The hydrothermal performance of multiple semi-twisted tape inserts inside a heat exchanger pipe is numerically examined in three-dimensions. This study aims to find the optimum case for having the highest heat transfer enhancement with the lowest friction factor using nanofluid (Al2O3/water). A performance evaluation criterion (PEC) is defined to characterize the performance based on both friction factor and heat transfer. It was found that increasing the number of semi-twisted tapes increases the number of swirl flow streams and leads to an enhancement in the local Nusselt number as well as the friction factor. The average Nusselt number increases from 15.13 to 28.42 and the average friction factor enhances from 0.022 to 0.052 by increasing the number of the semi-twisted tapes from 0 to 4 for the Reynolds number of 1000 for the base fluid. By using four semi-twisted tapes, the average Nusselt number increases from 12.5 to 28.5, while the friction factor reduces from 0.155 to 0.052 when the Reynolds number increases from 250 to 1000 for the base fluid. For the Reynolds number of 1000, the increase in nanofluid concentration from 0 to 3% improves the average Nusselt number and friction factor by 6.41% and 2.29%, respectively. The highest PEC is equal to 1.66 and belongs to the Reynolds number of 750 using four semi-twisted tape inserts with 3% nanoparticles. This work offers instructions to model an advanced design of twisted tape integrated with tubes using multiple semi-twisted tapes, which helps to provide a higher amount of energy demand for solar applications.
5 April 2019 in Journal of Materials Science: Materials in Electronics
This study aims to study the discharging process to verify the influence of geometry modifications and heat transfer flow (HTF) patterns on the performance of a vertical triplex-tube latent heat container. The phase change material (PCM) is included in the middle tube, where the geometry is modified using single or multi-internal frustum tubes instead of straight tubes to enhance the discharging rate. The effects of the HTF flow direction, which is considered by the gravity and opposite-gravity directions, are also examined in four different cases. For the optimal geometry, three scenarios are proposed, i.e., employing a frustum tube for the middle tube, for the inner tube, and at last for both the inner and middle tubes. The effects of various gap widths in the modified geometries are investigated. The results show the advantages of using frustum tubes in increasing the discharging rate and reducing the solidification time compared with that of the straight tube unit due to the higher natural convection effect by proper utilization of frustum tubes. The study of the HTF pattern shows that where the HTF direction in both the inner and outer tubes are in the gravity direction, the maximum discharging rate can be achieved. For the best configuration, the discharge time is reduced negligibly compared with that for the system with straight tubes which depends on the dimensions of the PCM domain.
The safe and efficient operation of the integrated energy system is severely hampered by a number of unpredictable elements, such as the output of renewable energy sources, the cost of energy purchases, and full demand response (IES). The effectiveness and excellence of the integrated energy system scheduling method can be increased with advanced modeling of unpredictable aspects. Thus, the IES robust stochastic optimisation model is constructed and solved with the hybrid shuffled frog-leaping and local search (HSFLA–LS) algorithm. Finally, a simulation analysis considering the uncertainty of energy purchase price based on the hybrid SFLA–LS algorithm is reduced by USD 1.63 (0.64%) and USD 3.34 (1.3%), compared to PSO and GA, respectively. In addition, the time taken to execute the SFLA–LS algorithm for the program is reduced by 1.886 s (1.59%), and 3.117 s (2.7%), compared to PSO and GA, respectively. The findings demonstrate that the suggested approach can lower system running expenses, and achieve the coordination and optimization of economy and robustness.
20 March 2021 in International Journal of Electronics
The microgrid power plant contains a large number of power electronic converters, which inevitably produce power quality problems such as harmonic noise and voltage fluctuations. Harmonics noise is produced excessive heat and reduce the life of the equipment. In this paper, the control strategy of a combination of the bidirectional DC/DC and DC/AC device to integrate supercapacitor and Active Power Filter is proposed. The detail of the mathematical model of the working principle of combination and analyzes the structural characteristics and the switching modes of power regulation and harmonic control logic is provided. The simulation results show that the combined device can perform the functions of power smoothness, reactive power compensation and harmonic control according to the needs, which verifies the rationality and effectiveness of the combined equipment operation.