Qiufang Zhang

Dr. Qiufang Zhang

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JHJinghan He
Jinghan He
YLYiping Luo
Yiping Luo
MLMeng Li
Meng Li
YZYongjie Zhang
Yongjie Zhang
YXYin Xu
Yin Xu
GLGuomin Luo
Guomin Luo

8 July 2021 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
QZQiufang Zhang
Qiufang Zhang
JHJinghan He
Jinghan He
YXYin Xu
Yin Xu
ZHZeqi Hong
Zeqi Hong
YCYing Chen
Ying Chen
KSKai Strunz
Kai Strunz
Control design and stability analysis of direct-driven permanent magnet synchronous generator (PMSG)-based wind energy conversion systems (WECSs) typically involve extensive time-domain simulations and frequency-domain analyses. Those studies rely on accurate and computationally efficient models of WECSs. Detailed switching models can accurately describe the transients of power-electronic converters, but they suffer from low computational efficiency due to the repeated switching events. In this paper, a numerically efficient model is developed for a direct-driven PMSG-based WECS. Analytical and parametric average-value modeling techniques are applied to its switching subsystems, including a 12-pulse diode rectifier, a three-phase-interleaved boost converter, a dual three-phase voltage source inverter (VSI), and a crowbar circuit. The average-value models (AVMs) improve the simulation efficiency by representing the terminal characteristics of switching subsystems with a set of algebraic equations. In addition, numerical linearization techniques can be directly employed for them to obtain frequency-domain characteristics. The proposed model is verified against the detailed switching model and existing AVM in MATLAB/Simulink. It is shown to have excellent accuracy in both time-domain and frequency-domain studies while maintaining high computational efficiency.

19 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
QZQiufang Zhang
Qiufang Zhang
ZSZheng Shi
Zheng Shi
YWYing Wang
Ying Wang
JHJinghan He
Jinghan He
YXYin Xu
Yin Xu
MLMeng Li
Meng Li
Short-circuit faults in a receiving-end power system can lead to blocking events of the feed-in high-voltage direct-current (HVDC) systems, which may further result in system instability. However, security assessment methods based on the transient stability (TS) simulation can hardly catch the fault propagation phenomena between AC and DC subsystems. Moreover, effective emergency control strategies are needed to prevent such undesired cascading events. This paper focuses on power systems with multi-infeed HVDCs. An on-line security assessment method based on the electromagnetic transient (EMT)-TS hybrid simulation is proposed. DC and AC subsystems are modeled in EMTDC/PSCAD and PSS/E, respectively. In this way, interactions between AC and DC subsystems can be well reflected. Meanwhile, high computational efficiency is maintained for the on-line application. In addition, an emergency control strategy is developed, which coordinates multiple control resources, including HVDCs, pumped storages, and interruptible loads, to maintain the security and stability of the receiving-end system. The effectiveness of the proposed methods is verified by numerical simulations on two actual power systems in China. The simulation results indicate that the EMT-TS hybrid simulation can accurately reflect the fault propagation phenomena between AC and DC subsystems, and the coordinated emergency control strategy can work effectively to maintain the security and stability of systems.