Riccardo Sabbadini

Mr. Riccardo Sabbadini

Università Campus Bio-Medico di Roma
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
ACArianna Carnevale
Arianna Carnevale
JDJessica D'Abbraccio
Jessica D'Abbraccio
LMLuca Massari
Luca Massari
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Emiliano SchenaEmiliano Schena
Emiliano Schena
Musculoskeletal disorders are the most common form of occupational ill-health. Neck pain is one of the most prevalent musculoskeletal disorders experienced by computer workers. Wrong postural habits and non-compliance of the workstation to ergonomics guidelines are the leading causes of neck pain. These factors may also alter respiratory functions. Health and safety interventions can reduce neck pain and, more generally, the symptoms of musculoskeletal disorders and reduce the consequent economic burden. In this work, a multi-parametric wearable system based on two fiber Bragg grating sensors is proposed for monitoring neck movements and breathing activity of computer workers. The sensing elements were positioned on the neck, in the frontal and sagittal planes, to monitor: (i) flexion-extension and axial rotation repetitions, and (ii) respiratory frequency. In this pilot study, five volunteers were enrolled and performed five repetitions of both flexion-extension and axial rotation, and ten breaths of both quite breathing and tachypnea. Results showed the good performances of the proposed system in monitoring the aforementioned parameters when compared to optical reference systems. The wearable system is able to well-match the trend in time of the neck movements (both flexion-extension and axial rotation) and to estimate mean and breath-by-breath respiratory frequency values with percentage errors ≤6.09% and ≤1.90%, during quiet breathing and tachypnea, respectively.

28 October 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
JTJoshua Di Tocco
Joshua Di Tocco
MBMarco Bravi
Marco Bravi
ACArianna Carnevale
Arianna Carnevale
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Emiliano SchenaEmiliano Schena
Emiliano Schena
Unobtrusive and wearable devices are gaining large acceptance in the continuous monitoring of physiological parameters. Among the five vital signs, respiratory rate (fR) can be used to detect physiological abnormalities and health status changes. The purpose of this work was to investigate the performances of a multi-sensor smart garment in estimating the fR during walking and running activities. Bespoke algorithms have been implemented to retrieve fR values from raw data. Experiments were carried out on ten male volunteers during walking and running activities at selected speeds controlled by a treadmill (i.e., from 1.6 km.h-1 to 8.0 km.h-1). Data were analysed in both frequency and time domains. In the frequency domain, fR was analyzed considering a time window of 20 s. The 97% of fR estimated by the garment agreed with the reference (i.e., flowmeter) values in the range 13 breaths per minute (bpm). In the time domain, breath-by-breath fR analysis was carried out. The garment performance was evaluated in terms of mean absolute error (MAE), standard error (SE),mean percentage error (mean %E[i]) and by the Bland-Altman analysis. Good agreement with the reference device was testified by low MAE (<1.86 bpm), SE (<0.21 bpm), mean %E[i] (<2.83 ), and by the Bland-Altman analysis (Mean of Differences = 0.22 bpm, Limits of Agreement = 6.06 bpm). Summing up, the garment based on six sensing elements and related bespoke algorithms are able to provide robust information about fR on both average and breath-by-breath bases even during physical activities.

16 March 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Martina ZaltieriMartina Zaltieri
Martina Zaltieri
Riccardo SabbadiniRiccardo Sabbadini
Riccardo Sabbadini
ACArianna Carnevale
Arianna Carnevale
Domenico FormicaDomenico Formica
Domenico Formica
There is a growing demand of comfortable and unobtrusive wearable systems for monitoring a variety of physiological parameters and in particular the respiratory frequency (fR). The most popular techniques for fR monitoring cannot be used in several clinical applications and in unstructured environment. These issues have fostered a dramatic growth of interest for wearable systems devoted to monitor fR. In this arena, fiber Bragg grating (FBG) sensors have gained due to a variety of benefits. In this work, we designed and fabricated an FBG-based wearable device for fR monitoring from the nasal airflow. The proposed design does not require a mask to improve the comfortability and acceptability of the system. The sensing element was functionalized by a hygroscopic coating material to make the FBG sensitive to relative humidity changes. This feature allows calculating fR starting from the discrimination between the inspiration and expiration phases. A pilot study on 6 volunteers was designed to assess the system during three different breathing stages (i.e., slow, normal and fast breathing). Results showed high performance of the proposed wearable device in detecting mean and breath-by-breath fR values (i.e., mean percentage errors ≤ 2.29 % and bias ≤ 0.31 breaths per minute) during slow breathing, normal breathing, and fast breathing.

25 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JTJoshua Di Tocco
Joshua Di Tocco
LRLuigi Raiano
Luigi Raiano
Riccardo SabbadiniRiccardo Sabbadini
Riccardo Sabbadini
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Domenico FormicaDomenico Formica
Domenico Formica
Emiliano SchenaEmiliano Schena
Emiliano Schena
The continuous and simultaneous monitoring of physiological parameters represents a key aspect in clinical environments, remote monitoring and occupational settings. In this regard, respiratory rate (RR) and heart rate (HR) are correlated with several physiological and pathological conditions of the patients/workers, and with environmental stressors. In this work, we present and validate a wearable device for the continuous monitoring of such parameters. The proposed system embeds four conductive sensors located on the user’s chest which allow retrieving the breathing activity through their deformation induced during cyclic expansion and contraction of the rib cage. For monitoring HR we used an embedded IMU located on the left side of the chest wall. We compared the proposed device in terms of estimating HR and RR against a reference system in three scenarios: sitting, standing and supine. The proposed system reliably estimated both RR and HR, showing low error averaged along subjects in all scenarios. This is the first study focused on the feasibility assessment of a wearable system based on a multi-sensor configuration (i.e., conductive sensors and IMU) for RR and HR monitoring. The promising results encourage the application of this approach in clinical and occupational settings.

9 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Martina ZaltieriMartina Zaltieri
Martina Zaltieri
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
MBMarco Bravi
Marco Bravi
Riccardo SabbadiniRiccardo Sabbadini
Riccardo Sabbadini
Emiliano SchenaEmiliano Schena
Emiliano Schena
Low back pain (LBP) is one of the musculoskeletal disorders that most affects workers. Among others, one of the working categories which mainly experiences such disease are video terminal workers. As it causes exploitation of the National Health Service and absenteeism in workplaces, LBP constitutes a relevant socio-economic burden. In such a scenario, a prompt detection of wrong seating postures can be useful to prevent the occurrence of this disorder. To date, many tools capable of monitoring the spinal range of motions (ROMs) are marketed, but most of them are unusable in working environments due to their bulkiness, discomfort and invasiveness. In the last decades, fiber optic sensors have made their mark allowing the creation of light and compact wearable systems. In this study, a novel wearable device embedding a Fiber Bragg Grating sensor for the detection of lumbar flexion-extensions (F/E) in seated subjects is proposed. At first, the manufacturing process of the sensing element was shown together with its mechanical characterization, that shows linear response to strain with a high correlation coefficient (R2 > 0.99) and a sensitivity value (Sε) of 0.20 nm∙mε−1. Then, the capability of the wearable device in measuring F/E in the sagittal body plane was experimentally assessed on a small population of volunteers, using a Motion Capture system (MoCap) as gold standard showing good ability of the system to match the lumbar F/E trend in time. Additionally, the lumbar ROMs were evaluated in terms of intervertebral lumbar distances (Δ d L 3 − L 1 ) and angles, exhibiting moderate to good agreement with the MoCap outputs (the maximum Mean Absolute Error obtained is ~16% in detecting Δ d L 3 − L 1 ). The proposed wearable device is the first attempt for the development of FBG-based wearable systems for workers’ safety monitoring.

6 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Emilio AndreozziEmilio Andreozzi
Emilio Andreozzi
Riccardo SabbadiniRiccardo Sabbadini
Riccardo Sabbadini
JCJessica Centracchio
Jessica Centracchio
Paolo BifulcoPaolo Bifulco
Paolo Bifulco
Andrea IraceAndrea Irace
Andrea Irace
Michele RiccioMichele Riccio
Michele Riccio
Pulse waves (PWs) are mechanical waves that propagate from the ventricles through the whole vascular system as brisk enlargements of the blood vessels’ lumens, caused by sudden increases in local blood pressure. Photoplethysmography (PPG) is one of the most widespread techniques employed for PW sensing due to its ability to measure blood oxygen saturation. Other sensors and techniques have been proposed to record PWs, and include applanation tonometers, piezoelectric sensors, force sensors of different kinds, and accelerometers. The performances of these sensors have been analyzed individually, and their results have been found not to be in good agreement (e.g., in terms of PW morphology and the physiological parameters extracted). Such a comparison has led to a deeper comprehension of their strengths and weaknesses, and ultimately, to the consideration that a multimodal approach accomplished via sensor fusion would lead to a more robust, reliable, and potentially more informative methodology for PW monitoring. However, apart from various multichannel and multi-site systems proposed in the literature, no true multimodal sensors for PW recording have been proposed yet that acquire PW signals simultaneously from the same measurement site. In this study, a true multimodal PW sensor is presented, which was obtained by integrating a piezoelectric forcecardiography (FCG) sensor and a PPG sensor, thus enabling simultaneous mechanical–optical measurements of PWs from the same site on the body. The novel sensor performance was assessed by measuring the finger PWs of five healthy subjects at rest. The preliminary results of this study showed, for the first time, that a delay exists between the PWs recorded simultaneously by the PPG and FCG sensors. Despite such a delay, the pulse waveforms acquired by the PPG and FCG sensors, along with their first and second derivatives, had very high normalized cross-correlation indices in excess of 0.98. Six well-established morphological parameters of the PWs were compared via linear regression, correlation, and Bland–Altman analyses, which showed that some of these parameters were not in good agreement for all subjects. The preliminary results of this proof-of-concept study must be confirmed in a much larger cohort of subjects. Further investigation is also necessary to shed light on the physical origin of the observed delay between optical and mechanical PW signals. This research paves the way for the development of true multimodal, wearable, integrated sensors and for potential sensor fusion approaches to improve the performance of PW monitoring at various body sites.