Marc Berger

Dr. Marc Berger

Leibniz University Hannover, Hanover, Germany
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2017 in Analytical Chemistry
Verified
Journal Article
Closed access
ABAlexander Bohnhorst
Alexander Bohnhorst
AKAnsgar T. Kirk
Ansgar T. Kirk
Marc BergerMarc Berger
Marc Berger
SZStefan Zimmermann
Stefan Zimmermann

1 October 2019
Verified
Conference Paper
Closed access
Marc BergerMarc Berger
Marc Berger
FSFlora Sellering
Flora Sellering
HRHannes Röhrich
Hannes Röhrich
HMHussam Mansour
Hussam Mansour
TPThorsten Perl
Thorsten Perl
SZStefan Zimmermann
Stefan Zimmermann
During dialysis treatment with individual sodium profiles, in which the dialysate sodium concentration is changed over time and consequently the blood sodium concentration, continuous monitoring of the sodium blood concentration is important. The current practice is to analyze blood samples in the laboratory or using a blood gas analyzer. This way, quasi-continuous monitoring requires a considerable amount of personnel effort and costs. Moreover, the results are just available with a time delay. In this paper, we present a low-cost PCB differential transformer for continuous and contactless monitoring of the sodium concentration in blood during dialysis treatment. The PCB differential transformer monitors the conductivity of blood as a measure of the sodium concentration. This is a reasonable approach since the conductivity of blood is mainly defined by the sodium concentration under physiological conditions. In preclinical experiments, we show that the sodium concentration in blood can be measured by this approach with a maximum relative error of 2.7 % referenced to a commercially available blood gas analyzer.

1 October 2020 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Marc BergerMarc Berger
Marc Berger
AZAnne Zygmanowski
Anne Zygmanowski
FSFlora Sellering
Flora Sellering
HRHannes Röhrich
Hannes Röhrich
TPThorsten Perl
Thorsten Perl
SZStefan Zimmermann
Stefan Zimmermann

19 August 2020 in Journal of Sensors and Sensor Systems
Verified
Journal Article
Open access
PDF file
Marc BergerMarc Berger
Marc Berger
MSMerle Sehlmeyer
Merle Sehlmeyer
FSFlora Sellering
Flora Sellering
HRHannes Röhrich
Hannes Röhrich
TPThorsten Perl
Thorsten Perl
SZStefan Zimmermann
Stefan Zimmermann
The individualization of dialysis treatment using a customized dialysate composition usually requires a continuous measurement of electrolytes and urea in blood. The current practices are spot measurements of blood samples either with blood gas analyzers or in the laboratory, involving considerable personnel effort. Furthermore, the measured values are time delayed and not available in a continuous fashion. In this paper we investigate an in-line concept for continuous monitoring of important blood parameters such as sodium, potassium, calcium and urea concentrations in blood serum using ion-selective electrodes. This concept is evaluated in a preclinical study with human packed red blood cells as a test medium over a period of 7 h. It has been shown that the electrolytes can be well monitored. In addition, we present first measurements with ion-sensitive field-effect transistors in a miniaturized sensor assembly. Therefore, new low-cost electronics for such ion-sensitive field-effect transistors have been developed.

29 October 2018 in Journal of Sensors and Sensor Systems
Verified
Journal Article
Open access
PDF file
Marc BergerMarc Berger
Marc Berger
MFMichael Faulstich
Michael Faulstich
TPThorsten Perl
Thorsten Perl
SZStefan Zimmermann
Stefan Zimmermann
One objective of dialysis treatment is to normalize the blood plasma electrolytes and remove waste products such as urea and creatinine from blood. However, due to a shift in plasma osmolarity, a rapid or excessive change of the electrolytes can lead to complications like cardiovascular instability, overhydrating of cells, disequilibrium syndrome and cardiac arrhythmias. Especially for critical ill patients in intensive care unit with sepsis or multi-organ failure, any additional stress has to be avoided. Since the exchange velocity of the electrolytes mainly depends on the concentration gradients across the dialysis membrane between blood and dialysate, it can be controlled by an individualized composition of dialysate concentrations. In order to obtain a precise concentration gradient with the individualized dialysate, it is necessary to continuously monitor the plasma concentrations. However, with in-line sensors, the required hemocompatibility is often difficult to achieve. In this work, we present a concept for continuous in-line monitoring of electrolyte concentrations using ion-selective electrodes separated from the blood flow by a dialysis membrane, and therefore meeting the fluidic requirements for hemocompatibility. First investigations of hemocompatibility with reconfigured human blood show no increased hemolysis caused by the measuring system. With this concept, it is possible to continuously measure the plasma concentrations with a relative error of less than 0.5 %.

1 November 2019 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
EBErik Bunert
Erik Bunert
Marc BergerMarc Berger
Marc Berger
AKAnsgar T. Kirk
Ansgar T. Kirk
SZStefan Zimmermann
Stefan Zimmermann
Ion mobility spectrometers (IMSs) are well-known instruments for fast and ultrasensitive trace gas detection. In recent years, we introduced a compact nonradioactive electron source providing a defined current of free electrons with high kinetic energy at atmospheric pressure for initiating a chemical gas phase ionization of the analytes identical to radioactive sources. Besides its nonradioactivity, one major advantage of this electron source is its controlled electron emission current even in pulsed mode. By optimizing the geometric parameters and developing faster control electronics, we now achieve electron pulses with extremely short pulse widths down to 23 ns. This allows us to kinetically control the formation of reactants and analyte ions by chemical gas phase ionization (e.g., reducing discrimination processes caused by competing ionization), enhancing the analytical performance of the IMS. However, this paper concentrates on the pulsed electron source. For its characterization, we developed a measurement setup, which allows the detection of nanosecond electron pulses with amplitudes of only a few nanoamperes. Furthermore, we investigated the spatial ion distribution in the ionization region depending on several operating parameters, such as the kinetic electron energy or the ionization time.