Ruth Diez-Ahedo

Ruth Diez-Ahedo

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2022 in Heliyon
Verified
Journal Article
Open access
AMAne Rivas Macho
Ane Rivas Macho
UEUnai Eletxigerra
Unai Eletxigerra
RDRuth Diez-Ahedo
Ruth Diez-Ahedo
SMSantos Merino
Santos Merino
ASAntton Sanjuan
Antton Sanjuan
Garbiñe OlabarríaGarbiñe Olabarría
Garbiñe Olabarría
The aim of this work is the design and 3D printing of a new electrochemical sensor for the detection of Listeria monocytogenes based on loop mediated isothermal amplification (LAMP). The food related diseases involve a serious health issue all over the world. Listeria monocytogenes is one of the major problems of contaminated food, this pathogen causes a disease called listeriosis with a high rate of hospitalization and mortality. Having a fast, sensitive and specific detection method for food quality control is a must in the food industry to avoid the presence of this pathogen in the food chain (raw materials, facilities and products). A point-of-care biosensor based in LAMP and electrochemical detection is one of the best options to detect the bacteria on site and in a very short period of time. With the numerical analysis of different geometries and flow rates during sample injection in order to avoid bubbles, an optimized design of the microfluidic biosensor chamber was selected for 3D-printing and experimental analysis. For the electrochemical detection, a novel custom gold concentric-3-electrode consisting in a working electrode, reference electrode and a counter electrode was designed and placed in the bottom of the chamber. The LAMP reaction was optimized specifically for a primers set with a limit of detection of 1.25 pg of genomic DNA per reaction and 100% specific for detecting all 12 Listeria monocytogenes serotypes and no other Listeria species or food-related bacteria. The methylene blue redox-active molecule was tested as the electrochemical transducer and shown to be compatible with the LAMP reaction and very clearly distinguished negative from positive food samples when the reaction is measured at the end-point inside the biosensor.

22 April 2020 in Polymers
Verified
Journal Article
Open access
PDF file
RDRuth Diez-Ahedo
Ruth Diez-Ahedo
XMXabier Mendibil
Xabier Mendibil
MMMari Carmen Márquez-Posadas
Mari Carmen Márquez-Posadas
IQIban Quintana
Iban Quintana
FGFrancisco González
Francisco González
SMSantos Merino
Santos Merino
Peripheral nerves are basic communication structures guiding motor and sensory information from the central nervous system to receptor units. Severed peripheral nerve injuries represent a large clinical problem with relevant challenges to successful synthetic nerve repair scaffolds as substitutes to autologous nerve grafting. Numerous studies reported the use of hollow tubes made of synthetic polymers sutured between severed nerve stumps to promote nerve regeneration while providing protection for external factors, such as scar tissue formation and inflammation. Few approaches have described the potential use of a lumen structure comprised of microchannels or microfibers to provide axon growth avoiding misdirection and fostering proper healing. Here, we report the use of a 3D porous microchannel-based structure made of a photocurable methacrylated polycaprolactone, whose mechanical properties are comparable to native nerves. The neuro-regenerative properties of the polymer were assessed in vitro, prior to the implantation of the 3D porous structure, in a 6-mm rat sciatic nerve gap injury. The manufactured implants were biocompatible and able to be resorbed by the host’s body at a suitable rate, allowing the complete healing of the nerve. The innovative design of the highly porous structure with the axon guiding microchannels, along with the observation of myelinated axons and Schwann cells in the in vivo tests, led to a significant progress towards the standardized use of synthetic 3D multichannel-based structures in peripheral nerve surgery.

11 October 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
AMAne Rivas Macho
Ane Rivas Macho
UEUnai Eletxigerra
Unai Eletxigerra
RDRuth Diez-Ahedo
Ruth Diez-Ahedo
ABAngela Barros
Angela Barros
SMSantos Merino
Santos Merino
Garbiñe OlabarríaGarbiñe Olabarría
Garbiñe Olabarría
The pandemic caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) caused more than 6 million deaths all over the world, demonstrating the need for a simple, fast and cost-effective point-of-care (POC) test for the detection of the virus. In this work, we developed an electrochemical sensor for SARS-CoV-2 virus detection on clinical samples based on loop-mediated isothermal amplification (LAMP). With the development of this novel sensor, the time of each measurement is significantly reduced by avoiding the DNA extraction step and replacing it with inactivation of the sample by heating it at 95 °C for 10 min. To make the reaction compatible with the sample pre-treatment, an RNase inhibitor was added directly to the premix. The LAMP product was measured in a novel, easy-to-use manufactured sensor containing a custom-made screen-printed carbon electrode. Electrochemical detection was performed with a portable potentiostat, and methylene blue was used as the redox-transducing molecule. The developed sensor achieved a limit of detection of 62 viral copies and was 100% specific for the detection of the SARS-CoV-2 virus. The performance of the electrochemical sensor was validated with nasopharyngeal samples, obtaining a sensibility and specificity of 100% compared to the gold standard RT-PCR method.

5 May 2021 in Surface Topography: Metrology and Properties
Verified
Journal Article
Closed access
NLNikolaos Lempesis
Nikolaos Lempesis
RKRudolf J Koopmans
Rudolf J Koopmans
RDRuth Diez-Ahedo
Ruth Diez-Ahedo
Per Magnus KristiansenPer Magnus Kristiansen
Per Magnus Kristiansen
Predicting wettability accurately across various materials, surface topographies and wetting liquids is undeniably of paramount importance as it sets the foundations for technological developments related to improved life quality, energy saving and economization of resources, thereby reducing the environmental impact for recycling and reuse. In this work, we extend and validate our recently published wetting model, constituting a refinement of the original Cassie-Baxter model after consideration of realistic curved liquid-air interfaces. Our model enabled more meaningful contact angle predictions, while it captured the experimentally observed trends between contact angle and surface roughness. Here, the formalism of our wetting model is further extended to 3D surface topographies, whereas the validity of our model, in its entirety, is evaluated. To this end, a total of thirty-two experimentally engineered surfaces of various materials exhibiting single- and multilevel hierarchical topographies of increasing complexity were utilized. Our model predictions were consistently in remarkable agreement with experimental data (deviations of 3%–6%) and, in most cases, within statistical inaccuracies of the experimental measurements. Direct comparison between experiments and modeling results corroborated that surface topographies featuring re-entrant geometries promoted enhanced liquid-repellency, whereas hierarchical multilevel surface topographies enabled even more pronounced nonwetting behaviors. For the sinusoidal topography, consideration of a second superimposing topography level almost doubled the observed water contact angles, whereas addition of a third level brought about an extra 12.5% increase in water contact angle.

1 January 2020 in Procedia CIRP
Verified
Journal Article
Open access
JMJ. Molinuevo
J. Molinuevo
IQI. Quintana
I. Quintana
ERE. Rodríguez-Vidal
E. Rodríguez-Vidal
RDRuth Diez-Ahedo
Ruth Diez-Ahedo
ARAritz Retolaza
Aritz Retolaza
CMC. Molpeceres
C. Molpeceres