Water management towards smart cities is an issue increasingly appreciated under financial and environmental sustainability focus in any water sector. The main objective of this research is to disclose the technological breakthroughs associated with water and energy use. A methodology is proposed and applied in a case study to analyze the benefits to develop smart water grids, showing the advantages offered by the development of control measures. The case study showed the positive results, particularly savings of 57 GWh and 100 Mm3 in a period of twelve years when different measures from the common ones were developed for the monitoring and control of water losses in smart water management. These savings contributed to reducing the CO2 emissions to 47,385 t CO2-eq. Finally, in order to evaluate the financial effort and savings obtained in this reference systems (RS) network, the investment required in the monitoring and water losses control in a correlation model case (CMC) was estimated, and, as a consequence, the losses level presented a significant reduction towards sustainable values in the next nine years. Since the pressure control is one of the main issues for the reduction of leakage, an estimation of energy production for Portugal is also presented.
Analyses of possible synergies between energy recovery and water management are essential for achieving sustainable improvements in the performance of irrigation water networks. Improving the energy efficiency of water systems by hydraulic energy recovery is becoming an inevitable trend for energy conservation, emissions reduction, and the increase of profit margins as well as for environmental requirements. This paper presents the state of the art of hydraulic energy generation in drinking and irrigation water networks through an extensive review and by analyzing the types of machinery installed, economic and environmental implications of large and small hydropower systems, and how hydropower can be applied in water distribution networks (drinking and irrigation) where energy recovery is not the main objective. Several proposed solutions of energy recovery by using hydraulic machines increase the added value of irrigation water networks, which is an open field that needs to be explored in the near future.
Nowadays, in the management of water distribution networks (WDNs), particular attention is paid to digital transition and the improvement of the energy efficiency of these systems. New technologies have been developed in the recent years and their implementation can be crucial to achieve a sustainable level of water networks, namely, in water and energy losses. In particular, Digital Twins (DT) represents a very innovative technology, which relies on the integration of virtual network models, optimization algorithms, real time data collection, and smart actuators information with Geographic Information System (GIS) data. This research defines a new methodology for an efficient application of DT expertise within water distribution networks. Assuming a DMA of a real water distribution network as a case study, it was demonstrated that a fast detection of leakage along with an optimal setting of pressure control valves by means of DT together with an optimization procedure can ensure up to 28% of water savings, contributing to significantly increase the efficiency of the whole system.
The present paper deals with a hydraulic jump study, characterization and numerical modeling. Hydraulic jumps constitute a common phenomenon in the hydraulics of open channels that increases the shear stress on streambeds, so promoting their erosion. A three-dimensional computational fluid dynamics model is proposed to analyze hydraulic jumps in horizontal smooth rectangular prismatic open-air channels (i.e., the so-called classical hydraulic jump). Turbulence is modeled using three widely used Reynolds-averaged Navier–Stokes (RANS) models, namely: Standard k − ɛ, RNG k − ɛ, and SST k − ω. The coexistence of two fluids and the definition of an interface between them are treated using a volume method in Cartesian grids of several element sizes. An innovative way to deal with the outlet boundary condition that allows the size of the simulated domain to be reduced is presented. A case study is conducted for validation purposes (FR1 ∼ 6.10, Re1 ∼ 3.5·105): several variables of interest are computed (sequent depths, efficiency, roller length, free surface profile, etc.) and compared to previous studies, achieving accuracies above 98% in all cases. In the light of the results, the model can be applied to real-life cases of design of hydraulic structures.
Water irrigation systems are required to provide adequate pressure levels in any sort of network. Quite frequently, this requirement is achieved by using pressure reducing valves (PRVs). Nevertheless, the possibility of using hydraulic machines to recover energy instead of PRVs could reduce the energy footprint of the whole system. In this research, a new methodology is proposed to help water managers quantify the potential energy recovering of an irrigation water network with adequate conditions of topographies distribution. EPANET has been used to create a model based on probabilities of irrigation and flow distribution in real networks. Knowledge of the flows and pressures in the network is necessary to perform an analysis of economic viability. Using the proposed methodology, a case study has been analyzed in a typical Mediterranean region and the potential available energy has been estimated. The study quantifies the theoretical energy recoverable if hydraulic machines were installed in the network. Particularly, the maximum energy potentially recovered in the system has been estimated up to 188.23 MWh/year) with a potential saving of non-renewable energy resources (coal and gas) of CO2 137.4 t/year.