Purpose: To evaluate the micromobility of dental implants under occlusal loading in relation to stability measurements of resonance frequency analysis and insertion torque. Materials and Methods: The sample comprised of 24 implants inserted in 12 fresh cow ribs. Insertion torque and Osstell implant stability quotient (ISQ) measurements were recorded. An “ad hoc” acrylic premolar was made on a temporary abutment and screwed to each implant, and a force of 100 N was subsequently applied at an angle of 6 degrees. Implant micromotion was measured using a Questar microscope with a resolution of 2 μm and an image analysis program. Results: Data show a statistically significant inverse correlation between the ISQ values and implant micromotion under a load of 100 N (R2 = 0.86, P < 0.0001). The same relationship is found between insertion torque and implant micromotion, although the relationship is linear up to 34 N·cm and becomes exponential for higher values (R2 = 0.78, P < 0.0001). A direct correlation is established between insertion torque and ISQ values. Conclusion: There is an inverse relationship between both ISQ and insertion torque values and implant micromotion under a load of 100 N.
Background and Objective. Marginal bone loss around dental implants is one of the most prevalent complication, and its biomechanical impact may be critical for treatment prognosis. The objective of this study was to evaluate the influence of marginal bone loss around dental implants in the occlusal load transfer to the bone in terms of magnitude of stress and strain and distribution of such transferred stress. Methods. Three models of a single internal connection bone level‐type implant inserted into a posterior mandible bone section were constructed using a 3D finite element software: one control model without marginal bone loss and two test models, both with a circumferential peri‐implant bone defect, one with a 3 mm high defect and the other one 6 mm high. A 150 N static load was tested on the central fossa at 6° relative to the axial axis of the implant. Results. The results showed differences in the magnitude of strain and stress transferred to the bone between models, being the higher strain found in the trabecular bone around the implant with greater marginal bone loss. Stress distribution differed between models, being concentrated at the cortical bone in the control model and at the trabecular bone in the test models. Conclusion. Marginal bone loss around dental implants under occlusal loading influences the magnitude and distribution of the stress transferred and the deformation of peri‐implant bone, being higher as the bone loss increases.
1 January 2016 in Journal of Clinical and Experimental Dentistry
This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remaining 16 sites were prepared using an oversize drilling technique (overpreparation) to a working depth of 12mm. Bone density was determined using cone beam computerized tomography (CBCT). The implants were placed and primary stability was measured by two methods: insertion torque (Ncm), and RFA (implant stability quotient [ISQ]). The highest torque values were achieved by the conventional drilling technique (10mm). The ANOVA test confirmed that there was a significant correlation between torque and drilling depth (p0.05) at either measurement direction (cortical and medullar). No statistical relation between torque and ISQ values was identified, or between bone density and primary stability (p >0.05). Vertical overpreparation of the implant bed will obtain lower insertion torque values, but does not produce statistically significant differences in ISQ values. Implant stability quotient, overdrilling, primary stability, resonance frequency analysis, torque.
Aim: To evaluate the resistance to axial forces of screw-retained monolithic high translucency zirconia (mHTZr) crowns compared with high translucency zirconia + feldspathic ceramic (HTZrC) crowns, low translucency zirconia + feldspathic ceramic (LTZrC) crowns, and metal-ceramic (MC) crowns, and also to observe the different fracture patterns between all groups. Methods: Twenty-four crowns were fabricated (6 of each group) and loaded until failure, using a testing machine with a 5.0-kN load cell. Results: Mean fracture results varied between 1092.7 N (LTZrC group) and 3439.7 N (mHTZr group). No statistically significant differences were found between the HTZrC, LTZrC, and MC groups. However, statistically significant differences (P < 0.05) were found between mHTZr and the other 3 groups. In the MC group, only chipping of the ceramic veneering occurred. In the mHTZr group, when fracturing occurred, it was of the whole structure. Finally, the LTZrC and HTZrC groups suffered both chipping and core fractures. Conclusion: High translucency monolithic zirconia implant–supported crowns proved to be the toughest group studied when an axial force was applied. Fracture patterns varied between different materials, chipping being the most common occurrence.
13 December 2018 in Clinical Implant Dentistry and Related Research
Objectives: To determine the effect of mechanical loading of bone on the stability and histomorphometric variables of the osseointegration of dental implants using an experimental test in an animal model. Materials and Methods: A total of 4 human implants were placed in both tibiae of 10 New Zealand rabbits (n = 40). A 6-week osseointegration was considered, and the rabbits were randomly assigned to two groups: Group A (Test group) included 5 rabbits that ran on a treadmill for 20 min daily during the osseointegration period; Group B (Controls) included the other 5 that were housed conventionally. The monitored variables were related to the primary and secondary stability of the dental implants (implant stability quotient—ISQ), vertical bone growth, bone to implant contact (BIC), area of regenerated bone and the percentage of immature matrix. Results: The results of the study show a greater vertical bone growth (Group A 1.26 ± 0.48 mm, Group B 0.32 ± 0.47 mm, p < 0.001), higher ISQ values (Group A 11.25 ± 6.10 ISQ, 15.73%; Group B 5.80 ± 5.97 ISQ, 7.99%, p = 0.006) and a higher BIC (Group A 19.37%, Group B 23.60%, p = 0.0058) for implants in the test group, with statistically significant differences. A higher percentage of immature bone matrix was observed for implants in the control group (20.68 ± 9.53) than those in the test group (15.38 ± 8.84) (p = 0.108). A larger area of regenerated bone was also observed for the test implants (Group A 280.50 ± 125.40 mm2, Group B 228.00 ± 141.40 mm2), but it was not statistically significant (p = 0.121). Conclusions: The mechanical loading of bone improves the stability and the histomorphometric variables of the osseointegration of dental implants.