The current implementation for continuous, long-term solar spectral irradiance (SSI) monitoring is the Total and Spectral Solar Irradiance Sensor (TSIS-1) Spectral Irradiance Monitor (SIM) that began operations from the International Space Station (ISS) in March 2018 and nominally provides an SSI spectrum every 12 h. Advances in both instrument design and spectral irradiance calibration techniques have resulted in the TSIS-1 SIM achieving higher absolute accuracy than its predecessor instrument in the wavelength range (200–2400 nm). A comprehensive detector-based Spectral Radiometer Facility (SRF) was developed in collaboration with the US National Institute for Standards and Technology (NIST) to ensure the ties to spectral SI standards in power and irradiance. Traceability is achieved via direct laser calibration of a focal plane electrical substitution radiometer (ESR) against a cryogenic radiometer in power and also irradiance responsivity via calibrated apertures. The SIM accuracy definition followed an absolute sensor approach based on a full radiometric measurement equation where component-level performance characterizations and calibrations were quantified with an associated uncertainty error budget and verified by independent measurements for each parameter. Unit-level characterizations were completed over the full operational envelope of external driving factors (e.g., pointing and temperature ranges) and were allowed for the independent parameterization of sub-assembly performance for expected operating conditions. Validation and final instrument end-to-end absolute calibration in the Laboratory for Atmospheric and Space Physics (LASP)-SRF achieved low combined standard uncertainty (uc < 0.25%, k = 1) in spectral irradiance.
Multi-wall vertically aligned carbon nanotubes (VACNTs) are nearly ideal absorbers due to their exceptionally low reflectance over a broad wavelength range. Integrating VACNTs as bolometer absorbers, however, can be difficult due to their high growth temperature and fragile nature. Despite these challenges, we have microfabricated many different types of VACNT bolometers, ranging from cryogenic optical power primary standards to room temperature satellite-based solar irradiance monitors and broadband infrared microbolometers. Advantages our VACNT bolometers provide over the bolometers they replace vary by application, but can be reduced size and time constant, increased absorption, and/or microfabrication instead of hand assembly. Depending on the application and operating conditions, our VACNT bolometers are designed with a variety of thermistors and weak thermal links. The thermistors used include commercial surface mount chips, superconducting transition-edge sensors, and vanadium oxide (VOx). Weak thermal links include silicon nitride (SiNx) membranes, Si bridges, and laser-cut polyimide. We summarize a wide variety of microfabricated bolometers with VACNT absorbers that measure optical power levels spanning over seven orders of magnitude.
12 April 2024 in Journal of Space Weather and Space Climate
The first implementation of NASA’s Total and Spectral Solar Irradiance Sensor (TSIS-1) launched on December 15th, 2017, and was integrated into the International Space Station (ISS) to measure both the total solar irradiance (TSI) and the solar spectral irradiance (SSI). The direct measurement of the SSI is made by the LASP Spectral Irradiance Monitor (SIM) and provides data essential to interpreting how the Earth system responds to solar spectral variability. Extensive advances in TSIS-1 SIM instrument design and new SI-traceable spectral irradiance calibration techniques have resulted in improved absolute accuracy with uncertainties of less than 0.5% over the continuous 200–2400 nm spectral range. Furthermore, improvements in the long-term spectral stability corrections provide lower trend uncertainties in SSI variability measurements. Here we present the early results of the TSIS-1 SIM measurements covering the first 5 years of operations. This time period includes the descending phase of solar cycle 24, the last solar minimum, and the ascending phase of solar cycle 25. The TSIS-1 SIM SSI results are compared to previous measurements both in the absolute scale of the solar spectrum and the time dependence of the SSI variability. The TSIS-1 SIM SSI spectrum shows lower IR irradiance (up to 6% at 2400 nm) and small visible increases (~0.5%) from some previous reference solar spectra. Finally, initial comparisons are made to current NRLSSI2 and SATIRE-S SSI model results and offer opportunities to validate model details both for short-term (solar rotation) spectral variability and, for the first time, the longer-term (near half solar cycle) spectral variability across the solar spectrum from the UV to the IR.
The Solar Radiation and Climate Experiment (SORCE) and Total and Spectral Irradiance Sensor (TSIS‐1) conducted an intercomparison for the two Spectral Irradiance Monitors (SIM) spanning 704 days from 23 March 2018 to 25 February 2020 and permitted 554 time‐matched pairs of observations. This comparison was conducted during the extremely quiescent Solar Cycle 24 minimum, so all observed differences and drifts between the two sensors are instrumental in nature. The TSIS‐1 SIM benefitted from advanced calibration capabilities based on SI standards that were not available during the preflight calibration time period of SORCE. For this reason, a revision of the SORCE SIM absolute scale is appropriate. As expected, wavelength dependent differences in absolute agreement are a function of detector sensitivity and local changes in spectral slope. At the time of the comparison SORCE SIM has been on‐orbit for 17 years while TSIS‐1 observations commenced immediately after a 100‐day outgassing and commissioning period. Peak‐to‐peak absolute scale differences are about 12% with a mean fractional difference of 0.7% ± 2.9%. The greatest scale differences occur at the change‐over between the UV and visible photodiodes in the 310 nm region, and a systematic disagreement is present in the 850–1,600 nm range. A multiplicative scale correction factor has been developed to reconcile the TSIS‐1 and SORCE difference with a wavelength dependent error on the mean typically less than 0.01% derived from every matched pair of observations.
We present the results of a recent, extensive measurement campaign validating the traceability of the solar irradiance record and Earth radiation budget data. The campaign also established future traceability, thus ensuring confidence in the continuing climate-data record. The total solar irradiance radiometer facility (TRF) at the Laboratory for Atmospheric and Space Physics (LASP) Boulder, uses a liquid helium cooled cryogenic radiometer as the reference standard for the validation of spaceflight total solar irradiance (TSI) instrumentation. In 2008 the radiometer was directly compared to the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at a wavelength of 532.12 nm. At TSI power levels, a correction factor of 1.000 306 with an associated standard uncertainty (u) of 0.000 098, was reported for the TRF radiometer scale when using external voltage measurement electronics, and not correcting for cavity heating non-equivalence or cavity absorptance. The TRF radiometer has recently been revalidated at LASP using a POWR calibrated silicon photodiode trap transfer standard named TT4. We report a correction factor of 0.999 787, u = 0.000 285 to align the TRF radiometer scale with the current NIST POWR scale. A new room temperature reference standard radiometer was established. It measured 133 parts per million (ppm) higher than POWR using the same silicon transfer standard as above, and in a separate direct measurement, 168 ppm lower than the TRF radiometer shuttered at 400 s full shutter cycle. The difference agrees within stated uncertainties. A correction of 0.999 867, u = 0.000 247 will align the new radiometer scale with the NIST radiant power scale of POWR.