Piotr Koper

Dr. Piotr Koper

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Tunnelling and Underground Space Technology
Verified
Journal Article
Closed access
Małgorzata KrólMałgorzata Król
Małgorzata Król
Aleksander KrólAleksander Król
Aleksander Król
PKPiotr Koper
Piotr Koper
PWPaweł Wrona
Paweł Wrona

10 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
Joanna Ferdyn-GrygierekJoanna Ferdyn-Grygierek
Joanna Ferdyn-Grygierek
JKJan Kaczmarczyk
Jan Kaczmarczyk
MBMonika Blaszczok
Monika Blaszczok
PLPiotr Lubina
Piotr Lubina
PKPiotr Koper
Piotr Koper
ABAnna Bulińska
Anna Bulińska
Works of art are sensitive to environmental factors—mainly temperature and relative humidity—which, when stable, are generally recommended as ideal protection conditions, but in historical museum buildings, the required conditions are difficult to maintain, due to a lack of adequate heating, ventilation and air-conditioning systems. The paper presents the analysis of one-year measurements of temperature and relative humidity in three different museums in Poland. The aim of the research was to identify the risk to museum collections, due to unbalanced moisture loads and unstable indoor air temperatures, as well as to identify possible causes of fluctuations in these parameters. This article focuses on assessing the impact of variable external and internal loads on the hygrothermal parameters of indoor air. The profile of internal hygrothermal loads in exhibition halls varied over time, which resulted in a temporary variation of the indoor environmental parameters. The lack of appropriate systems, shaping the microclimate in the analyzed museums, and the lack of automatic control in existing devices did not allow to maintain the temperature and relative humidity within appropriate limits. In the museums, the maximum indoor temperature values were higher than those recommended in the requirements. Relative humidity values in all museums exceeded the recommended range both above and below.

25 November 2013 in Mokslas - Lietuvos ateitis
Verified
Journal Article
Open access
PDF file
ASAgnieszka Stobiecka
Agnieszka Stobiecka
BLBarbara Lipska
Barbara Lipska
PKPiotr Koper
Piotr Koper
The paper presents the requirements and functions of ventilation in ice rink arenas and discusses difficulties and problems of ventilation in such objects. Particular attention has been paid to two types of inside used air distribution systems – traditional-integrated and modern-separated where the functions of tribune ventilation and dehumidification of the air over the ice surface were separated. The flow of humid air and heat in the designed hall was modelled numerically using the ANSYS CFX code based on computational fluid dynamics (CFD) technique. Air distribution systems in the ice rink arena were compared based on the results of numerical calculations.

Wojciech KieratWojciech Kierat
Wojciech Kierat
WAWeronika Augustyn
Weronika Augustyn
PKPiotr Koper
Piotr Koper
MPMiroslawa Pawlyta
Miroslawa Pawlyta
ACArkadiusz Chruściel
Arkadiusz Chruściel
BWBernard Wyrwol
Bernard Wyrwol
In addition to looking for effective drugs and a vaccine, which are necessary to save and protect human health, it is also important to limit, or at least to slow, the spread of coronavirus. One important element in this action is the use of individual protective devices such as filtering facepiece masks. Currently, masks that use a mechanical filter, such as a HEPA (High Efficiency Particulate Air) filter, are often used. In some countries that do not have a well-developed healthcare system or in exceptional situations, there is a real and pressing need to restore filters for reuse. This article presents technical details for a very simple device for sterilization, including of HEPA polymer filters. The results of biological and microscopic tests confirming the effectiveness of the sterilization performed in the device are presented. The compact and portable design of the device also allows its use to disinfect other small surfaces, for example a small fragment of a floor, table, or bed.

20 March 2024 in Tunnelling and Underground Space Technology
Verified
Journal Article
Closed access
Aleksander KrólAleksander Król
Aleksander Król
KSKrystian Szewczyński
Krystian Szewczyński
Małgorzata KrólMałgorzata Król
Małgorzata Król
PKPiotr Koper
Piotr Koper
JBJakub Bielawski
Jakub Bielawski
WWWojciech Węgrzyński
Wojciech Węgrzyński

1 February 2014 in Energy and Buildings
Verified
Journal Article
Closed access
AŚAgata Świerc
Agata Świerc
SŚStanisław Świerc
Stanisław Świerc
HFHenryk Foit
Henryk Foit
PKPiotr Koper
Piotr Koper