Markel Dieguez-Pereira

Dr. Markel Dieguez-Pereira

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Implant Dentistry
Verified
Journal Article
Closed access
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
ÁÁÁngel Md Álvarez-Arenal
Ángel Md Álvarez-Arenal
FGFrancisco Javier Bseng Gil-Mur
Francisco Javier Bseng Gil-Mur
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
DCDavid Chavarri-Prado
David Chavarri-Prado
MDMarkel Dieguez-Pereira
Markel Dieguez-Pereira
Purpose: To evaluate the micromobility of dental implants under occlusal loading in relation to stability measurements of resonance frequency analysis and insertion torque. Materials and Methods: The sample comprised of 24 implants inserted in 12 fresh cow ribs. Insertion torque and Osstell implant stability quotient (ISQ) measurements were recorded. An “ad hoc” acrylic premolar was made on a temporary abutment and screwed to each implant, and a force of 100 N was subsequently applied at an angle of 6 degrees. Implant micromotion was measured using a Questar microscope with a resolution of 2 μm and an image analysis program. Results: Data show a statistically significant inverse correlation between the ISQ values and implant micromotion under a load of 100 N (R2 = 0.86, P < 0.0001). The same relationship is found between insertion torque and implant micromotion, although the relationship is linear up to 34 N·cm and becomes exponential for higher values (R2 = 0.78, P < 0.0001). A direct correlation is established between insertion torque and ISQ values. Conclusion: There is an inverse relationship between both ISQ and insertion torque values and implant micromotion under a load of 100 N.

1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
EPEsteban Pérez-Pevida
Esteban Pérez-Pevida
DCDavid Chavarri-Prado
David Chavarri-Prado
MDMarkel Dieguez-Pereira
Markel Dieguez-Pereira
AEAlejandro Estrada-Martínez
Alejandro Estrada-Martínez
OMOier Montalbán-Vadillo
Oier Montalbán-Vadillo
AJAntonio Jiménez-Garrudo
Antonio Jiménez-Garrudo
Background and Objective. Marginal bone loss around dental implants is one of the most prevalent complication, and its biomechanical impact may be critical for treatment prognosis. The objective of this study was to evaluate the influence of marginal bone loss around dental implants in the occlusal load transfer to the bone in terms of magnitude of stress and strain and distribution of such transferred stress. Methods. Three models of a single internal connection bone level‐type implant inserted into a posterior mandible bone section were constructed using a 3D finite element software: one control model without marginal bone loss and two test models, both with a circumferential peri‐implant bone defect, one with a 3 mm high defect and the other one 6 mm high. A 150 N static load was tested on the central fossa at 6° relative to the axial axis of the implant. Results. The results showed differences in the magnitude of strain and stress transferred to the bone between models, being the higher strain found in the trabecular bone around the implant with greater marginal bone loss. Stress distribution differed between models, being concentrated at the cortical bone in the control model and at the trabecular bone in the test models. Conclusion. Marginal bone loss around dental implants under occlusal loading influences the magnitude and distribution of the stress transferred and the deformation of peri‐implant bone, being higher as the bone loss increases.

1 January 2020 in BioMed Research International
Verified
Journal Article
Open access
PDF file
MDMarkel Dieguez-Pereira
Markel Dieguez-Pereira
DCDavid Chávarri-Prado
David Chávarri-Prado
AEAlejandro Estrada-Martínez
Alejandro Estrada-Martínez
EPEsteban Pérez-Pevida
Esteban Pérez-Pevida
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
Objective. Long‐term clinical data on the success and complication rates of monolithic or minimally veneered zirconia implant‐supported restorations are lacking. Hence, the purpose of this retrospective clinical study was to analyze the complications of monolithic or partially veneered zirconia implant‐supported restorations up to 5 years follow‐up. Material and Methods. Single crowns, bridges, and full‐arch rehabilitations were included. The selection process was achieved by reviewing data from the prosthetic laboratory and excluding cases in which zirconium and full‐ceramic coating restorations were used. A total of 154 restorations were included (82 monolithic and 72 with buccal ceramic stratification). All the complications encountered, and the solutions applied, were explained. Results. A total of 93 restorative units had a follow‐up of between 24 and 60 months, and 61 restoration units had a follow‐up of between 12 and 24 months. A total of 7 complications were encountered (14.58% of cases; 95.45% per prosthetic unit). The technical complication rate was 2.08% (one case of minor chipping in one prosthetic unit); regarding the mechanical complications, four decementations (8.33% of the cases) and two screw loosening (4.17% of the cases) were encountered. Conclusions. Considering the limitations of this study, it can be concluded that monolithic or partially veneered zirconia implant‐supported restorations have a good clinical behavior during a follow‐up period of up to 5 years.

20 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
NANerea Arlucea
Nerea Arlucea
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
MDMarkel Dieguez-Pereira
Markel Dieguez-Pereira
MFMiquel Punset Fuste
Miquel Punset Fuste
MMMeritxell Molmeneu Molmeneu
Meritxell Molmeneu Molmeneu
ÁÁÁngel Álvarez-Arenal
Ángel Álvarez-Arenal
The present experimental trial uses two types of dental implants, one made of titanium (Ti6Al4V) and the other one of zirconia (ZrO2), but both of identical design, to compare their stability and micro-movements values under load. One of each type of implant (n = 42) was placed into 21 cow ribs, recording the insertion torque and the resonance frequency using a specific transducer. Subsequently, a prosthetic crown made of PMMA was screwed onto each of the implants in the sample. They were then subjected to a static compression load on the vestibular cusp of the crown. The resulting micromovements were measured. The zirconia implants obtained a higher mean of both IT and RFA when compared with those of titanium, with statistically significant differences in both cases (p = 0.0483 and p = 0.0296). However, the micromovement values when load was applied were very similar for both types, with the differences between them (p = 0.3867) not found to be statistically significant. The results show that zirconia implants have higher implant stability values than titanium implants. However, the fact that there are no differences in micromobility values implies that caution should be exercised when applying clinical protocols for zirconia based on RFA, which only has evidence for titanium.

1 October 2016 in Implant Dentistry
Verified
Journal Article
Closed access
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
MDMarkel Dieguez-Pereira
Markel Dieguez-Pereira
ÁÁÁngel Md Álvarez-Arenal
Ángel Md Álvarez-Arenal
DCDavid Chavarri-Prado
David Chavarri-Prado
ESENEKO SOLABERRIETA
ENEKO SOLABERRIETA
GSGorka Dds Santamaría-Arrieta
Gorka Dds Santamaría-Arrieta
Aim: To evaluate the resistance to axial forces of screw-retained monolithic high translucency zirconia (mHTZr) crowns compared with high translucency zirconia + feldspathic ceramic (HTZrC) crowns, low translucency zirconia + feldspathic ceramic (LTZrC) crowns, and metal-ceramic (MC) crowns, and also to observe the different fracture patterns between all groups. Methods: Twenty-four crowns were fabricated (6 of each group) and loaded until failure, using a testing machine with a 5.0-kN load cell. Results: Mean fracture results varied between 1092.7 N (LTZrC group) and 3439.7 N (mHTZr group). No statistically significant differences were found between the HTZrC, LTZrC, and MC groups. However, statistically significant differences (P < 0.05) were found between mHTZr and the other 3 groups. In the MC group, only chipping of the ceramic veneering occurred. In the mHTZr group, when fracturing occurred, it was of the whole structure. Finally, the LTZrC and HTZrC groups suffered both chipping and core fractures. Conclusion: High translucency monolithic zirconia implant–supported crowns proved to be the toughest group studied when an axial force was applied. Fracture patterns varied between different materials, chipping being the most common occurrence.

28 December 2020 in Biology
Verified
Journal Article
Open access
PDF file
DCDavid Chavarri-Prado
David Chavarri-Prado
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
ÁÁÁngel Álvarez-Arenal
Ángel Álvarez-Arenal
MDMarkel Dieguez-Pereira
Markel Dieguez-Pereira
EPEsteban Pérez-Pevida
Esteban Pérez-Pevida
AMAlejandro Estrada Martínez
Alejandro Estrada Martínez
Objectives: To determine the effect of mechanical loading of bone on the stability and histomorphometric variables of the osseointegration of dental implants using an experimental test in an animal model. Materials and Methods: A total of 4 human implants were placed in both tibiae of 10 New Zealand rabbits (n = 40). A 6-week osseointegration was considered, and the rabbits were randomly assigned to two groups: Group A (Test group) included 5 rabbits that ran on a treadmill for 20 min daily during the osseointegration period; Group B (Controls) included the other 5 that were housed conventionally. The monitored variables were related to the primary and secondary stability of the dental implants (implant stability quotient—ISQ), vertical bone growth, bone to implant contact (BIC), area of regenerated bone and the percentage of immature matrix. Results: The results of the study show a greater vertical bone growth (Group A 1.26 ± 0.48 mm, Group B 0.32 ± 0.47 mm, p < 0.001), higher ISQ values (Group A 11.25 ± 6.10 ISQ, 15.73%; Group B 5.80 ± 5.97 ISQ, 7.99%, p = 0.006) and a higher BIC (Group A 19.37%, Group B 23.60%, p = 0.0058) for implants in the test group, with statistically significant differences. A higher percentage of immature bone matrix was observed for implants in the control group (20.68 ± 9.53) than those in the test group (15.38 ± 8.84) (p = 0.108). A larger area of regenerated bone was also observed for the test implants (Group A 280.50 ± 125.40 mm2, Group B 228.00 ± 141.40 mm2), but it was not statistically significant (p = 0.121). Conclusions: The mechanical loading of bone improves the stability and the histomorphometric variables of the osseointegration of dental implants.