Undetected partial discharges (PDs) are a safety critical issue in high voltage (HV) gas-insulated systems (GIS). While the diagnosis of PDs under AC voltage is well-established, the analysis of PDs under DC voltage remains an active research field. A key focus of these investigations is the classification of different PD sources to enable subsequent sophisticated analysis. In this paper, we present an analysis of a 1D-CNN-based approach for classifying laboratory PD signals caused by metallic protrusions and conductive particles on the insulator of HVDC GIS, under both negative and positive potentials. Most notably, our study demonstrates that this type of neural network, regardless of the training order, can generalize learnings to operating voltage multiples that it has not previously encountered. We evaluate this generalization performance under the presence of additional white Gaussian noise and investigate the influence of excluding the amplitude-related information in the signal. Further, we compare the network's performance when using input signals in both the time and frequency domain.
The increasing number of power electronic devices in electrical grids may lead to harmonic distorted voltages, which are considered to be possible causes of component failures. In this study, the dielectric losses of epoxy polymer and functionally filled silicone rubber (f-SiR) samples are investigated under harmonic distorted voltages in terms of their dielectric losses and the consequent heat source density within the material. The results suggest that the epoxy polymer samples behave linearly to the electric field strength and therefore allow good predictability of the dielectric losses. The investigated f-SiR samples exhibit a nonlinear behaviour when an electric field threshold is exceeded. The subsequent direct loss measurements under harmonic distorted voltage reveal a sharp rise of the dielectric loss with increasing electrical field strength. This leads to a higher risk of excessive heat in the material when harmonics are present. In conclusion, the investigation highlights the difficulties of estimating dielectric losses in nonlinear dielectric materials when distorted voltages are present.
Joining by forming operations presents powerful and complex joining techniques. Clinching is a well-known joining process for use in sheet metalworking. Currently, clinched joints are focusing on mechanically enhanced connections. Additionally, the demand for integrating electrical requirements to transmit electrical currents will be increased in the future. This integration is particularly important, for instance, in the e-mobility sector. It enables connecting battery cells with electrical joints of aluminum and copper. Systematic use of the process-specific advantages of this joining method opens up the possibility to find and create electrically optimized connections. The optimization for the transmission of electrical currents will be demonstrated for clinched joints by adapting the tool geometry and the clinched joint design. Based on a comparison of the electrical joint resistance, the limit use temperature is defined for the joining materials used based on the microstructural condition and the aging condition due to artificial aging. As a result of the investigations carried out, reliable current transmission at a constant conductor temperature of up to 120 °C can be achieved for clinched copper–copper joints. In the case of pure aluminum joints and mixed joints of aluminum and copper, long-term stable current transmission can be ensured up to a conductor temperature of 100 °C.
The long-term behaviour of bolted joints used in high current systems is influenced by different ageing mechanisms. One of these mechanisms is the degradation of the joint force depending on temperature and time. If the joint force falls below a critical value, the joint resistance, the thermal dissipation and thereby the temperature of the joint can increase to a critical level. According to IEC 61439-1 the highest accepted temperature of joints is 140 °C. The influence of the force reduction to the ageing of joints is tested on current-carrying, bolted Cu-ETP (CW004A) busbar joints utilizing washers und spring washers at temperatures up to 160 °C. The joint force and the joint resistance are measured time-dependent. The possible physical mechanisms are discussed regarding to the results of the long-term tests and analyses of the busbar material by microscopic investigations. Based on this experimental data an extrapolation of the lifetime of such electrical joints is discussed in relation to the practical operating lifetime of more than 50 years.
Electrical heating rods are a commonly used application for switch point heating in order to keep switch points free from ice and snow. Clamps made of spring steel usually attach the heating rod to the rail. They are localized at certain positions at a distance from each other. Thermal images showed significant temperature differences on the surface of the heating rod depending on the longitudinal position. That might be an indicator of a varying heat transfer due to a changing joint force applied by the clamps. In order to investigate the correlation between the joint force and the heat transfer between the heating rod and rail, the clamping force of newly manufactured heating rod clamps was measured initially. Therefore, a modified tensile test was used. Applied thermal and mechanical loads over a period of 4000 h could reduce the clamping force by 13%. Finally, the correlation between the heat transfer resistance, the joint force and the surface condition was experimentally determined with a heating test setup. Considering only the clamp area, the specific thermal contact resistance will not change due to a change in the joint force. However, surface preconditioning, such as milling or an application of a thermal-conducting paste, is capable of significantly reducing the thermal contact resistance.
As a joining-by-forming process, clinching and the use of functional elements enable low-energy joining of components through form, force, and, under certain conditions, material closure. In addition to the transmission of mechanical forces, these joining processes can be qualified for additional electrical contact within the scope of functional integration for electro-mobile applications. For this purpose, maximizing the force and material closure is necessary to ensure a long-term, stable transmission of electrical currents. To this end, the electrical properties of the joints were optimized. The investigations carried out show the long-term behavior under normal operating conditions and the short-circuit case.