Yin Wang

Dr. Yin Wang

College of Mechanical Engineering and Automation, Huaqiao University, Xiamen 361021, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2021 in Photonics
Verified
Journal Article
Open access
PDF file
QYQing YU
Qing YU
YZYali Zhang
Yali Zhang
WSWenjian Shang
Wenjian Shang
SDShengchao Dong
Shengchao Dong
CWChong Wang
Chong Wang
FCFang Cheng
Fang Cheng
Chromatic confocal microscopy is a widely used method to measure the thickness of transparent specimens. In conventional configurations, both the illumination and imaging axes are perpendicular to the test specimen. The reflection will be very weak when measuring high-transparency specimens. In order to overcome this limitation, a special chromatic confocal measuring system was developed based on inclined illumination. This design was able to significantly improve the signal-to-noise ratio. Compared with conventional designs, the proposed system was also featured by its biaxial optical scheme, instead of a coaxial one. This biaxial design improved the flexibility of the system and also increased the energy efficiency by avoiding light beam splitting. Based on this design, a prototype was built by the authors’ team. In this paper, the theoretical model of this specially designed chromatic confocal system is analyzed, and the calculating formula for the thickness of transparent specimen is provided accordingly. In order to verify its measurement performance, two experimental methodology and results are presented. The experimental results show that the repeatability is better than 0.54 μm, and the axial measurement accuracy of the system could reach the micron level.

5 March 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
CYCheng Yang
Cheng Yang
Yin WangYin Wang
Yin Wang
WFWei Fan
Wei Fan
In order to develop a high-resolution piezoelectric walking actuator with a long stroke for the wafer probe station, this work presents a design of a piezoelectric walking actuator with two auxiliary clamping feet elastically attached to major clamping feet. Its construction was introduced and its operating principle was analyzed. Structure design details were discussed and a prototype was proposed. The prototype was fabricated and tested. The experimental results show that the proposed actuator can operate stably along a 20 mm guider. The proposed design is suitable for precision motion control applications.

4 March 2022 in Photonics
Verified
Journal Article
Open access
PDF file
QYQing YU
Qing YU
CWChong Wang
Chong Wang
YZYali Zhang
Yali Zhang
SHShengming Hu
Shengming Hu
TLTing Liu
Ting Liu
LXLin Xi
Lin Xi
As a fast, high-accuracy and non-contact method, chromatic confocal microscopy is widely used in micro dimensional measurement. In this area, thickness measurement for transparent specimen is one of the typical applications. In conventional coaxial illumination mode, both the illumination and imaging axes are perpendicular to the test specimen. At the same time, there are also geometric measurement limitations in conventional mode. When measuring high-transparency specimen, the energy efficiency will be quite low, and the reflection will be very weak. This limitation will significantly affect the signal-to-noise ratio. The inclined illumination mode is a good solution to overcome this bottleneck, but the thickness results may vary at different axial positions of the sample. In this paper, an error correction method for thickness measurement of transparent samples is proposed. In the authors’ work, the error correction model was analyzed and simulated, and the influence caused by the different axial positions of sample could be theoretically eliminated. The experimental results showed that the thickness measurement of the samples was practically usable, and the measurement errors were significantly reduced by less than 2.12%, as compared to the uncorrected system. With this error correction model, the standard deviation had decreased significantly, and the axial measurement accuracy of the system can reach the micron level. Additionally, this model has the same correction effect on the samples with different refractive indexes. Therefore, the system can realize the requirement of measurement at different axial positions.

30 September 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
MSMengxin Sun
Mengxin Sun
FYFeng Yong
Feng Yong
Yin WangYin Wang
Yin Wang
Weiqing HuangWeiqing Huang
Weiqing Huang
SSSongfei Su
Songfei Su
Piezoelectric actuators are widely used in the optical field due to their high precision, compact structure, flexible design, and fast response. This paper presents a novel piezoelectric actuator with a bridge-type mechanism, which can be used to stabilize the images of an infrared imaging system. The bridge amplification mechanism is used to amplify the actuation displacement, and its structural parameters are optimized by the response surface method. The control strategy of the image stabilization system is formulated, and the overall structure of the infrared image stabilization system is designed according to the principle of image stabilization and the control strategy. The prototype was fabricated and verified by a series of experiments. In the test, the laminated piezoelectric ceramics are used as the driving element, and its maximum output displacement was about 17 μm under a voltage of 100 V. Firstly, the performance of the piezoelectric amplification mechanism was tested, and the maximum displacement of the piezoelectric micro-motion mechanism was 115 μm. The displacement amplification ratio of the mechanism was 5.7. Then, the step distance and response time of the micro-displacement mechanism were measured by inputting the stepping signal. When the input voltage increased to 3 V, 5 V, and 7 V, the stepping displacements of the mechanism were 2.4 μm, 4.1 μm, and 5.8 μm. Finally, the image stabilization effect of the designed mechanism was verified by imaging timing control and feedback signal processing.

13 August 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
JLJiayin Li
Jiayin Li
Yin WangYin Wang
Yin Wang
ZCZiyan Chen
Ziyan Chen
FCFang Cheng
Fang Cheng
QYQing YU
Qing YU
A minimized linear ultrasonic motor was proposed, and two flexural bimorph vibrators were utilized to form its stator. The construction of the linear ultrasonic motor and its operation principle was introduced. Two working modes with the same local deformation distribution were chosen on the basis of Finite Element Analysis (FEA). To obtain its optimized structural parameters, sensitivities on frequency difference were calculated, and a way of decreasing the frequency difference of two working modes was introduced. A prototype of the optimized model was made. The modal testing of the stator and its performance evaluation was conducted. The modal testing results were in good agreement with that of the simulation. The maximum speed of the prototype is 245 mm/s, and its maximum thrust is 1.6 N.

24 February 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FCFang Cheng
Fang Cheng
JZJingwu Zou
Jingwu Zou
HSHang Su
Hang Su
Yin WangYin Wang
Yin Wang
QYQing YU
Qing YU
In this paper, a novel design of a surface topography measurement system is proposed, to address the challenge of accurate measurement in a relatively large area. This system was able to achieve nanometer-scale accuracy in a measurement range of 100 mm × 100 mm. The high accuracy in a relatively large area was achieved by implementing two concepts: (1) A static coordinate system was configured to minimize the Abbe errors. (2) A differential measurement configuration was developed by setting up a confocal sensor and a film interferometry module to separate the motion error. In order to accommodate the differential measurement probes from both sides of the central stage and ensure the system rigidity with balanced supports, separate linear guides were introduced in this system. Therefore, the motion Degree of Freedom (DoF) was analyzed in order to address the challenge of an over-constrained mechanism due to multiple kinematic pairs. An optimal configuration and a quick assembly process were proposed accordingly. The experimental results presented in this paper showed that the proposed modular measurement system was able to achieve 10 nm accuracy in measuring the surface roughness and 100 nm accuracy in measuring the step height in the range of 100 mm × 100 mm. In summary, the novel concept of this study is the build of a high-accuracy system with conventional mechanical components.