Małgorzata Majder-Łopatka

Dr. Małgorzata Majder-Łopatka

Institute of Safety Engineering, The Main School of Fire Service, 52/54 Slowackiego Street, 01-629 Warsaw, Poland
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2008 in Environmental Pollution
Verified
Journal Article
Closed access
LDLukasz Drewniak
Lukasz Drewniak
ASAleksandra Styczek
Aleksandra Styczek
MMMałgorzata Majder-Łopatka
Małgorzata Majder-Łopatka
ASAleksandra Sklodowska
Aleksandra Sklodowska

1 October 2020 in Building and Environment
Verified
Journal Article
Closed access
WRWioletta Anna Rogula-Kozłowska
Wioletta Anna Rogula-Kozłowska
KBKarolina Bralewska
Karolina Bralewska
PRPatrycja Rogula-Kopiec
Patrycja Rogula-Kopiec
RMRadosław Makowski
Radosław Makowski
MMMałgorzata Majder-Łopatka
Małgorzata Majder-Łopatka
Grzegorz MajewskiGrzegorz Majewski
Grzegorz Majewski

18 December 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
MMMałgorzata Majder-Łopatka
Małgorzata Majder-Łopatka
TWTomasz Węsierski
Tomasz Węsierski
ADAnna Dmochowska
Anna Dmochowska
ZSZdzisław Salamonowicz
Zdzisław Salamonowicz
Andrzej PolanczykAndrzej Polanczyk
Andrzej Polanczyk
This article examines electrochemical carbon monoxide (CO) sensors used as mobile devices by rescue and firefighting units in Poland. The conducted research indicates that the presence of chlorine (Cl2), ammonia (NH3), hydrogen sulfide (H2S), hydrogen chloride (HCl), hydrogen cyanide (HCN), nitrogen (IV) oxide (NO2), and sulfur (IV) oxide (SO2) in the atmosphere does not affect the functioning of the electrochemical CO sensor. In the case of this sensor, there was a significant cross effect in relation to hydrogen (H2). It was found that the time and manner of using the sensor affects the behavior in relation to H2. Such a relationship was not recorded for CO. Measurements in a mixture of CO and H2 confirm the effect of hydrogen on the changes taking place inside the sensor. Independently of the ratio of H2 to CO, readings of CO were flawed. All analyses showed a significant difference between the electrochemical CO sensor readings and the expected values. Only in experiments with a 1:3 mixture of CO and H2 was the relative error less than 15%. The relative error in the analyzed concentration range for a sensor with an additional compensation electrode ranged from 7% to 38%; for a sensor without this electrode, it ranged from 23% to 55%. It was ascertained that in the cases of measurements for tests carried out at higher concentrations of H2 in relation to CO, a sensor with an additional electrode is significantly better (more accurate) than a sensor without such an electrode. Differences at the significance level p = 0.01 for measurements made in the CO:H2 mixture at a ratio of 1:3 were ascertained.

29 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
MMMałgorzata Majder-Łopatka
Małgorzata Majder-Łopatka
TWTomasz Węsierski
Tomasz Węsierski
AAArtur Ankowski
Artur Ankowski
KRKamil Ratajczak
Kamil Ratajczak
DDDominik Duralski
Dominik Duralski
Andrzej PolanczykAndrzej Polanczyk
Andrzej Polanczyk
Fires in landfills, where used plastic packaging waste is discarded, have shown how great a fire hazard these types of materials pose. In this study, the course of thermo-oxidation of samples made of polypropylene (PP), polystyrene (PS), and polyethylene terephthalate (PET) based plastics was determined. Based on an analysis of the dissociation energy of bonds between atoms in a polymer molecule, the mechanisms responsible for the character and course of degradation were observed. It was found that the degradation rate of PP and PS could be a result of the stability of C-H bonds on the tertiary carbon atom. In the case of PS, due to facilitated intramolecular hydrogen transfer, stabilization of hydroperoxide, and formation of a stable tertiary alcohol molecule, the onset of degradation is shifted towards higher temperatures than in the case of PP. Notably, the PP fragmentation occurs to a greater extent due to the easier course of β-scission. In addition, it was found that during a fire, the least amount of heat would be generated by thermo-oxidation of PS-based plastics. This is a result of the formation of a styrene molecule during decomposition that, due to the high stability of bonds in the aromatic ring, escapes from the combustion zone without oxidation. It has been proven that the greatest thermal effect accompanies PET decomposition, during which a phenyl radical is produced, where the C-H bonds break more easily in comparison with the bonds of an intact ring.

Grzegorz MajewskiGrzegorz Majewski
Grzegorz Majewski
KWKamila Widziewicz-Rzońca
Kamila Widziewicz-Rzońca
WRWioletta Anna Rogula-Kozłowska
Wioletta Anna Rogula-Kozłowska
Patrycja Rogula-KopiecPatrycja Rogula-Kopiec
Patrycja Rogula-Kopiec
KKKarolina Kociszewska
Karolina Kociszewska
MNMariusz Niemczyk
Mariusz Niemczyk
This study assessed inhalation exposure to particulate matter (PM1)-bound mercury (Hgp) and PM1-bound polycyclic aromatic hydrocarbons (PAHs) among university students. For this purpose, simultaneous indoor (I) and outdoor (O) measurements were taken from two Polish technical universities (in Gliwice and Warsaw) located in distinct areas with respect to ambient concentrations and major sources of PM. The indoor geometric mean concentrations of Hgp were found to be 1.46 pg·m−3 and 6.38 pg·m−3 in Warsaw and Gliwice, while the corresponding outdoor concentrations were slightly lower at 1.38 pg·m−3 and 3.03 pg·m−3, respectively. A distinct pattern was found with respect to PAH concentrations with estimated I/O values of 22.2 ng·m−3/22.5 ng·m−3 in Gliwice and 10.9 ng·m−3/11.12 ng·m−3 in Warsaw. Hazard quotients (HQs) as a result of exposure to Hgp for students aged 21 ranged from 3.47 × 10−5 (Warsaw) to 1.3 × 10−4 (Gliwice) in terms of reasonable maximum exposure (RME). The non-cancer human health risk value related to Hgp exposure was thus found to be below the acceptable risk level value of 1.0 given by the US EPA. Daily exposure values for lecture hall occupants, adjusted to the benzo(a)pyrene (BaP) toxicity equivalent (BaPeq), were 2.9 and 1.02 ng·m−3 for the Gliwice and Warsaw students, respectively. The incremental lifetime cancer risk (ILCR) values with respect to exposure to PM1-bound PAHs during the students’ time of study were 5.49 × 10−8 (Warsaw) and 1.43 × 10−7 (Gliwice). Thus, students’ exposure to indoor PAHs does not lead to increased risk of lung cancer.

3 July 2018 in E3S Web of Conferences
Verified
Conference Paper
Open access
MMMałgorzata Majder-Łopatka
Małgorzata Majder-Łopatka
WRWioletta Anna Rogula-Kozłowska
Wioletta Anna Rogula-Kozłowska
WWWiktor Wąsik
Wiktor Wąsik
Fourier-transform infrared spectroscopy (FT-IR) enables the passive detection and identification of chemical agent clouds from distances. It can be used for the monitoring of large spaces and protection of industrial installations outside buildings. The aim of the study was show the possibilities and limitations of passive FT-IR. In studies done by the Faculty of Fire Safety Engineering at the Main School of Fire Service were used spectrometer RAPID (Remote Air Pollution Infrared Detector), Bruker Daltonics Company. Hazardous substances such as acetone, methanol, ammonia was identified on-line from several observation points at 25 m, 50 m and 75 m. The tests were carried out at various meteorological conditions. The results indicate that remote infrared detection allows detecting hazardous chemical agents in the atmosphere from a distance. Nevertheless, meteorological and terrain conditions have a big impact on the measurement results. During measurements, the detector indicated the presence of other substances. Moreover, it was found that under cloudy and windy weather, remote detection is not possible.