Pavel Dobeš

Dr. Pavel Dobeš

Technical University of Ostrava, Ostrava, Moravskoslezský Kraj, Czech Republic
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2020 in Materials
Verified
Journal Article
Open access
PDF file
Antonín LokajAntonín Lokaj
Antonín Lokaj
Pavel DobešPavel Dobeš
Pavel Dobeš
Oldrich SuchardaOldrich Sucharda
Oldrich Sucharda
This article presents the results of static tests on bolted connections in squared and round timber with inserted steel plates. The experiment evaluates structural timber connections with different distances between the fastener and the loaded end at different moisture contents. Specimens were loaded by tension parallel to the grain and load–deformation diagrams were recorded. Fifty-six specimens with three different distances between the fastener and the loaded end, at different moisture contents, were tested. The results were statistically evaluated using regression analysis, complemented with load–deformation curves, and compared with calculations according to the valid standard for design of timber structures. A decrease in the evaluated load-carrying capacity with increasing moisture content was confirmed experimentally. A slight increase in the evaluated load-carrying capacity with increasing fastener distance from the loaded end was found.

11 January 2023 in Buildings
Verified
Journal Article
Open access
PDF file
Pavel DobešPavel Dobeš
Pavel Dobeš
Antonín LokajAntonín Lokaj
Antonín Lokaj
Kristýna VavrušováKristýna Vavrušová
Kristýna Vavrušová
Timber structures are currently more important for solving tasks in construction practice. For this reason, there is an opportunity for research in the area of physical tests and numerical models. This paper deals with the determination and comparison of the deformation properties of cross-laminated timber (CLT) panels based on laboratory tests, analytical calculation and numerical modeling. CLT panels are structural building components consisting of cross-oriented solid timber layers. Three types of panels with different geometry and number of layers (three, five and seven) were experimentally tested using a four-point bending test, where load–deformation curves were recorded. The results of the experimental testing of the three-layer panels were subsequently compared with a numerical model in SCIA Engineer, a numerical model in ANSYS Workbench and an analytical calculation. The research shows a good agreement in bending behavior between the laboratory tests, the analytical calculation according to the standard and two different approaches in numerical analysis.

7 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
Pavel DobešPavel Dobeš
Pavel Dobeš
Antonín LokajAntonín Lokaj
Antonín Lokaj
DMDavid Mikolasek
David Mikolasek
Nowadays, the use of timber as a building material is gaining more prominence. When designing timber structures, it is necessary to pay increased attention to the design of their connections. The commonly used connections are dowel-type connections, which are often used in combination with steel plates slotted into cut-outs in timber members. The presented paper deals with the behavior of double-shear bolted connections of squared timber and round timber with slotted-in steel plates. Several variants of connections with different distances between the fastener and the loaded end were selected for the experimental testing. A total of six types of test specimens were made from spruce timber, for which their selected physical properties were determined and evaluated before the experimental testing. Test specimens of bolted connections were first tested in tension parallel to the grain until failure under quasi-static loading. The connections were broken by splitting. Ductile failure preceded brittle failure. The actual load-carrying capacities were lowest for the lowest end distance. The load-carrying capacities for the middle and the longest end distances were comparable. The results of the experiments were then used for comparison with calculation procedures according to the standard for the design of timber structures and with calculations according to the theory of linear elastic fracture mechanics. The experiments and the analytical models were supported by a simple numerical analysis based on the finite element method.

30 April 2022 in Buildings
Verified
Journal Article
Open access
PDF file
MJMarek Johanides
Marek Johanides
Antonín LokajAntonín Lokaj
Antonín Lokaj
DMDavid Mikolasek
David Mikolasek
Petr MynarcikPetr Mynarcik
Petr Mynarcik
Pavel DobešPavel Dobeš
Pavel Dobeš
Oldrich SuchardaOldrich Sucharda
Oldrich Sucharda
The present study deals with the innovation and the possibilities of improving the design solution of a frame connection for two selected types of fasteners. All specimens were made of glued laminated timber. Dowel-type mechanical fasteners, a combination of bolts and dowels, and full-threaded screws were used for the connection. The main goal of this research was to replace the typical solution (common dowel-type fasteners) with a more modern, faster, and easier solution in order to improve the load-carrying capacity, ductility, and deformation capacity of this type of frame connection. This article also aimed to provide a detailed evaluation of the mechanical properties of the used glued laminated timber and fasteners in order to comprehensively evaluate the research task. For the design solution, a frame connection created from a system of two struts and a partition was chosen as the basis of the experimental program. Dowel-type mechanical fasteners, as well as combinations of bolts and dowels, were used for the connection; however, in addition to these standardly used mechanical fasteners, full-threaded screws were used. The article describes the use of static destructive testing to determine the ductility of the connection, considering different variations in the strengthening of the individual segments of the mentioned connection means. In the first variation, the individual components of the frame were not reinforced in any way. In the second, the crossbar was reinforced with two full-threaded bolts. In the third, the webs and the crossbar were reinforced with two full-threaded bolts. In the article, these ductility values were compared with each other and the procedure was set by the currently valid standard.

17 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
MJMarek Johanides
Marek Johanides
Antonín LokajAntonín Lokaj
Antonín Lokaj
Pavel DobešPavel Dobeš
Pavel Dobeš
DMDavid Mikolasek
David Mikolasek
The paper deals with the analysis of the load-carrying capacity of a timber semi-rigid connection created from a system of two stands and a rung. The connection was made from glued laminated timber with metal mechanical dowel-type fasteners. Not only a common combination of bolts and dowels, but also fully threaded screws were used for the connection. The aim of the research and its motivation was to replace these commonly used fasteners with more modern ones, to shorten and simplify the assembly time, and to improve the load-carrying capacity of this type of connection. Each of these two types of connections was loaded statically, with a slow increase in force until failure. The paper presents results of the experimental testing. Three specimens were made and tested for each type of the connection. Experimental results were subsequently compared with numerical models. The achieved results were also compared with the assumption according to the currently valid standard. The results indicate that a connection using fully threaded screws provides a better load-carrying capacity.

16 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
MJMarek Johanides
Marek Johanides
Antonín LokajAntonín Lokaj
Antonín Lokaj
Pavel DobešPavel Dobeš
Pavel Dobeš
DMDavid Mikolasek
David Mikolasek
The paper deals with the analysis of the rotational stiffness of a semirigid connection created from a system of two stands and a rung. The connection was made from glued laminated timber with metal mechanical dowel-type fasteners. Not only a common combination of bolts and dowels but also fully threaded screws were used for the connection. The aim of the research and its motivation was to replace commonly used fasteners with more modern ones, to shorten and simplify the assembly time, and to improve the load-carrying capacity of this type of connection. Each of these two types of connection was loaded to the level of 60%, 80%, and 100% of the ultimate limit state value. Subsequently, the rotational stiffness was determined for each load level after five loading and unloading cycles. This paper presents the results and comparison of the experimental testing and the numerical modeling. The obtained results were also compared with the assumption according to the currently valid standard.