Bernhard Akstaller

Mr. Bernhard Akstaller

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Journal of Instrumentation
Verified
Journal Article
Closed access
BABernhard Akstaller
Bernhard Akstaller
SSS. Schreiner
S. Schreiner
FHF. Hofmann
F. Hofmann
PMP. Meyer
P. Meyer
PNP. Neumayer
P. Neumayer
SFS. Funk
S. Funk
A single-shot x-ray phase-contrast imaging technique with short exposure time allows to capture sharp images of fast dynamic processes despite low absorption contrast. We demonstrate the capabilities of a robust single-shot grating-based phase-contrast imaging setup at the Petawatt High-Energy Laser for Heavy Ion EXperiments (PHELIX) at the GSI Helmholtzzentrum für Schwerionenforschung GmbH. A static test sample was imaged at 47-fold magnification using a laser-driven high-energy x-ray backlighter source. The retrieved transmission and phase-contrast images yield reproducible results. The reconstructed differential phase-images are quantitatively explained. In addition to the phase-images, propagation signatures are found in the data and used for result verification. The obtained results demonstrate the capabilities of the grating setup which can be used to image microscopic dynamic processes in high-energy density plasma experiments at PHELIX or similar high-power laser facilities.

15 March 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
AWAndreas Wolf
Andreas Wolf
BABernhard Akstaller
Bernhard Akstaller
Silvia CipicciaSilvia Cipiccia
Silvia Cipiccia
SFSilja Flenner
Silja Flenner
JHJohannes Hagemann
Johannes Hagemann
SFStefan Funk
Stefan Funk
The advent of hard X-ray free-electron lasers enables nanoscopic X-ray imaging with sub-picosecond temporal resolution. X-ray grating interferometry offers a phase-sensitive full-field imaging technique where the phase retrieval can be carried out from a single exposure alone. Thus, the method is attractive for imaging applications at X-ray free-electron lasers where intrinsic pulse-to-pulse fluctuations pose a major challenge. In this work, the single-exposure phase imaging capabilities of grating interferometry are characterized by an implementation at the I13-1 beamline of Diamond Light Source (Oxfordshire, UK). For comparison purposes, propagation-based phase contrast imaging was also performed at the same instrument. The characterization is carried out in terms of the quantitativeness and the contrast-to-noise ratio of the phase reconstructions as well as via the achievable spatial resolution. By using a statistical image reconstruction scheme, previous limitations of grating interferometry regarding the spatial resolution can be mitigated as well as the experimental applicability of the technique.

5 September 2021 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
SSstephan schreiner
stephan schreiner
BABernhard Akstaller
Bernhard Akstaller
LDLisa Dietrich
Lisa Dietrich
PMPascal Meyer
Pascal Meyer
PNPaul Neumayer
Paul Neumayer
SFStefan Funk
Stefan Funk
X-ray backlighters allow the capture of sharp images of fast dynamic processes due to extremely short exposure times. Moiré imaging enables simultaneously measuring the absorption and differential phase-contrast (DPC) of these processes. Acquiring images with one single shot limits the X-ray photon flux, which can result in noisy images. Increasing the photon statistics by repeating the experiment to gain the same image is not possible if the investigated processes are dynamic and chaotic. Furthermore, to reconstruct the DPC and transmission image, an additional measurement captured in absence of the object is required. For these reference measurements, shot-to-shot fluctuations in X-ray spectra and a source position complicate the averaging of several reference images for noise reduction. Here, two approaches of processing multiple reference images in combination with one single object image are evaluated regarding the image quality. We found that with only five reference images, the contrast-to-noise ratio can be improved by approximately 13% in the DPC image. This promises improvements for short-exposure single-shot acquisitions of rapid processes, such as laser-produced plasma shock-waves in high-energy density experiments at backlighter X-ray sources such as the PHELIX high-power laser facility.

2 August 2019 in Journal of Instrumentation
Verified
Journal Article
Closed access
MSMax Schuster
Max Schuster
VLVeronika Ludwig
Veronika Ludwig
BABernhard Akstaller
Bernhard Akstaller
MSM. Seifert
M. Seifert
AWA. Wolf
A. Wolf
GAG. Anton
G. Anton

3 July 2020 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
MSMaria Seifert
Maria Seifert
MWMareike Weule
Mareike Weule
Silvia CipicciaSilvia Cipiccia
Silvia Cipiccia
SFSilja Flenner
Silja Flenner
JHJohannes Hagemann
Johannes Hagemann
BABernhard Akstaller
Bernhard Akstaller
For imaging events of extremely short duration, like shock waves or explosions, it is necessary to be able to image the object with a single-shot exposure. A suitable setup is given by a laser-induced X-ray source such as the one that can be found at GSI (Helmholtzzentrum für Schwerionenforschung GmbH) in Darmstadt (Society for Heavy Ion Research), Germany. There, it is possible to direct a pulse from the high-energy laser Petawatt High Energy Laser for Heavy Ion eXperiments (PHELIX) on a tungsten wire to generate a picosecond polychromatic X-ray pulse, called backlighter. For grating-based single-shot phase-contrast imaging of shock waves or exploding wires, it is important to know the weighted mean energy of the X-ray spectrum for choosing a suitable setup. In propagation-based phase-contrast imaging the knowledge of the weighted mean energy is necessary to be able to reconstruct quantitative phase images of unknown objects. Hence, we developed a method to evaluate the weighted mean energy of the X-ray backlighter spectrum using propagation-based phase-contrast images. In a first step wave-field simulations are performed to verify the results. Furthermore, our evaluation is cross-checked with monochromatic synchrotron measurements with known energy at Diamond Light Source (DLS, Didcot, UK) for proof of concepts.

1 July 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
SSstephan schreiner
stephan schreiner
CRConstantin Rauch
Constantin Rauch
BABernhard Akstaller
Bernhard Akstaller
PBPaulina Bleuel
Paulina Bleuel
EFEric Fröjdh
Eric Fröjdh
SFStefan Funk
Stefan Funk
Laser-driven x-ray backlighting can be used to image fast dynamic processes like the propagation of laser-driven shock waves in matter. We demonstrate and evaluate the feasibility of operating the JUNGFRAU detector designed by PSI, a direct detecting x-ray detector, in environments with extreme electromagnetic pulses. The electromagnetic pulse-protective housing is specifically designed for this detector and optimized for pump-probe experiments at the Petawatt High-Energy Laser for Heavy Ion EXperiments (PHELIX) facility at the GSI Helmholtzzentrum für Schwerionenforschung GmbH. The beryllium x-ray entrance window of the protective housing has a high x-ray transmission of 94% at 8 keV. Measurements have shown that the housing simultaneously provides a relative damping of the electromagnetic field on average higher than 1000 in the frequency range of 100 MHz to 5 GHz. The results demonstrate the feasibility of operating digital detectors in experiments where strong electromagnetic pulses are present.