Ahmed Abdalla

Dr. Ahmed Abdalla


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2018 in Measurement and Control
Verified
Journal Article
Open access
PDF file
AAAhmed Abdalla
Ahmed Abdalla
MFMoneer Faraj
Moneer Faraj
FSFahmi Samsuri
Fahmi Samsuri
DRDamhuji Rifai
Damhuji Rifai
KAKharudin Ali
Kharudin Ali
Y. Al-DouriY. Al-Douri
Y. Al-Douri
Eddy current testing plays an important role in numerous industries, particularly in material coating, nuclear and oil and gas. However, the eddy current testing technique still needs to focus on the details of probe structure and its application. This paper presents an overview of eddy current testing technique and the probe structure design factors that affect the accuracy of crack detection. The first part focuses on the development of different types of eddy current testing probes and their advantages and disadvantages. A review of previous studies that examined testing samples, eddy current testing probe structures and a review of factors contributing to eddy current signals is also presented. The second part mainly comprised an in-depth discussion of the lift-off effect with particular consideration of ensuring that defects are correctly measured, and the eddy current testing probes are optimized. Finally, a comprehensive review of previous studies on the application of intelligent eddy current testing crack detection in non destructive eddy current testing is presented.

26 February 2016 in Sensors
Verified
Journal Article
Open access
PDF file
DRDamhuji Rifai
Damhuji Rifai
AAAhmed Abdalla
Ahmed Abdalla
KAKharudin Ali
Kharudin Ali
RRRamdan Razali
Ramdan Razali
Non-destructive eddy current testing (ECT) is widely used to examine structural defects in ferromagnetic pipe in the oil and gas industry. Implementation of giant magnetoresistance (GMR) sensors as magnetic field sensors to detect the changes of magnetic field continuity have increased the sensitivity of eddy current techniques in detecting the material defect profile. However, not many researchers have described in detail the structure and issues of GMR sensors and their application in eddy current techniques for nondestructive testing. This paper will describe the implementation of GMR sensors in non-destructive testing eddy current testing. The first part of this paper will describe the structure and principles of GMR sensors. The second part outlines the principles and types of eddy current testing probe that have been studied and developed by previous researchers. The influence of various parameters on the GMR measurement and a factor affecting in eddy current testing will be described in detail in the third part of this paper. Finally, this paper will discuss the limitations of coil probe and compensation techniques that researchers have applied in eddy current testing probes. A comprehensive review of previous studies on the application of GMR sensors in non-destructive eddy current testing also be given at the end of this paper.

6 May 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
Muhammad Shahzad NazirMuhammad Shahzad Nazir
Muhammad Shahzad Nazir
Fahad AlturiseFahad Alturise
Fahad Alturise
SASami Alshmrany
Sami Alshmrany
NJNazir Hafiz Muhammad Jamsheed
Nazir Hafiz Muhammad Jamsheed
MQM Qammar
M Qammar
Ziad AliZiad Ali
Ziad Ali
To sustain a clean environment by reducing fossil fuels-based energies and increasing the integration of renewable-based energy sources, i.e., wind and solar power, have become the national policy for many countries. The increasing demand for renewable energy sources, such as wind, has created interest in the economic and technical issues related to the integration into the power grids. Having an intermittent nature and wind generation forecasting is a crucial aspect of ensuring the optimum grid control and design in power plants. Accurate forecasting provides essential information to empower grid operators and system designers in generating an optimal wind power plant, and to balance the power supply and demand. In this paper, we present an extensive review of wind forecasting methods and the artificial neural network (ANN) prolific in this regard. The instrument used to measure wind assimilation is analyzed and discussed, accurately, in studies that were published from May 1st, 2014 to May 1st, 2018. The results of the review demonstrate the increased application of ANN into wind power generation forecasting. Considering the component limitation of other systems, the trend of deploying the ANN and its hybrid systems are more attractive than other individual methods. The review further revealed that high forecasting accuracy could be achieved through proper handling and calibration of the wind-forecasting instrument and method.

13 March 2017 in Sensors
Verified
Journal Article
Open access
PDF file
DRDamhuji Rifai
Damhuji Rifai
AAAhmed Abdalla
Ahmed Abdalla
RRRamdan Razali
Ramdan Razali
KAKharudin Ali
Kharudin Ali
MFMoneer Faraj
Moneer Faraj
The use of the eddy current technique (ECT) for the non-destructive testing of conducting materials has become increasingly important in the past few years. The use of the non-destructive ECT plays a key role in the ensuring the safety and integrity of the large industrial structures such as oil and gas pipelines. This paper introduce a novel ECT probe design integrated with the distributed ECT inspection system (DSECT) use for crack inspection on inner ferromagnetic pipes. The system consists of an array of giant magneto-resistive (GMR) sensors, a pneumatic system, a rotating magnetic field excitation source and a host PC acting as the data analysis center. Probe design parameters, namely probe diameter, an excitation coil and the number of GMR sensors in the array sensor is optimized using numerical optimization based on the desirability approach. The main benefits of DSECT can be seen in terms of its modularity and flexibility for the use of different types of magnetic transducers/sensors, and signals of a different nature with either digital or analog outputs, making it suited for the ECT probe design using an array of GMR magnetic sensors. A real-time application of the DSECT distributed system for ECT inspection can be exploited for the inspection of 70 mm carbon steel pipe. In order to predict the axial and circumference defect detection, a mathematical model is developed based on the technique known as response surface methodology (RSM). The inspection results of a carbon steel pipe sample with artificial defects indicate that the system design is highly efficient.

14 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Yaseen Ahmed AlsumaidaeeYaseen Ahmed Alsumaidaee
Yaseen Ahmed Alsumaidaee
CYCHONG TAK YAW
CHONG TAK YAW
JKJohnny Koh
Johnny Koh
STSieh Kiong Tiong
Sieh Kiong Tiong
CCChai Phing Chen
Chai Phing Chen
ARAvinash Ashwin Raj
Avinash Ashwin Raj
The damaging effects of corona faults have made them a major concern in metal-clad switchgear, requiring extreme caution during operation. Corona faults are also the primary cause of flashovers in medium-voltage metal-clad electrical equipment. The root cause of this issue is an electrical breakdown of the air due to electrical stress and poor air quality within the switchgear. Without proper preventative measures, a flashover can occur, resulting in serious harm to workers and equipment. As a result, detecting corona faults in switchgear and preventing electrical stress buildup in switches is critical. Recent years have seen the successful use of Deep Learning (DL) applications for corona and non-corona detection, owing to their autonomous feature learning capability. This paper systematically analyzes three deep learning techniques, namely 1D-CNN, LSTM, and 1D-CNN-LSTM hybrid models, to identify the most effective model for detecting corona faults. The hybrid 1D-CNN-LSTM model is deemed the best due to its high accuracy in both the time and frequency domains. This model analyzes the sound waves generated in switchgear to detect faults. The study examines model performance in both the time and frequency domains. In the time domain analysis (TDA), 1D-CNN achieved success rates of 98%, 98.4%, and 93.9%, while LSTM obtained success rates of 97.3%, 98.4%, and 92.4%. The most suitable model, the 1D-CNN-LSTM, achieved success rates of 99.3%, 98.4%, and 98.4% in differentiating corona and non-corona cases during training, validation, and testing. In the frequency domain analysis (FDA), 1D-CNN achieved success rates of 100%, 95.8%, and 95.8%, while LSTM obtained success rates of 100%, 100%, and 100%. The 1D-CNN-LSTM model achieved a 100%, 100%, and 100% success rate during training, validation, and testing. Hence, the developed algorithms achieved high performance in identifying corona faults in switchgear, particularly the 1D-CNN-LSTM model due to its accuracy in detecting corona faults in both the time and frequency domains.
1

13 May 2021 in Journal of Energy Resources Technology
Verified
Journal Article
Closed access
PDF file
AAAhmed Abdalla
Ahmed Abdalla
Muhammad Shahzad NazirMuhammad Shahzad Nazir
Muhammad Shahzad Nazir
TZTIEZHU ZHU
TIEZHU ZHU
Mohit BajajMohit Bajaj
Mohit Bajaj
Sanjeevikumar PadmanabanSanjeevikumar Padmanaban
Sanjeevikumar Padmanaban
LYLiu Yao