Representative Publications

View All Publications
20 April 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Martina ZaltieriMartina Zaltieri
Martina Zaltieri
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Andrea NicolòAndrea Nicolò
Andrea Nicolò
Daniele TosiDaniele Tosi
Daniele Tosi
Emiliano SchenaEmiliano Schena
Emiliano Schena
Systems for cardiorespiratory monitoring hold tremendous promise for many applications in clinical settings, harsh environments, sports science and telemonitoring. However, the translation in the real world is challenging because it is difficult to develop unobtrusive and comfortable systems with high metrological performance. Recent advances in fiber optic technology in the field of sensing and their application to instrument wearable systems can tackle the main issues in this field. In this work, we focused on the recent advances in cardiorespiratory monitoring of fiber Bragg grating (FBGs) sensors which are one of the most popular sensors based on fiber optic technology. We provide an overview of the FBGs working principle and performance. We also describe the most popular and promising configurations based on FBGs used for cardiorespiratory monitoring.

18 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
ACArianna Carnevale
Arianna Carnevale
JDJessica D'Abbraccio
Jessica D'Abbraccio
LMLuca Massari
Luca Massari
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Emiliano SchenaEmiliano Schena
Emiliano Schena
Musculoskeletal disorders are the most common form of occupational ill-health. Neck pain is one of the most prevalent musculoskeletal disorders experienced by computer workers. Wrong postural habits and non-compliance of the workstation to ergonomics guidelines are the leading causes of neck pain. These factors may also alter respiratory functions. Health and safety interventions can reduce neck pain and, more generally, the symptoms of musculoskeletal disorders and reduce the consequent economic burden. In this work, a multi-parametric wearable system based on two fiber Bragg grating sensors is proposed for monitoring neck movements and breathing activity of computer workers. The sensing elements were positioned on the neck, in the frontal and sagittal planes, to monitor: (i) flexion-extension and axial rotation repetitions, and (ii) respiratory frequency. In this pilot study, five volunteers were enrolled and performed five repetitions of both flexion-extension and axial rotation, and ten breaths of both quite breathing and tachypnea. Results showed the good performances of the proposed system in monitoring the aforementioned parameters when compared to optical reference systems. The wearable system is able to well-match the trend in time of the neck movements (both flexion-extension and axial rotation) and to estimate mean and breath-by-breath respiratory frequency values with percentage errors ≤6.09% and ≤1.90%, during quiet breathing and tachypnea, respectively.

16 March 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Martina ZaltieriMartina Zaltieri
Martina Zaltieri
Riccardo SabbadiniRiccardo Sabbadini
Riccardo Sabbadini
ACArianna Carnevale
Arianna Carnevale
Domenico FormicaDomenico Formica
Domenico Formica
There is a growing demand of comfortable and unobtrusive wearable systems for monitoring a variety of physiological parameters and in particular the respiratory frequency (fR). The most popular techniques for fR monitoring cannot be used in several clinical applications and in unstructured environment. These issues have fostered a dramatic growth of interest for wearable systems devoted to monitor fR. In this arena, fiber Bragg grating (FBG) sensors have gained due to a variety of benefits. In this work, we designed and fabricated an FBG-based wearable device for fR monitoring from the nasal airflow. The proposed design does not require a mask to improve the comfortability and acceptability of the system. The sensing element was functionalized by a hygroscopic coating material to make the FBG sensitive to relative humidity changes. This feature allows calculating fR starting from the discrimination between the inspiration and expiration phases. A pilot study on 6 volunteers was designed to assess the system during three different breathing stages (i.e., slow, normal and fast breathing). Results showed high performance of the proposed wearable device in detecting mean and breath-by-breath fR values (i.e., mean percentage errors ≤ 2.29 % and bias ≤ 0.31 breaths per minute) during slow breathing, normal breathing, and fast breathing.

6 November 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JTJoshua Di Tocco
Joshua Di Tocco
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Martina ZaltieriMartina Zaltieri
Martina Zaltieri
GDGiacomo D'Alesio
Giacomo D'Alesio
MFMariangela Filosa
Mariangela Filosa
Emiliano SchenaEmiliano Schena
Emiliano Schena
Workers experiencing high levels of stress may suffer from poor motivation, low level of attention, and physical disorders which, in turn, may lead to work injuries. Respiratory frequency (f R ) is considered one of the most reliable indicators of the mental load and fatigue state of workers. Monitoring this parameter through wearable devices represents an efficient solution for the maintenance of Occupational Health and Safety. We developed an innovative wearable system equipped with flexible sensors based on fiber Bragg gratings (FBGs) to monitor f R in static and dynamic conditions characterizing occupational settings. This article provides a description of the system and of the metrological characteristics of the flexible sensors in terms of response to strain and temperature changes, and hysteresis error. The performances of the device, evaluated in a laboratory during the execution of tasks mimicking real work activity, are also reported. The obtained promising results encourage the engineering of the system for use in real workplaces to collect quantitative information on the psychophysical state of workers and its relation to stress level.

28 November 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Martina ZaltieriMartina Zaltieri
Martina Zaltieri
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
MBMarco Bravi
Marco Bravi
Michele Arturo CaponeroMichele Arturo Caponero
Michele Arturo Caponero
SSSilvia Sterzi
Silvia Sterzi
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Due to prolonged incorrect sitting posture, upper body musculoskeletal disorders (UBMDs) are largely widespread among sedentary workers. Monitoring employees' sitting behaviors could be of great help in minimizing UBMDs' occurrence. In addition, being primarily influenced by psycho-physical stress conditions, respiratory rate (RR) would be a further useful parameter to delineate the workers' state of health. Wearable systems have emerged as a viable option for sitting posture and RR monitoring since enable continuous data collecting with no posture disturbances. Nevertheless, the main limits are poor fit, cumbersomeness, and movement restriction resulting in discomfort for the user. In addition, only few wearable solutions can track both these parameters contextually. To address these problems, in this study a flexible wearable system composed of seven modular sensing elements based on fiber Bragg grating (FBG) technology and designed to be worn on the back has been proposed to recognize the most common sitting postures (i.e., kyphotic, upright and lordotic) and estimate RR. The assessment was performed on ten volunteers showing good performances in postures recognition via Naïve Bayes classificator (accuracy >96.9%) and agreement with the benchmark in RR estimation (MAPE ranging between 0.74% and 3.83%, MODs close to zero, and LOAs between 0.76 bpm and 3.63 bpm). The method was then successfully tested on three additional subjects under different breathing conditions. The wearable system could offer great support for a better understanding of the workers' posture attitudes and contribute to gathering RR information to depict an overall picture of the users' state of health.

19 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Martina ZaltieriMartina Zaltieri
Martina Zaltieri
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
FCFilippo Cauti
Filippo Cauti
Emiliano SchenaEmiliano Schena
Emiliano Schena
Cardiac radiofrequency ablation (RFA) has received substantial attention for the treatment of multiple arrhythmias. In this scenario, there is an ever-growing demand for monitoring the temperature trend inside the tissue as it may allow an accurate control of the treatment effects, with a consequent improvement of the clinical outcomes. There are many methods for monitoring temperature in tissues undergoing RFA, which can be divided into invasive and non-invasive. This paper aims to provide an overview of the currently available techniques for temperature detection in this clinical scenario. Firstly, we describe the heat generation during RFA, then we report the principle of work of the most popular thermometric techniques and their features. Finally, we introduce their main applications in the field of cardiac RFA to explore the applicability in clinical settings of each method.