This paper presents a braking strategy analysis for a Formula SAE electric race car. The proposed braking strategy aims to increase the recovery energy by a relevant distribution of the braking forces between the rear and front wheels. A mathematical model of the car is presented, and a simulation is performed in Matlab-Simulink. The model is organized using the energetic macroscopic representation graphical formalism. A real racetrack driving cycle is considered. Three braking strategies are compared considering the energy recovery and the vehicle stability. The simulation results show that the proposed strategy enables higher energy recovery while avoiding locking on both rear and front wheels. As in such a race the driving range is fixed, the reduction in energy consumption can be used to reduce the battery size. The battery weight can thus be decreased to improve the vehicle performance during competition.
The integration of renewable energy sources, battery energy storage, and electric vehicles into industrial systems unlocks new opportunities for reducing emissions and improving sustainability. However, the coordination and management of these new technologies also pose new challenges due to complex interactions. This paper proposes a methodology for designing a holistic energy management system, based on advanced digital twins and optimization techniques, to minimize the cost of supplying industry loads and electric vehicles using local renewable energy sources, second-life battery energy storage systems, and grid power. The digital twins represent and forecast the principal energy assets, providing variables necessary for optimizers, such as photovoltaic generation, the state of charge and state of health of electric vehicles and stationary batteries, and industry power demand. Furthermore, a two-layer optimization framework based on mixed-integer linear programming is proposed. The optimization aims to minimize the cost of purchased energy from the grid, local second-life battery operation, and electric vehicle fleet charging. The paper details the mathematical fundamentals behind digital twins and optimizers. Finally, a real-world case study is used to demonstrate the operation of the proposed approach within the context of the waste collection and management industry. The study confirms the effectiveness of digital twins for forecasting and performance analysis in complex energy systems. Furthermore, the optimization strategies reduce the operational costs by 1.3%, compared to the actual industry procedure, resulting in daily savings of EUR 24.2 through the efficient scheduling of electric vehicle fleet charging.
The increased penetration of power electronics interfaced resources in modern power systems is unlocking new opportunities and challenges. New concepts like multiport converters can further enhance the efficiency and power density of power electronics-based solutions. The triple active bridge is an isolated multiport converter with soft switching and high voltage gain that can integrate different sources, storage, and loads, or act as a building block for modular systems. However, the triple active bridge suffers from power flow cross-coupling, which affects its dynamic performance if it is not removed or mitigated. Unlike the extensive literature on two-port power converters, studies on modeling and control comparison for multiport converters are still lacking. Therefore, this paper presents and compares different modeling and decoupling control approaches applied to the triple active bridge converter, highlighting their benefits and limitations. The converter operation and modulation are introduced, and modeling and control strategies based on the single phase shift power flow control are detailed. The switching model, generalized full-order average model, and the reduced-order model derivations are presented thoroughly, and a comparison reveals that first harmonic approximations can be detrimental when modeling the triple active bridge. Furthermore, the model accuracy is highly sensitive to the operating point, showing that the generalized average model better represents some dynamics than the lossless reduced-order model. Furthermore, three decoupling control strategies are derived aiming to mitigate cross-coupling effects to ensure decoupled power flow and improve system stability. To assess their performance, the TAB converter is subjected to power and voltage disturbances and parameter uncertainty. A comprehensive comparison reveals that linear PI controllers with an inverse decoupling matrix can effectively control the TAB but exhibit large settling time and voltage deviations due to persistent cross-coupling. Furthermore, the decoupling matrix is highly sensitive to inaccuracies in the converter’s model parameters. In contrast, linear active disturbance rejection control and sliding mode control based on a linear extended state observer achieve rapid stabilization, demonstrating strong decoupling capability under disturbances. Furthermore, both control strategies demonstrate robust performance under parameter uncertainty.
1 November 2026 in IEEE Transactions on Power Electronics