or/and ageusia of salty taste at an NaCl concentration of 13.5 or 17 mg/ml. The specificity of the test was found to be 100%, and the sensitivity was 34%. Conclusion: as the most effective way of controlling the present pandemic involves testing the wider population for symptomatic, oligosymptomatic and asymptomatic carriers of SARSCoV-2 and isolating or hospitalising infected subjects, in the present study, an inexpensive, simple, fast and sensitive (94%) screening test that can be used for such a purpose is proposed. In addition, a specific (100%) diagnostic test that could be used to refer patients to quarantine in the case of limited availability of genetic or serological tests is proposed.

BKBozena Kukfisz
Bozena Kukfisz
AKAneta Kuczyńska
Aneta Kuczyńska
RPRobert Piec
Robert Piec
BPBarbara Szykula - Piec
Barbara Szykula - Piec
Many countries lack clear legal requirements on the distance between buildings and petrol station facilities. The regulations in force directly determine the petrol station facilities’ required distance to buildings, and such distances are considered relevant for newly designed and reconstructed buildings. Public buildings must be located no closer than 60 m to the above-ground liquefied gas tanks and liquid gas dispensers. Still, based on engineering calculations and the applied technical measures, it is possible to determine a safe distance for buildings that are constructed, extended and reconstructed, to which superstructures are added or whose utilisation method changes. The paper presents the results of calculations devoted to determining a safe distance between public buildings and LPG filling station facilities, using selected analytical models. The analyses were carried out for the LPG gas system commonly used in petrol stations, consisting of two gas storage tanks of 4.85 m3 capacity each, and a dispenser. It is legitimate to eliminate the obligation to observe the 60 m distance between LPG filling stations and public buildings and the mandatory distance of 60 m between liquefied gas dispensers and public buildings is not justified in light of the implemented requirements to use various protections at self-service liquefied gas filling stands.

15 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
TWTomasz Węsierski
Tomasz Węsierski
RPRobert Piec
Robert Piec
MMMałgorzata Majder-Łopatka
Małgorzata Majder-Łopatka
BKBernard Król
Bernard Król
WGWiktor Gawroński
Wiktor Gawroński
MKMarek Kwiatkowski
Marek Kwiatkowski
The publication presents the results of a field test of 2–4 min releases of 96% LNG from a road tanker designed to carry the gas. The release was performed at a pressure of 5.9–6.1 atm at a discharge rate of 1.67–1.78 kg/s from a height of 0.75 m under class B conditions of atmospheric stability. Comparison of the obtained experimental results of the maximum concentrations and the simulation carried out with the EFFECS (11.2.0) software showed that the Gaussian gas model better describes the gas cloud propagation at most control points at this release intensity than the dense gas model. The dense gas model gave only slightly better results along the cloud propagation axis at close distances, not exceeding 25/30 m at ground level. It is shown that concentrations between 71% and 110% LEL are observed at the cloud visibility limit. The maximum value of the temperature drop, in the release axis, at a distance of 4 m amounts to ∆Tmax = 93.3 °C. This indicates that the cloud of the released LNG is almost entirely in the vapour state already in the short distance from the point of release, due to the turbulent outflow of the pressurised gas.