The climate change that plagues the world is causing extended periods of water shortage. This situation is forcing farmers in the region of Murcia in Spain to modernize their irrigation systems to optimize use of the scarce water they have and seek a circular water economy using the recovered water. Moreover, an associated problem is the need for energy that these facilities require in order to pressurize the required water. The use of photovoltaic generation contributes to the reduction of greenhouse gas (GHG) emissions. Food produced in this region tends to have guaranteed markets in Europe and, geographically, due to the high quality of phytosanitary controls and traceability during their marketing, their optimal cultivation, and selection and labelling is verified, specifying valuable information such as: collection date, origin, the use of organic fertilizers among others. To maintain market access, it is important to continue implementing other environmental improvements, i.e., reductions in either hydro or carbon footprints. Previous studies have failed to include the prospect of environmental use of isolated facilities to replace existing consumption, seeking the monetarization of the facility as well as prioritizing the reduction of GHG. Previous studies have failed to include the perspective of environmental use of isolated photovoltaic installations, based on existing consumption, thus, going beyond the monetarization of the facility, to prioritize the reduction of GHG applied in practice by environmentally sensitized farmers. This study was conducted in an existing facility with great technical complexity and three different sources of water supply, over 1500 plots and an altitude range in plots and reservoirs of more than 400 m.
Hydrogen sulfide (H2S) generated in sewer networks induces corrosion which today constitutes the main cause of deterioration of concrete pipes. Information regarding the H2S concentration inside sewer networks, as well as its control and reduction, has become one of the most important concerns in sanitation systems management nowadays. Modeling sulfide dynamics is the key to understanding corrosion processes. A dynamic model (called EMU-SANETSUL) was developed to calculate the H2S concentration in both the water and the gas phases of the main sewers of the city of Murcia (Spain). The model was calibrated with data from field measurements taken from both the gas phase and wastewater. Samples were taken in the network from 2016 to 2019. The model achieved an accuracy index and error index in the ranges of 57% and 15%, respectively. Empirical equations of reaction are used, and calibration parameters are detailed. The code uses an explicit discretization technique, named the Discrete Volume Element Method (DVEM). A map with the annual average concentration of H2S at the gas phase inside each pipe of the simulated network is presented. Values are compared with the mechanical deterioration inventory from closed-circuit television (CCTV) inspections performed by the Municipal Sanitation Company of the city of Murcia (EMUASA). Mechanical deterioration of pipes has diverse causes, including corrosion of pipes by H2S. Sections with high H2S concentrations that match with mechanical wear can be considered susceptible to being prioritized when rehabilitation works are being planned. Therefore, H2S concentration modeling provides valuable information for asset management of the sewer network.
9 October 2023 in Journal of Environmental Management
The energy required for various processes in the water cycle can have significant economic and environmental impacts. Therefore, efficient energy management in urban water supply systems is crucial for a sustainable operation. By installing energy recovery technologies in these facilities, it is possible to reap the benefits of the infrastructure design by saving energy. In this study, a new methodology to assess the energy recovery at the inlets of district metered areas is presented, considering the city of Murcia (Spain) as case study. This methodology is based on creating a detailed model of city water supply system and calibrating such model with an experimental campaign of measurements. Then, the assessment of the hydraulic potential recovery is analysed through two different energy estimators, one considering the minimum available net head and the other assuming a variable net head. Results show that there are several points where turbines could be installed, most of them recovering in between 1000-5000 kWh, which could be used to cover the yearly energy consumption of about 24-120 m2 of a school or 10-50 traffic lights of such area. Moreover, in some points it could be recovered up to 14500 kWh. Even though these values are not high, the energy recovered could be used for self-consumption of nearby electrical loads, at the time that reduces the pressure in the system, thus leading to leak reductions. Moreover, this kind of energy recovery does not reduce the potential of other proposals for upstream energy recovery, such as replacing pressure reduction valves with turbines instead. The scripts developed to apply the proposed methodology are available in EPANET-Octave file exchange for the researcher community.
This paper reveals reductions of up to 485 t CO2 eq (CO2 equivalent) of greenhouse gas (GHG) emissions of energy origin associated with the water-energy binomial which can be achieved after modernizing and automating a Water User Association (WUA) of over 1780 users with microplots in a total area of 775 ha in southeastern Spain. This case study aims to show how the latest advances in information and communication technologies (ICTs) for precision agriculture are being applied efficiently with the implementation of a Smart Agri system, capable of making improvements through the use of renewable energies (64.49% of the total CO2e- avoided), automation in irrigation water management, by applying adequate governance, use of ICTs (731,014 m3 per water footprint reduction with 20.41% of total CO2 eq of associated electrical origin), hydraulic improvements (283,995 m3 per water footprint reduction, 13.77% of the total CO2 eq of associated electrical origin) and reduction of evaporation in reservoirs (26,022 m3 of water by water footprint reduction with 1.33% of the total CO2 eq electrical origin avoided) that act as batteries to accumulate the daily solar energy and enable watering at night, when irrigation is most efficient. It is important to consider the valuable contribution of these artificial green lungs, not only in terms of food for the European Union, but also as a CO2 eq sink that supports the planet’s GHGs. As shown in this study, this is made possible by the joint governance led by the Water Users Association (WUA) and co-led by different management organizations with the support of ICT.
During a certain period in the history of Spain, in the years of the Second Industrial Revolution, water companies played a very important role in managing a public service as necessary and complex as the supply of drinking water to the population. This article describes the emergence of these companies in the economic framework of the second half of the 19th century, as well as their expansion and territorial distribution, their evolution towards large companies that unified and monopolised the sector and their progressive decline in the 20th century, characterised by an increase in municipal control and influenced by different national and international war conflicts. The data collected in the different statistical yearbooks allows us to study these companies, and identify the characteristics of the modern drinking water system in Spain, together with the importance of foreign investment and the influence of these companies on the economic development of the time.
17 January 2025 in Agua y Territorio / Water and Landscape
The water supply to Cartagena has been a challenge throughout history. From the end of the 19th century, different private companies tried to take advantage of the business opportunity, with The Carthagena Mining & Water C˚ Ltd. standing out among them all. One of the characteristics of the activity developed by the company was its ability to make the most of the water resources of an area with enormous climatic difficulties, adopting technological solutions that maximized the use of the existing water in the environment and which gave rise to a historical heritage of enormous interest. This imperative need to take advantage of the scarce water available, specifically the surface water that occasionally circulated in the area, was the origin of the biological contamination problems that were detected in the city’s water supply.