Max Schuster

Mr. Max Schuster

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
MSMaria Seifert
Maria Seifert
MGMichael Gallersdoerfer
Michael Gallersdoerfer
VLVeronika Ludwig
Veronika Ludwig
MSMax Schuster
Max Schuster
FHFlorian Horn
Florian Horn
GAGisela Anton
Gisela Anton
X-ray phase-contrast imaging is a promising method for medical imaging and non-destructive testing. Information about the attenuation, small-angle scattering and phase-shifting properties of an object can be gained simultaneously in three image modalities using a Talbot–Lau interferometer. This is a highly sensitive approach for retrieving this information. Nevertheless, until now, Talbot–Lau interferometry has been a time-consuming process due to image acquisition by phase-stepping procedures. Thus, methods to accelerate the image acquisition process in Talbot–Lau interferometry would be desirable. This is especially important for medical applications to avoid motion artifacts. In this work, the Talbot–Lau interferometry is combined with the moiré imaging approach. Firstly, the reconstruction algorithm of moiré imaging is improved compared to the standard reconstruction methods in moiré imaging that have been published until now. Thus, blurring artifacts resulting from the reconstruction in the frequency domain can be reduced. Secondly, the improved reconstruction algorithm allows for reducing artifacts in the reconstructed images resulting from inhomogeneities of the moiré pattern in large fields of view. Hence, the feasibility of differential phase-contrast imaging with regard to the integration into workflows in medical imaging and non-destructive testing is improved considerably. New fields of applications can be gained due to the accelerated imaging process—for example, live imaging in medical applications.

15 March 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
AWAndreas Wolf
Andreas Wolf
BABernhard Akstaller
Bernhard Akstaller
Silvia CipicciaSilvia Cipiccia
Silvia Cipiccia
SFSilja Flenner
Silja Flenner
JHJohannes Hagemann
Johannes Hagemann
SFStefan Funk
Stefan Funk
The advent of hard X-ray free-electron lasers enables nanoscopic X-ray imaging with sub-picosecond temporal resolution. X-ray grating interferometry offers a phase-sensitive full-field imaging technique where the phase retrieval can be carried out from a single exposure alone. Thus, the method is attractive for imaging applications at X-ray free-electron lasers where intrinsic pulse-to-pulse fluctuations pose a major challenge. In this work, the single-exposure phase imaging capabilities of grating interferometry are characterized by an implementation at the I13-1 beamline of Diamond Light Source (Oxfordshire, UK). For comparison purposes, propagation-based phase contrast imaging was also performed at the same instrument. The characterization is carried out in terms of the quantitativeness and the contrast-to-noise ratio of the phase reconstructions as well as via the achievable spatial resolution. By using a statistical image reconstruction scheme, previous limitations of grating interferometry regarding the spatial resolution can be mitigated as well as the experimental applicability of the technique.

5 September 2021 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
SSstephan schreiner
stephan schreiner
BABernhard Akstaller
Bernhard Akstaller
LDLisa Dietrich
Lisa Dietrich
PMPascal Meyer
Pascal Meyer
PNPaul Neumayer
Paul Neumayer
SFStefan Funk
Stefan Funk
X-ray backlighters allow the capture of sharp images of fast dynamic processes due to extremely short exposure times. Moiré imaging enables simultaneously measuring the absorption and differential phase-contrast (DPC) of these processes. Acquiring images with one single shot limits the X-ray photon flux, which can result in noisy images. Increasing the photon statistics by repeating the experiment to gain the same image is not possible if the investigated processes are dynamic and chaotic. Furthermore, to reconstruct the DPC and transmission image, an additional measurement captured in absence of the object is required. For these reference measurements, shot-to-shot fluctuations in X-ray spectra and a source position complicate the averaging of several reference images for noise reduction. Here, two approaches of processing multiple reference images in combination with one single object image are evaluated regarding the image quality. We found that with only five reference images, the contrast-to-noise ratio can be improved by approximately 13% in the DPC image. This promises improvements for short-exposure single-shot acquisitions of rapid processes, such as laser-produced plasma shock-waves in high-energy density experiments at backlighter X-ray sources such as the PHELIX high-power laser facility.

2 August 2019 in Journal of Instrumentation
Verified
Journal Article
Closed access
MSMax Schuster
Max Schuster
VLVeronika Ludwig
Veronika Ludwig
BABernhard Akstaller
Bernhard Akstaller
MSM. Seifert
M. Seifert
AWA. Wolf
A. Wolf
GAG. Anton
G. Anton

3 July 2020 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
MSMaria Seifert
Maria Seifert
MWMareike Weule
Mareike Weule
Silvia CipicciaSilvia Cipiccia
Silvia Cipiccia
SFSilja Flenner
Silja Flenner
JHJohannes Hagemann
Johannes Hagemann
BABernhard Akstaller
Bernhard Akstaller
For imaging events of extremely short duration, like shock waves or explosions, it is necessary to be able to image the object with a single-shot exposure. A suitable setup is given by a laser-induced X-ray source such as the one that can be found at GSI (Helmholtzzentrum für Schwerionenforschung GmbH) in Darmstadt (Society for Heavy Ion Research), Germany. There, it is possible to direct a pulse from the high-energy laser Petawatt High Energy Laser for Heavy Ion eXperiments (PHELIX) on a tungsten wire to generate a picosecond polychromatic X-ray pulse, called backlighter. For grating-based single-shot phase-contrast imaging of shock waves or exploding wires, it is important to know the weighted mean energy of the X-ray spectrum for choosing a suitable setup. In propagation-based phase-contrast imaging the knowledge of the weighted mean energy is necessary to be able to reconstruct quantitative phase images of unknown objects. Hence, we developed a method to evaluate the weighted mean energy of the X-ray backlighter spectrum using propagation-based phase-contrast images. In a first step wave-field simulations are performed to verify the results. Furthermore, our evaluation is cross-checked with monochromatic synchrotron measurements with known energy at Diamond Light Source (DLS, Didcot, UK) for proof of concepts.

1 May 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
SSstephan schreiner
stephan schreiner
CRC. Rauch
C. Rauch
BABernhard Akstaller
Bernhard Akstaller
PBP. Bleuel
P. Bleuel
EFErik Fröjdh
Erik Fröjdh
SFS. Funk
S. Funk
Laser-driven shock waves in matter propagate with multiple kilometers per second and therefore require sources like a laser-driven backlighter, which emit the X-rays within picoseconds, to be able to capture sharp images. The small spatial extent of shocks in low-density materials pose challenges on the imaging setup. In this work, we present a design process for a single-shot X-ray phase-contrast imaging system geared towards these objects, consisting of a two-grating Talbot interferometer and a digital X-ray detector. This imaging system is optimized with respect to the detectable refraction angle of the X-rays induced by an object, which implies a high phase sensitivity. Therefore, an optimization parameter is defined that considers experimental constraints such as the limited number of photons, the required magnification, the size and spectrum of the X-ray source, and the visibility of the moiré fringes. In this way, a large parameter space is sampled and a suitable imaging system is chosen. During a campaign at the PHELIX high-power laser facility a static test sample was imaged which is used to benchmark the optimization process and the imaging system under real conditions. The results show good agreement with the predicted performance, which demonstrates the reliability of the presented design process. Likewise, the process can be adapted to other types of laser experiments or X-ray sources and is not limited to the application presented here.