Initially, timber was considered only as an easily accessible and processable material in nature; however, its excellent properties have since become better understood. During the discovery of new building materials and thanks to new technological development processes, industrial processing technologies and gradually drastically decreasing forest areas, wood has become an increasingly neglected material. Load-bearing structures are made mostly of reinforced concrete or steel elements. However, ecological changes, the obvious problems associated with environmental pollution and climate change, are drawing increasing attention to the importance of environmental awareness. These factors are attracting increased attention to wood as a building material. The increased demand for timber as a building material offers the possibility of improving its mechanical and physical properties, and so new wood-based composite materials or new joints of timber structures are being developed to ensure a better load capacity and stiffness of the structure. Therefore, this article deals with the improvement of the frame connection of the timber frame column and a diaphragm beam using mechanical fasteners. In common practice, bolts or a combination of bolts and pins are used for this type of connection. The subject of the research and its motivation was to replace these commonly used fasteners with more modern ones to shorten and simplify the assembly time and to improve the load capacity and rigidity of this type of frame connection.
With the development of wooden structures and buildings, there is a need to research physical and numerical tests of wood-based structures. The presented research is focused on construction and computational approaches for new types of joints to use in wooden structures, particularly glued lamella elements made of wood and wood-based composites. This article focuses on improving the frame connection of a wooden post and a beam with the use of fasteners to ensure better load-bearing capacity and stiffness of the structure. In common practice, bolts or a combination of bolts and pins are used for this type of connection. The aim is to replace these commonly used fasteners with modern ones, namely full thread screws. The aim is also to shorten and simplify the assembly time in order to improve the load-bearing capacity and rigidity of this type of frame connection. Two variations of the experimental test were tested in this research. The first contained bolts and pins as connecting means and the second contained the connecting means of a full threaded screw. Each experiment contained a total of two tests. For a detailed study of the problem, we used a 2D or 3D computational model that models individual components, including fasteners.
The present study deals with the innovation and the possibilities of improving the design solution of a frame connection for two selected types of fasteners. All specimens were made of glued laminated timber. Dowel-type mechanical fasteners, a combination of bolts and dowels, and full-threaded screws were used for the connection. The main goal of this research was to replace the typical solution (common dowel-type fasteners) with a more modern, faster, and easier solution in order to improve the load-carrying capacity, ductility, and deformation capacity of this type of frame connection. This article also aimed to provide a detailed evaluation of the mechanical properties of the used glued laminated timber and fasteners in order to comprehensively evaluate the research task. For the design solution, a frame connection created from a system of two struts and a partition was chosen as the basis of the experimental program. Dowel-type mechanical fasteners, as well as combinations of bolts and dowels, were used for the connection; however, in addition to these standardly used mechanical fasteners, full-threaded screws were used. The article describes the use of static destructive testing to determine the ductility of the connection, considering different variations in the strengthening of the individual segments of the mentioned connection means. In the first variation, the individual components of the frame were not reinforced in any way. In the second, the crossbar was reinforced with two full-threaded bolts. In the third, the webs and the crossbar were reinforced with two full-threaded bolts. In the article, these ductility values were compared with each other and the procedure was set by the currently valid standard.
One of the options for rehabilitating existing masonry buildings is a post-tensioning of masonry. The deformation properties of the masonry in the direction parallel to bed joints are essential for the design of a suitable value of the applied force. However, these values are usually not available or are defined only roughly. The aim of this study was to determine, as accurately as possible, the deformation characteristics of the masonry in the direction parallel to the bed joints. Experimental measuring of masonry samples was carried out in laboratory facilities designed specifically for testing the triaxial state of stress of the masonry. The obtained deformations were used to determine the modulus of elasticity of the masonry in the direction of bed joints. Within these experimental tests, laboratory measuring of mechanical masonry properties was carried out, and deformation characteristics were defined on the basis of calculations. The strengths of masonry units and mortar were tested in the laboratory and, according to the tests results, the modulus of elasticity in the direction perpendicular to bed joints was determined. The modulus of elasticity in the direction parallel to bed joints was verified through a simple numerical model. The calculated deformations were compared with the measured values. On the basis of the determination of the deformation characteristics of masonry in the direction of bed joints, the ratios of the modulus of elasticity in the direction perpendicular and parallel to bed joints were concluded.
The issue of insufficient reliability and, in some cases, the failure of post - tensioned bridge structures, footbridges, and roof trusses, particularly in industrial halls, is one of the current and serious problems of the construction industry in the Czech Republic. The most well - known failures of these structures include the collapse of the Morandi Bridge near Genoa, Italy, in August 2018, and the collapse of the Troja footbridge in Prague in December 2017. Less known are the failures of post - tensioned truss roof structures that occurred in the Czech Republic and Slovakia. Especially in the Czech Republic, there were failures in Tachov (2010 and 2018), Sluknov (December 2023), and Karlovy Vary (March 2024). A common feature of all these failures was the corrosion of the prestressing reinforcement in inadequately grouted cable ducts. Roof structures of this type have been used in more than 100 buildings that are still in operation in the Czech Republic. In response to this situation, the company Rada Building s.r.o., in cooperation with academic institutions, developed a method to reinforce trusses threatened by corrosion using an external steel structure. The company carries out the reinforcement work during normal operation in the hall below the trusses. Research on post - tensioned truss structures and the possibilities of their static securing is being conducted in cooperation with the Faculty of Civil Engineering at VSB – Technical University of Ostrava, the Faculty of Art and Architecture at the Technical University of Liberec, and the company Rada Building, s.r.o. The ambition of the research is to analyze the condition of as many trusses as possible embedded in buildings in the Czech Republic and Slovakia using building structure diagnostic methods and to evaluate these surveys. Furthermore, the research aims to verify the actual behavior of such structures through tests on real trusses taken from demolished buildings. VSB – TU Ostrava has several trusses available, and load tests are currently being carried out on them. An important and final part of the research is to find the optimal diagnostic method that would improve the ability to predict the risk of roof failures in operational buildings and to optimize the methods for securing these structures to ensure full static reliability with the lowest possible costs and minimal impact on the building.