Marek Johanides

Mr. Marek Johanides

VSB Technical University of Ostrava, Faculty of Civil Engineering, Department of Structures
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
MJMarek Johanides
Marek Johanides
LKLenka Kubíncová
Lenka Kubíncová
DMDavid Mikolasek
David Mikolasek
Antonín LokajAntonín Lokaj
Antonín Lokaj
Oldrich SuchardaOldrich Sucharda
Oldrich Sucharda
Petr MynarcikPetr Mynarcik
Petr Mynarcik
Initially, timber was considered only as an easily accessible and processable material in nature; however, its excellent properties have since become better understood. During the discovery of new building materials and thanks to new technological development processes, industrial processing technologies and gradually drastically decreasing forest areas, wood has become an increasingly neglected material. Load-bearing structures are made mostly of reinforced concrete or steel elements. However, ecological changes, the obvious problems associated with environmental pollution and climate change, are drawing increasing attention to the importance of environmental awareness. These factors are attracting increased attention to wood as a building material. The increased demand for timber as a building material offers the possibility of improving its mechanical and physical properties, and so new wood-based composite materials or new joints of timber structures are being developed to ensure a better load capacity and stiffness of the structure. Therefore, this article deals with the improvement of the frame connection of the timber frame column and a diaphragm beam using mechanical fasteners. In common practice, bolts or a combination of bolts and pins are used for this type of connection. The subject of the research and its motivation was to replace these commonly used fasteners with more modern ones to shorten and simplify the assembly time and to improve the load capacity and rigidity of this type of frame connection.

3 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
MJMarek Johanides
Marek Johanides
DMDavid Mikolasek
David Mikolasek
Antonín LokajAntonín Lokaj
Antonín Lokaj
Petr MynarcikPetr Mynarcik
Petr Mynarcik
ZMZuzana Marcalikova
Zuzana Marcalikova
Oldrich SuchardaOldrich Sucharda
Oldrich Sucharda
With the development of wooden structures and buildings, there is a need to research physical and numerical tests of wood-based structures. The presented research is focused on construction and computational approaches for new types of joints to use in wooden structures, particularly glued lamella elements made of wood and wood-based composites. This article focuses on improving the frame connection of a wooden post and a beam with the use of fasteners to ensure better load-bearing capacity and stiffness of the structure. In common practice, bolts or a combination of bolts and pins are used for this type of connection. The aim is to replace these commonly used fasteners with modern ones, namely full thread screws. The aim is also to shorten and simplify the assembly time in order to improve the load-bearing capacity and rigidity of this type of frame connection. Two variations of the experimental test were tested in this research. The first contained bolts and pins as connecting means and the second contained the connecting means of a full threaded screw. Each experiment contained a total of two tests. For a detailed study of the problem, we used a 2D or 3D computational model that models individual components, including fasteners.

30 April 2022 in Buildings
Verified
Journal Article
Open access
PDF file
MJMarek Johanides
Marek Johanides
Antonín LokajAntonín Lokaj
Antonín Lokaj
DMDavid Mikolasek
David Mikolasek
Petr MynarcikPetr Mynarcik
Petr Mynarcik
Pavel DobešPavel Dobeš
Pavel Dobeš
Oldrich SuchardaOldrich Sucharda
Oldrich Sucharda
The present study deals with the innovation and the possibilities of improving the design solution of a frame connection for two selected types of fasteners. All specimens were made of glued laminated timber. Dowel-type mechanical fasteners, a combination of bolts and dowels, and full-threaded screws were used for the connection. The main goal of this research was to replace the typical solution (common dowel-type fasteners) with a more modern, faster, and easier solution in order to improve the load-carrying capacity, ductility, and deformation capacity of this type of frame connection. This article also aimed to provide a detailed evaluation of the mechanical properties of the used glued laminated timber and fasteners in order to comprehensively evaluate the research task. For the design solution, a frame connection created from a system of two struts and a partition was chosen as the basis of the experimental program. Dowel-type mechanical fasteners, as well as combinations of bolts and dowels, were used for the connection; however, in addition to these standardly used mechanical fasteners, full-threaded screws were used. The article describes the use of static destructive testing to determine the ductility of the connection, considering different variations in the strengthening of the individual segments of the mentioned connection means. In the first variation, the individual components of the frame were not reinforced in any way. In the second, the crossbar was reinforced with two full-threaded bolts. In the third, the webs and the crossbar were reinforced with two full-threaded bolts. In the article, these ductility values were compared with each other and the procedure was set by the currently valid standard.

17 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
MJMarek Johanides
Marek Johanides
Antonín LokajAntonín Lokaj
Antonín Lokaj
Pavel DobešPavel Dobeš
Pavel Dobeš
DMDavid Mikolasek
David Mikolasek
The paper deals with the analysis of the load-carrying capacity of a timber semi-rigid connection created from a system of two stands and a rung. The connection was made from glued laminated timber with metal mechanical dowel-type fasteners. Not only a common combination of bolts and dowels, but also fully threaded screws were used for the connection. The aim of the research and its motivation was to replace these commonly used fasteners with more modern ones, to shorten and simplify the assembly time, and to improve the load-carrying capacity of this type of connection. Each of these two types of connections was loaded statically, with a slow increase in force until failure. The paper presents results of the experimental testing. Three specimens were made and tested for each type of the connection. Experimental results were subsequently compared with numerical models. The achieved results were also compared with the assumption according to the currently valid standard. The results indicate that a connection using fully threaded screws provides a better load-carrying capacity.

16 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
MJMarek Johanides
Marek Johanides
Antonín LokajAntonín Lokaj
Antonín Lokaj
Pavel DobešPavel Dobeš
Pavel Dobeš
DMDavid Mikolasek
David Mikolasek
The paper deals with the analysis of the rotational stiffness of a semirigid connection created from a system of two stands and a rung. The connection was made from glued laminated timber with metal mechanical dowel-type fasteners. Not only a common combination of bolts and dowels but also fully threaded screws were used for the connection. The aim of the research and its motivation was to replace commonly used fasteners with more modern ones, to shorten and simplify the assembly time, and to improve the load-carrying capacity of this type of connection. Each of these two types of connection was loaded to the level of 60%, 80%, and 100% of the ultimate limit state value. Subsequently, the rotational stiffness was determined for each load level after five loading and unloading cycles. This paper presents the results and comparison of the experimental testing and the numerical modeling. The obtained results were also compared with the assumption according to the currently valid standard.

1 January 2023 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
DMDavid Mikolasek
David Mikolasek
ZMZuzana Marcalikova
Zuzana Marcalikova
MJMarek Johanides
Marek Johanides
Antonín LokajAntonín Lokaj
Antonín Lokaj
The research area of timber and timber structures is becoming more and more topical with regard to the sustainable development of buildings. Current research directions also include structural optimization of frame corners. Possible approaches include the use of experimental tests, which are very valuable and time-consuming when it is necessary to use often special preparations. However, before carrying out the experiments, it is advisable to verify the proposed experiment, for example, using numerical modelling. It is appropriate, for example, to use a stability calculation that verified the global and local stability of the structure. However, for a sufficient explanatory value, it is necessary to use advanced 3D computer models, which cover a similar level of structural solution. For these models, it is also necessary to take into account the connecting means and test fixtures. The presented contribution focuses on the mentioned area, which is focused on the experiment carried out, where the of individual parts to the stiffness of the system is verified using numerical modelling and the stability of the entire structure is also verified. The created calculation model respects individual parts in detail up to the level of fasteners and test preparations.