Minhye Chang

Minhye Chang

Auto-generated profile, based on publicly available information

Minhye Chang

Korea Electrotechnology Research Institute Ansan‐si Gyeonggi‐do Republic of Korea

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
KSKiyoung Shin
Kiyoung Shin
RMRyan McConville
Ryan McConville
OMOussama Metatla
Oussama Metatla
MCMinhye Chang
Minhye Chang
CHChiyoung Han
Chiyoung Han
Anne RoudautAnne Roudaut
Anne Roudaut
One of the major challenges for blind and visually impaired (BVI) people is traveling safely to cross intersections on foot. Many countries are now generating audible signals at crossings for visually impaired people to help with this problem. However, these accessible pedestrian signals can result in confusion for visually impaired people as they do not know which signal must be interpreted for traveling multiple crosses in complex road architecture. To solve this problem, we propose an assistive system called CAS (Crossing Assistance System) which extends the principle of the BLE (Bluetooth Low Energy) RSSI (Received Signal Strength Indicator) signal for outdoor and indoor location tracking and overcomes the intrinsic limitation of outdoor noise to enable us to locate the user effectively. We installed the system on a real-world intersection and collected a set of data for demonstrating the feasibility of outdoor RSSI tracking in a series of two studies. In the first study, our goal was to show the feasibility of using outdoor RSSI on the localization of four zones. We used a k-nearest neighbors (kNN) method and showed it led to 99.8% accuracy. In the second study, we extended our work to a more complex setup with nine zones, evaluated both the kNN and an additional method, a Support Vector Machine (SVM) with various RSSI features for classification. We found that the SVM performed best using the RSSI average, standard deviation, median, interquartile range (IQR) of the RSSI over a 5 s window. The best method can localize people with 97.7% accuracy. We conclude this paper by discussing how our system can impact navigation for BVI users in outdoor and indoor setups and what are the implications of these findings on the design of both wearable and traffic assistive technology for blind pedestrian navigation.

16 June 2019 in Computational Intelligence and Neuroscience
Verified
Journal Article
Open access
PDF file
HBHyun Jae Baek
Hyun Jae Baek
MCMin Hye Chang
Min Hye Chang
JHJeong Heo
Jeong Heo
KPKwang Suk Park
Kwang Suk Park
Brain-computer interfaces (BCIs) aim to enable people to interact with the external world through an alternative, nonmuscular communication channel that uses brain signal responses to complete specific cognitive tasks. BCIs have been growing rapidly during the past few years, with most of the BCI research focusing on system performance, such as improving accuracy or information transfer rate. Despite these advances, BCI research and development is still in its infancy and requires further consideration to significantly affect human experience in most real-world environments. This paper reviews the most recent studies and findings about ergonomic issues in BCIs. We review dry electrodes that can be used to detect brain signals with high enough quality to apply in BCIs and discuss their advantages, disadvantages, and performance. Also, an overview is provided of the wide range of recent efforts to create new interface designs that do not induce fatigue or discomfort during everyday, long-term use. The basic principles of each technique are described, along with examples of current applications in BCI research. Finally, we demonstrate a user-friendly interface paradigm that uses dry capacitive electrodes that do not require any preparation procedure for EEG signal acquisition. We explore the capacitively measured steady-state visual evoked potential (SSVEP) response to an amplitude-modulated visual stimulus and the auditory steady-state response (ASSR) to an auditory stimulus modulated by familiar natural sounds to verify their availability for BCI. We report the first results of an online demonstration that adopted this ergonomic approach to evaluating BCI applications. We expect BCI to become a routine clinical, assistive, and commercial tool through advanced EEG monitoring techniques and innovative interface designs.

16 October 2024 in IEEE Access
Verified
Journal Article
Open access
MCMinhye Chang
Minhye Chang
WLWonju Lee
Wonju Lee
KJKye Young Jeong
Kye Young Jeong
JKJun Wan Kim
Jun Wan Kim
CJChang Hee Jung
Chang Hee Jung
Oxygen saturation is a crucial metric used in various medical contexts, indicating the concentration of oxygen in the blood. Recently, hyperspectral imaging-based oximetry techniques have been proposed for broad applications of two-dimensional information without sensor contact. However, these methods suffer from high computational complexity and inefficiency due to large hypercubes. In this study, we investigate an efficient tissue oxygen saturation (StO2) mapping from hyperspectral image using a generative adversarial network (GAN). The model was trained on hyperspectral images acquired from 40 healthy individuals. The Non-dominated Sorting Genetic Algorithm II (NSGA-II) was then used to identify the optimal combination of hyperspectral bands to reduce the number of bands required for computation while maintaining performance. The selected optimal band combinations included both visible and near-infrared (NIR) bands. The GAN-based model with the ten-band combination estimated StO2 effectively, achieving a root mean squared error (RMSE) of 0.1169 ± 0.0350. Finally, the model trained on healthy subjects’ data was applied to the palm and sole images of 20 patients with type 2 diabetes mellitus (DM) to validate its performance. The performance on the patient data was comparable to that obtained from healthy individuals, with the best performance achieved using the ten-band combination (RMSE=0.1077 ± 0.0341). In conclusion, the developed efficient hyperspectral image-based oxygenation mapping method demonstrated robust performance for patients with type 2 DM as well as healthy subjects.

19 March 2025 in IEEE Access
Verified
Journal Article
Open access
HBHaejun Bae
Haejun Bae
DKDong-Goo Kang
Dong-Goo Kang
MCMinhye Chang
Minhye Chang
KJKye Young Jeong
Kye Young Jeong
Byung SongByung Song
Byung Song
Semantic segmentation in the Long-Wave Infrared (LWIR) domain is critical for a wide range of applications including emergency response, industrial safety monitoring, and public building security. However, LWIR images often suffer from inherent pattern noise and ambiguous object boundaries that hinder accurate segmentation. To address these challenges, this study presents a novel real-time semantic segmentation framework specifically designed for LWIR images. The framework incorporates a Stripe noise Denoising Module (SDM) and a Boundary Enhancement Module (BEM), which leverage frequency-domain filtering and learnable weights to adaptively process noisy input data and improve boundary prediction. In addition, a Multi-Stream Fusion Module (MSFM) integrates multi-scale semantic features with boundary information, thereby enhancing segmentation accuracy across diverse object scales. The proposed method demonstrates state-of-the-art performance in both accuracy and efficiency on multiple datasets, including KERInha and SODA. Extensive qualitative and quantitative evaluations further validate its robustness, particularly in scenarios where RGB imagery is unavailable. By eliminating the need for supplementary information such as depth data, this approach facilitates precise indoor and outdoor segmentation tasks with lightweight computation, making it highly suitable for real-world applications.

22 December 2025 in IEEE Access
Verified
Journal Article
Open access
WLWonju Lee
Wonju Lee
MCMinhye Chang
Minhye Chang
SKSoojung Kim
Soojung Kim
BLByungsuk Lee
Byungsuk Lee
CJChang Hee Jung
Chang Hee Jung
KKKyujung Kim
Kyujung Kim
We employed hyperspectral polarization imaging and short-wave infrared (SWIR) spectral imaging to characterize dorsal hand skin in young healthy adults and older individuals with type 2 diabetes mellitus (T2DM). Polarization contrast maps (PCM) quantified tissue microstructure, while hydration contrast maps (HCM) assessed water content. Both metrics were analyzed in terms of mean values and spatial complexity using the coefficient of variation and Shannon entropy. Compared to healthy controls, diabetic skin exhibited significantly elevated mean PCM values and increased spatial heterogeneity in both PCM and HCM domains. These findings are consistent with spatially irregular tissue remodeling rather than uniform structural changes. Correlation analysis revealed a negative relationship between PCM and hydration in healthy skin that was absent in diabetic tissue, suggesting a decoupling of structural and hydration regulation in metabolically compromised skin. This dual-domain framework, which integrates mean and spatially resolved optical metrics spanning both structural and functional dimensions, may provide non-invasive optical signatures indicative of skin remodeling associated with aging and diabetes. Such signatures could enable objective disease monitoring and support the evaluation of therapeutic responses.

10 December 1991 in ChemInform
Verified
Journal Article
Closed access
PDF file
SSS. C. Shim
S. C. Shim
JHJ. T. Hwang
J. T. Hwang
HKH.‐Y. Kang
H.‐Y. Kang
MCM. H. Chang
M. H. Chang