Karsten Backhaus

Dr. Karsten Backhaus

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
TGThomas Götz
Thomas Götz
HKHannah Kirchner
Hannah Kirchner
Karsten BackhausKarsten Backhaus
Karsten Backhaus
High reliability, independence from environmental conditions, and the compact design of gas-insulated systems will lead to a wide application in future high voltage direct current (HVDC) transmission systems. Reliable operation of these assets can be ensured by applying meaningful and robust partial discharge diagnosis during development tests, acceptance tests, or operation. Therefore, the discharge behavior must be well understood. This paper aims to contribute to this understanding by investigating the partial discharge behavior of a distorted weakly inhomogeneous electrode arrangement in sulfur hexafluoride (SF6) and synthetic air under high DC voltage stress. In order to get a better understanding, the partial discharge current is measured under the variation of the insulation gas pressure, the gas type, the electric field strength, and the voltage polarity. Derived from this, a classification of the different discharge types is performed. As a result, four different discharge types can be categorized depending on the experimental parameters: discharge impulses, discharge impulses with superimposed pulseless discharges, discharge impulses with superimposed pulseless discharges, and subsequent smaller discharges and pulseless discharges. Concluding suggestions for partial discharge measurements under DC voltage stress are given: recommendations for the necessary measurement time, the applied voltage and polarity, and useful measurement techniques.

5 August 2020 in IEEE Access
Verified
Journal Article
Open access
KHKhaled Helal
Khaled Helal
RERamadan Aly Abd El-Aal
Ramadan Aly Abd El-Aal
Karsten BackhausKarsten Backhaus
Karsten Backhaus
The oil-paper insulation system is widely used for the insulation purposes of power transformers as a result of its ability to withstand high thermal and electrical stresses. The presence of a gas cavity between impregnated papers layer is a serious problem. When localized breakdown takes place within this cavity, partial discharge (PD) occurs and ages the rest of the insulation system. This aging phenomenon declines the expected life time of the insulation system and subsequently the life time of the power transformers. Dissolved gas analysis is a recommended technique that is used in order to assess the state of the insulation system inside the transformers. In this paper, PD is recorded in the case of gas cavity presence between the layers of the impregnated papers under the effect of AC and DC voltage stress. This record is extended from the instance of PD inception until the breakdown of the whole insulation system. Furthermore, the concentration of the gases that dissolve in the insulating oil due to the aging of the impregnated paper is measured eight times during the record of the PD. Finally, the degradation of the insulating papers is studied optically through the use of a microscope at different stages of the aging test. Depending on PD measurements, dissolved gas analysis (DGA) results, and the optical study of the paper aging, the evolution of the aging of oil-paper insulation system as a result of internal PD is declared when AC and DC voltage stresses are applied. It is obtained that the aging evolutionary process totally differs with the alteration of the applied voltage.

28 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
TLThomas Linde
Thomas Linde
JLJun Ting Loh
Jun Ting Loh
SKStefan Kornhuber
Stefan Kornhuber
Karsten BackhausKarsten Backhaus
Karsten Backhaus
SSStephan Schlegel
Stephan Schlegel
SGSteffen Großmann
Steffen Großmann
The increasing number of power electronic devices in electrical grids may lead to harmonic distorted voltages, which are considered to be possible causes of component failures. In this study, the dielectric losses of epoxy polymer and functionally filled silicone rubber (f-SiR) samples are investigated under harmonic distorted voltages in terms of their dielectric losses and the consequent heat source density within the material. The results suggest that the epoxy polymer samples behave linearly to the electric field strength and therefore allow good predictability of the dielectric losses. The investigated f-SiR samples exhibit a nonlinear behaviour when an electric field threshold is exceeded. The subsequent direct loss measurements under harmonic distorted voltage reveal a sharp rise of the dielectric loss with increasing electrical field strength. This leads to a higher risk of excessive heat in the material when harmonics are present. In conclusion, the investigation highlights the difficulties of estimating dielectric losses in nonlinear dielectric materials when distorted voltages are present.

9 July 2020 in Water
Verified
Journal Article
Open access
PDF file
SSStefan Schönekerl
Stefan Schönekerl
AWAstrid Weigert
Astrid Weigert
SUStephan Uhlig
Stephan Uhlig
KWKatharina Wellner
Katharina Wellner
RPRichard Pörschke
Richard Pörschke
André LerchAndré Lerch
André Lerch
In this study, a lab-scale plant was designed to treat water in continuous flow condition using non-thermal plasma technology. The core was an electrode system with connected high-voltage (HV) pulse generator. Its potentials and limitations were investigated in different experimental series with regard to the high-voltage settings, additions of oxygen-based species, different volume flow rates, and various physical-chemical properties of the process water such as conductivity, pH value, and temperature. Indigo carmine, para-Chlorobenzoic acid, and phenol were chosen as reference substances. The best HV settings was found for the voltage amplitude Û = 30 kV, the pulse repetition rate f = 0.4–0.6 kHz, and the pulse duration tb = 500 ns with an energy yield for 50% degradation G50, which is of 41.8 g∙kWh−1 for indigo carmine, 0.32 g∙kWh−1 for para-Chlorobenzoic acid, and 1.04 g∙kWh−1 for phenol. By adding 1 × 10−3 mol∙L−1 of oxygen, a 50% increase in degradation was achieved for para-Chlorobenzoic acid. Conductivity is the key parameter for degradation efficiency with a negative exponential dependence. The most important species for degradation are hydroxyl radicals (c ≈ 1.4 × 10−8 mol∙L−1) and solvated electrons (c ≈ 1.4 × 10−8 mol∙L−1). The results show that the technology could be upgraded from the small-scale experiments described in the literature to a pilot plant level and has the potential to be used on a large scale for different applications.

1 September 2014
Verified
Conference Paper
Closed access
Karsten BackhausKarsten Backhaus
Karsten Backhaus
JSJ. Speck
J. Speck
MHM. Hering
M. Hering
SGS. Grossmann
S. Grossmann
RFR. Fritsche
R. Fritsche
The paper presents two nonlinear dielectric effects from literature in mineral insulating oil, when stressed with DC voltage. In the first part it is shown how current time measurements fit Kerr field strength measurements. In the second part, the nonlinear current time effect is noted for polarity reversal. Both effects are caused by oil intrinsic charge carriers and their special dielectric properties. The current-time-behaviour and the nonlinear field strength distribution are calculated solving the Poisson-Nernst-Planck-equation time dependently.

1 July 2018
Verified
Conference Paper
Closed access
KHK. Helal
K. Helal
RER.A.Abd El-Aal
R.A.Abd El-Aal
SDS.S. Dessouky
S.S. Dessouky
Karsten BackhausKarsten Backhaus
Karsten Backhaus
JSJ. Speck
J. Speck
SGS. Grossmann
S. Grossmann
As a result of imperfect manufacturing process or ageing problems, a small gas cavity can be formed between the impregnated paper layers. Partial discharge (PD) activities take place when a localized breakdown occurs inside this embedded void. These PD activities degrade the healthy parts of the surrounding insulating papers and a complete breakdown can take place. Thus, it is important to define the main features of PD activities that occur as a result of a small void embedded between oil impregnated papers in order to distinguish such a defect under the operating conditions in the early stages before the whole insulation failure. In this research, a small disk void has been artificially embedded between oil impregnated paper layers. Phase resolved partial discharge pattern (PRPD), PD magnitude and PD repetition rate have been investigated in a voltage level 120% from the inception voltage limit. The degradation that takes place in the surrounding impregnated papers as a result of partial discharge activities has been also detected. The assessment of partial discharge characteristics and the consequent degradation process have been studied under the effect of AC and DC voltage stresses.