Xabier Amezua-Lasuen

Mr. Xabier Amezua-Lasuen

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2022 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
XAXabier Amezua-Lasuen
Xabier Amezua-Lasuen
MIMikel Iturrate
Mikel Iturrate
XGXabier Garikano
Xabier Garikano
ESENEKO SOLABERRIETA
ENEKO SOLABERRIETA

1 September 2023 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
XAXabier Amezua-Lasuen
Xabier Amezua-Lasuen
MIMikel Iturrate
Mikel Iturrate
XGXabier Garikano
Xabier Garikano
ESENEKO SOLABERRIETA
ENEKO SOLABERRIETA
Virtual facebow record techniques typically record the relationship of a maxillary digital scan to facial landmarks by aligning it to a 3-dimensional face scan. Three-dimensional face scans can be acquired with different facial scanning methods, but the impact of the facial scanning method on the accuracy (trueness and precision) of a virtual facebow record technique remains unclear. The purpose of this in vivo study was to assess the impact of the facial scanning method on the precision under the repeatability conditions (repeatability) of a virtual facebow record technique. Repeatability of the virtual facebow record technique with the following 3 clinical-grade facial scanning methods was determined and compared: a professional handheld scanner based on structured blue light scanning technology (PHS method); an attachment-type 3-dimensional sensor camera connected to a tablet and controlled with a mobile application (3DSC-T method); and a smartphone with an integrated 3-dimensional sensor camera controlled with a mobile application (3DSC-S method). To determine the repeatability of the virtual facebow record technique with each facial scanning method, 8 virtual facebow records of a completely dentate adult with class I occlusion and mesoprosopic facial form were obtained (8×3=24 in total); with these, 8 locations of a maxillary digital scan with respect to a common 3-dimensional face scan were obtained. Repeatability was determined in terms of deviations between located maxillary digital scans, determined, in turn, by calculating the distances between corresponding vertices for each of the possible nonrepeating combinations of pairs of located maxillary digital scans (8C2=28). Finally, the repeatability of the virtual facebow record technique with the different facial scanning methods was compared by using the Welch ANOVA test and the post hoc Games-Howell test (both α=.05). The repeatability of the virtual facebow record technique with PHS, 3DSC-T, and 3DSC-S facial scanning methods resulted in 0.243 ±0.094 mm, 0.437 ±0.171 mm, and 1.023 ±0.399 mm, respectively. Comparison of these results revealed that the facial scanning method had a statistically significant effect on the repeatability of the virtual facebow record technique (P<.001) and that its repeatability was statistically significantly greater with the PHS facial scanning method than with the 3DSC-T and 3DSC-S facial scanning methods and greater with the 3DSC-T facial scanning method than with the 3DSC-S facial scanning method (P<.001 for all pairwise comparisons). This study found that the facial scanning method had a great impact on the repeatability of the virtual facebow record technique and that the virtual facebow record technique was more repeatable with more accurate facial scanning methods.

1 September 2023 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
MJMikel Jauregi
Mikel Jauregi
XAXabier Amezua-Lasuen
Xabier Amezua-Lasuen
MIMikel Iturrate
Mikel Iturrate
ESENEKO SOLABERRIETA
ENEKO SOLABERRIETA
Although different digital occlusal analyzers have been marketed, comparative studies are lacking. The purpose of this in vitro study was to compare the repeatability and reproducibility of 2 different digital occlusal analyzers (T-Scan and OccluSense) for measuring the right- and left-side balance of occlusal contact forces. The repeatability and reproducibility of the 2 digital occlusal analyzers for measuring the balance of occlusal contact forces were determined and compared by using the Gauge Repeatability and Reproducibility tests based on the International Organization for Standardization (ISO), ISO 5725-2 and ISO 5725-3 standards. Ten different dental casts were mounted in the maximum intercuspation position on a semi-adjustable articulator. Then, the balance of occlusal contact forces in each of the 10 articulated dental casts was measured 24 times with each of the 2 digital occlusal analyzers. In addition, as the OccluSense, unlike the T-Scan, does not have a centering support for the piezoelectric film sensor, measurements with it were performed without and with a custom-designed and manufactured centering support. Finally, the repeatability and reproducibility of both digital occlusal analyzers were determined and compared using the Gauge Repeatability and Reproducibility tests. The repeatability and reproducibility tests revealed that only 0.8% of the variance of the measurements obtained with the T-Scan was due to repeatability and reproducibility (0.4% repeatability, 0.4% reproducibility). In contrast, 12% of the variance of the measurements obtained with the OccluSense was due to repeatability and reproducibility (2.2% repeatability, 9.8% reproducibility). However, when using OccluSense with the centering support, the variance decreased to 6.4% (2.8% repeatability, 3.6% reproducibility). According to the Automotive Industry Action Group classification, the repeatability and reproducibility of the T-Scan were good, those of the OccluSense poor, and those of the OccluSense with the centering support medium. The repeatability and reproducibility of the T-Scan were significantly better than those of the OccluSense for measuring the balance of occlusal contact forces. Furthermore, the repeatability and reproducibility of the OccluSense were significantly improved when used with a device to center the piezoelectric film sensor between the incisors. Nevertheless, the repeatability and reproducibility of the T-Scan were better.

15 September 2022 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
XGXabier Garikano
Xabier Garikano
XAXabier Amezua-Lasuen
Xabier Amezua-Lasuen
MIMikel Iturrate
Mikel Iturrate
ESENEKO SOLABERRIETA
ENEKO SOLABERRIETA
The alignment of the maxillary and mandibular digital scans obtained with an intraoral scanner (IOS) generates digital interocclusal records. Although the accuracy of maxillary and mandibular digital scans obtained from an IOS is widely studied, the accuracy of digital interocclusal records obtained with them is not; even less studied is the accuracy (trueness and precision) of the alignment methods that are available to obtain them. The purpose of this in vitro study was to assess the precision under repeatability conditions (repeatability) of the different alignment methods used to obtain digital interocclusal records. Digital scans of maxillary and mandibular casts of a dentate healthy adult were acquired with an IOS. Casts were then mounted in maximum intercuspal position in a semi-adjustable mechanical articulator (1801 AR Model PSH Articulator), and left and right occlusal digital scans were acquired with the IOS. Occlusal digital scans were repeated 7 times under repeatability conditions. After obtaining each pair of occlusal digital scans, the software program of the IOS automatically aligned the maxillary and mandibular digital scans with occlusal digital scans (TRI method), resulting in 7 digital interocclusal records composed of aligned maxillary and mandibular digital scans and occlusal digital scans. All 7 sets of aligned digital scans were exported and realigned in a dental computer-aided design software program by means of global and reference alignment methods (EXO-B and EXO-R methods, respectively). To assess the repeatability, the 7 aligned digital scan sets of each group were repositioned in the common coordinate system by aligning maxillary digital scans, and repeatability was calculated in terms of the distance between the vertices of the mandibular digital scans for each of the possible nonrepeating combinations of pairs (7C2=21). The repeatability was tested by using the Kruskal-Wallis test for nonparametric distribution followed by the Mann-Whitney U test and Bonferroni correction for pairwise comparisons (α=.05). The median with interquartile range for the TRI alignment method was 47 (27) μm for the EXO-B method 41 (25) μm and 16 (5) μm for EXO-R. The Kruskal-Wallis test showed statistical difference between test groups (P<.05). The post hoc Dunn test with Bonferroni adjustment detected significant statistical differences between the EXO-R-TRI (P<.001) and EXO-R-EXO-B (P<.001) alignment methods. This study found that the alignment method could influence the repeatability of digital interocclusal records. The reference best-fit alignment method (EXO-R) provided better repeatability.

15 June 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AAAmaia Amesti-Garaizabal
Amaia Amesti-Garaizabal
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
MSMª Fernanda Sola-Ruiz
Mª Fernanda Sola-Ruiz
LFLucia Fernandez-Estevan
Lucia Fernandez-Estevan
XAXabier Amezua-Lasuen
Xabier Amezua-Lasuen
JPJorge Alonso Pérez-Barquero
Jorge Alonso Pérez-Barquero
Background: The objective of this study was to digitally evaluate the effect of the cervical emergence of restorations in terms of gingival tissue volume. Materials and methods: In this study, 31 upper front teeth (from canine to canine) were selected and prepared using the biologically oriented preparation technique (BOPT). Each tooth had undergone a change in its provisional process with different emergence profile angles: 30° and 60°. Each sample was digitalised (STL file) using an intraoral scanner. By using various pieces of manipulation software for STL files, a volumetric analysis protocol was carried out. Changes in gingival thickness and position were measured at the buccal and the lingual positions. Results: By increasing the angulation of the emergence profile to 60°, the gingival thickness increased by 0.255 ± 0.381 mm (p = 0.001; t-test) at buccal and by 0.038 ± 0.381 mm at lingual (p = 0.600; t-test). In relation to the gingival height, at buccal, there is an apical displacement of 0.262 ± 0.246 mm (p = 0.001; t-test), and at lingual, there is an apical displacement of 0.390 ± 0.279 mm (p = 0.001; t-test). It was shown that an increase in the provisional emergence profile angle significantly diminishes the gingival height while significantly increasing gingival thickness. The Pearson’s correlation coefficient, r = 0.636, was moderately high and significant (p = 0.001; Pearson). Conclusions: The soft tissue surrounding the BOPT restored tooth evolved according to the prosthetic emergence angle of the provisional restoration, enabling us to plan for an apico-coronal and bucco-lingual displacement of the gingival tissue prior to the definitive restoration.

31 October 2022 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
XAXabier Amezua-Lasuen
Xabier Amezua-Lasuen
Gaizka ErkiziaGaizka Erkizia
Gaizka Erkizia
MJMikel Jauregi
Mikel Jauregi
ESENEKO SOLABERRIETA
ENEKO SOLABERRIETA
A technique for creating 3-dimensional virtual patients (3DVPs) by superimposing intraoral and facial digital scans guided with a novel aligner system is described. This aligner system supports design modifications to adapt to different facial scanning methods (FSMs) and reduce the impact of FSMs on the accuracy of 3DVPs. Two different designs of the aligner system are described: one for use with less-accurate FSMs and another for use with more-accurate FSMs. These virtual designs are available for download and use.