Background: Rotator cuff retear (RCR) is one of the main postoperative drawbacks. RCR can be considered a multifactorial issue, which causes are related either to biological than biomechanical factors. The aim of this study was to define the incidence of RCR after surgical treatment at different time points and to identify the main factors influencing the postoperative rotator cuff (RC) healing.Methods: A systematic review and meta-analysis were performed following the PRISMA guidelines. A comprehensive search of the literature was carried out in July 2020, using PubMed and Cochrane Library databases. Only level 1 and 2 clinical evidence studies were included. Studies were included if patients with preoperative repairable full-thickness RC tears were treated surgically, and if studies reported postoperative RCR confirmed by imaging diagnostic. The association between timing of retear and follow-up time points were investigated using an inverse-variance method of pooling data. A subgroup meta-analysis was performed using the DerSimonian and Laird method for the estimation of the between-study variance, i.e., τ2. The association between retear rate after surgery and patients’ age, preoperative tear size, fatty infiltration, postoperative rehabilitation protocol, surgical techniques, and RC repairs was determined by expressing the effect measure in terms of odds ratio (OR) with 95% confidence interval (CI). The Mantel-Haenszel method with 95% CIs was used.Results: Thirty-one articles were included in this study. The percentage of RCR after surgery was 15% at 3 months follow-up, 21% at 3–6 months follow-up, 16% at 6–12 months follow-up, 21% at 12–24 months follow-up, 16% at follow-up longer than 24 months. The main factors influencing RC healing are both patient-related (i.e., age, larger tear size, fatty infiltration) and not patient-related (i.e., postoperative rehabilitation protocol, surgical techniques, and procedures).Conclusions: Postoperative RC healing is influenced by patient-related and non-patient-related factors. Further high-level clinical studies are needed to provide highly relevant clinical results.
Virtual reality (VR) systems are becoming increasingly attractive as joint kinematics monitoring systems during rehabilitation. This study aimed to evaluate the accuracy of the Oculus Quest 2 in measuring translational and rotational displacements. As the Oculus Quest 2 was chosen for future applications in shoulder rehabilitation, the translation range (minimum: ~200 mm, maximum: ~700 mm) corresponded to the forearm length of the 5th percentile female and the upper limb length of the 95th percentile male. The controller was moved on two structures designed to allow different translational displacements and rotations in the range 0–180°, to cover the range of motion of the upper limb. The controller measures were compared with those of a Qualisys optical capture system. The results showed a mean absolute error of 13.52 ± 6.57 mm at a distance of 500 mm from the head-mounted display along the x-direction. The maximum mean absolute error for rotational displacements was found to be 1.11 ± 0.37° for a rotation of 40° around the z-axis. Oculus Quest 2 is a promising VR tool for monitoring shoulder kinematics during rehabilitation. The inside-out movement tracking makes Oculus Quest 2 a viable alternative to traditional motion analysis systems.
Musculoskeletal disorders are the most common form of occupational ill-health. Neck pain is one of the most prevalent musculoskeletal disorders experienced by computer workers. Wrong postural habits and non-compliance of the workstation to ergonomics guidelines are the leading causes of neck pain. These factors may also alter respiratory functions. Health and safety interventions can reduce neck pain and, more generally, the symptoms of musculoskeletal disorders and reduce the consequent economic burden. In this work, a multi-parametric wearable system based on two fiber Bragg grating sensors is proposed for monitoring neck movements and breathing activity of computer workers. The sensing elements were positioned on the neck, in the frontal and sagittal planes, to monitor: (i) flexion-extension and axial rotation repetitions, and (ii) respiratory frequency. In this pilot study, five volunteers were enrolled and performed five repetitions of both flexion-extension and axial rotation, and ten breaths of both quite breathing and tachypnea. Results showed the good performances of the proposed system in monitoring the aforementioned parameters when compared to optical reference systems. The wearable system is able to well-match the trend in time of the neck movements (both flexion-extension and axial rotation) and to estimate mean and breath-by-breath respiratory frequency values with percentage errors ≤6.09% and ≤1.90%, during quiet breathing and tachypnea, respectively.
Background: This study intends to summarize the causes, clinical examination, and treatments of scapular dyskinesis (SD) and to briefly investigate whether alteration can be managed by a precision rehabilitation protocol planned on the basis of features derived from clinical tests. Methods: We performed a comprehensive search of PubMed, Cochrane, CINAHL and EMBASE databases using various combinations of the keywords “Rotator cuff”, “Scapula”, “Scapular Dyskinesis”, “Shoulder”, “Biomechanics” and “Arthroscopy”. Results: SD incidence is growing in patients with shoulder pathologies, even if it is not a specific injury or directly related to a particular injury. SD can be caused by multiple factors or can be the trigger of shoulder-degenerative pathologies. In both cases, SD results in a protracted scapula with the arm at rest or in motion. Conclusions: A clinical evaluation of altered shoulder kinematics is still complicated. Limitations in observing scapular motion are mainly related to the anatomical position and function of the scapula itself and the absence of a tool for quantitative SD clinical assessment. High-quality clinical trials are needed to establish whether there is a possible correlation between SD patterns and the specific findings of shoulder pathologies with altered scapular kinematics.
Unobtrusive and wearable devices are gaining large acceptance in the continuous monitoring of physiological parameters. Among the five vital signs, respiratory rate (fR) can be used to detect physiological abnormalities and health status changes. The purpose of this work was to investigate the performances of a multi-sensor smart garment in estimating the fR during walking and running activities. Bespoke algorithms have been implemented to retrieve fR values from raw data. Experiments were carried out on ten male volunteers during walking and running activities at selected speeds controlled by a treadmill (i.e., from 1.6 km.h-1 to 8.0 km.h-1). Data were analysed in both frequency and time domains. In the frequency domain, fR was analyzed considering a time window of 20 s. The 97% of fR estimated by the garment agreed with the reference (i.e., flowmeter) values in the range 13 breaths per minute (bpm). In the time domain, breath-by-breath fR analysis was carried out. The garment performance was evaluated in terms of mean absolute error (MAE), standard error (SE),mean percentage error (mean %E[i]) and by the Bland-Altman analysis. Good agreement with the reference device was testified by low MAE (<1.86 bpm), SE (<0.21 bpm), mean %E[i] (<2.83 ), and by the Bland-Altman analysis (Mean of Differences = 0.22 bpm, Limits of Agreement = 6.06 bpm). Summing up, the garment based on six sensing elements and related bespoke algorithms are able to provide robust information about fR on both average and breath-by-breath bases even during physical activities.
There is a growing demand of comfortable and unobtrusive wearable systems for monitoring a variety of physiological parameters and in particular the respiratory frequency (fR). The most popular techniques for fR monitoring cannot be used in several clinical applications and in unstructured environment. These issues have fostered a dramatic growth of interest for wearable systems devoted to monitor fR. In this arena, fiber Bragg grating (FBG) sensors have gained due to a variety of benefits. In this work, we designed and fabricated an FBG-based wearable device for fR monitoring from the nasal airflow. The proposed design does not require a mask to improve the comfortability and acceptability of the system. The sensing element was functionalized by a hygroscopic coating material to make the FBG sensitive to relative humidity changes. This feature allows calculating fR starting from the discrimination between the inspiration and expiration phases. A pilot study on 6 volunteers was designed to assess the system during three different breathing stages (i.e., slow, normal and fast breathing). Results showed high performance of the proposed wearable device in detecting mean and breath-by-breath fR values (i.e., mean percentage errors ≤ 2.29 % and bias ≤ 0.31 breaths per minute) during slow breathing, normal breathing, and fast breathing.