Sensors for monitoring electrical parameters over an entire electricity network infrastructure play a fundamental role in protecting smart grids and improving the network’s energy efficiency. When a short circuit takes place in a smart grid it has to be sensed as soon as possible to reduce its fault duration along the network and to reduce damage to the electricity infrastructure as well as personal injuries. Existing protection devices, which are used to sense the fault, range from classic analog electro-mechanics relays to modern intelligent electronic devices (IEDs). However, both types of devices have fixed adjustment settings (offline stage) and do not provide any coordination among them under real-time operation. In this paper, a new smart sensor is developed that offers the capability to update its adjustment settings during real-time operation, in coordination with the rest of the smart sensors spread over the network. The proposed sensor and the coordinated protection scheme were tested in a standard smart grid (IEEE 34-bus test system) under different short circuit scenarios and renewable energy penetration. Results suggest that the short-circuit fault sensed by the smart sensor is improved up to 80% and up to 64% compared with analog electromechanics relays and IEDs, respectively.
The increase in the installation of renewable energy sources in electrical systems has changed the power distribution networks, and a new scenario regarding protection devices has arisen. Distributed generation (DG) might produce artificial delays regarding the performance of protection devices when acting as a result of short-circuits. In this study, the preliminary research results carried out to analyze the effect of renewable energy sources (photovoltaic, wind generation, etc.) on the protection devices of a power grid are described. In order to study this problem in a well-defined scenario, a quite simple distribution network (similar to the ones present in rural areas) was selected. The distribution network was divided into three protection zones so that each of them had DG. In the Institute of Electrical and Electronic Engineers (IEEE) system 13 bus test feeder, the short-circuits with different levels of penetration were performed from 1 MVA to 3 MVA (that represent 25%, 50%, and 75% of the total load in the network). In the simulations carried out, it was observed that the installation of DG in this distribution network produced significant changes in the short-circuit currents, and the inadequate performance of the protection devices and the delay in their operating times (with differences of up to 180% in relation to the case without DG). The latter, that is, the impacts of photovoltaic DG on the reactions of protection devices in a radial distribution network, is the most relevant outcome of this work. These are the first results obtained from a research collaboration framework established by staff from ETSI Civil and the IDR/UPM Institute, to analyze the effect of renewable energy sources (as DG) on the protection devices of a radial distribution network.
Silicon is the main element in the composition of glass and it has been seen that it can be used as a partial replacement for cement in the manufacture of concrete. Different dosages of glass powder and cement were applied to manufacture the concrete mixes. Initially, the characteristics of fresh concrete were studied, such as consistency, air content, apparent density and workability. Secondly, compressive strength tests were performed on the different concrete mixtures produced. The consistency tests allowed us to classify these concretes within the group of fluids. The air content of these concretes increased with the rate of substitution of cement by glass powder, resulting in lighter concretes. Density tests showed that this parameter decreased as the rate of substitution of cement increased. A coefficient k has been calculated for the substitution of glass powder by cement in the binder, using the Bolomey formula. Also, a mathematical model has been proposed to further analyze the experimental data. Major contributions of this work were to study the possible application of this concrete in different dispersions as a surface protection layer against the action of corrosion, in wind turbine foundations as well as the stabilization of the wind farm roads.
Electric power distribution networks are generally radial in nature, with unidirectional power flows transmitted from the highest voltage levels to the consumption levels. The protection system in these distribution networks is relatively simple and consists mainly of fuses, reclosers (RC) and overcurrent relays (OCRs). The installation of distributed generation (DG) in a network causes coordination problems between these devices, because the power flows are no longer unidirectional and can flow upstream to the substation. For this reason, the work proposed here analyzes the most significant impacts that DG has on the protection devices and proposes an adjustment method for the OCRs based on linear programming (LP) techniques with the aim of improving their response time to the different faults that may occur in the main feeder of the network. The distribution system selected for the study is the IEEE 34 bus system using DIgSILENT 14.1 software for its modeling and Matlab for the adjustment of the overcurrent devices. Results indicate that better coordination between protection devices are achieved if LP is used.
This article analyzes the current status of the lighting quality at the Escuela Técnica Superior de Ingeniería Aeronáutica y del Espacio (ETSIAE), the aerospace engineering faculty at the Universidad Politécnica de Madrid (UPM), and evaluates possible improvement actions based on the use of DIALux® lighting simulation software together with measured data. The results show rather low levels of measured illuminance on classroom desks and blackboards in one of the buildings comprising the faculty. The improvements proposed (a new coat of paint on the walls and replacement of luminaires) were simulated in four individual classrooms representing all rooms in two of the ETSIAE buildings (where the lower illuminance levels were measured). In order to study these improvements, the current situation of the four selected classrooms was simulated using DIALux® and fine-tuning attenuation of the luminaires to take into account their wear and tear. The correlation between the DIALux® simulation and the test results was analyzed with quite good results. The results clearly reveal a need to fully replace the classroom lighting systems in ETSIAE building A (the oldest building, dating back to 1955). According to the results from the selected classrooms, the average lighting over the desks can be greatly improved by using LED technology in order to meet UNE 12464-1 standard (that is, 500 lx, from an initial situation with much lower illuminance values: 129 lx to 295 lx). This article represents an innovative way to perform lighting improvement projects as real measured lighting data is used as initial input for the lighting simulations.
The recent increase in the use of renewable sources in electrical systems has transformed the electrical distribution network with the subsequent implementation of the distributed generation (DG) concept. The high penetration level of photovoltaic units increases their injected fault current that may result in a lack of coordination of fuse reclosers in distribution networks. One of the main protection devices that is generally used in rural distribution networks is the fuse. A correct size selection is key for ensuring good operation and coordination with other protection devices. The DG implementation makes the selection above more difficult, as the current flow both in steady state and in case of short-circuit is subject to alterations. A new protection fuse selection method for distribution networks with implemented DG is proposed in this paper with the aim of ensuring an effective coordination between them, avoiding untimely behaviors. Different case studies have been analyzed (for diverse locations of DG in the network with various penetration levels which represent 25%, 50%, 75%, and 100% of the total installed load), using an IEEE 13-node test feeder. Besides, a new model to analyze fuse performance is proposed in this work. This model has proven to fit the manufacturer’s data well, with a maximum error of 2% within the normal trip current values.