Carmen María Díaz-Castro

Dr. Carmen María Díaz-Castro

Faculty of dentistry, University of Seville
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2018 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
PLPaula López-Jarana
Paula López-Jarana
CDCarmen María Díaz-Castro
Carmen María Díaz-Castro
AFA. Falcão
A. Falcão
CFCarlos Falcão
Carlos Falcão
José Vicente Ríos-SantosJosé Vicente Ríos-Santos
José Vicente Ríos-Santos
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
The objective of this paper is to anatomically describe the bone morphology in the maxillary and mandibular tooth areas, which might help in planning post-extraction implants. CBCT images (Planmeca ProMax 3D) of 403 teeth (208 upper teeth and 195 lower teeth) were obtained from 49 patients referred to the Dental School of Seville from January to December 2014. The thickness of the facial wall was measured at the crest, point A, 4 mm below, point B, and at the apex, point C. The second parameter was the angle formed between the dental axis and the axis of the basal bone. A total of 403 teeth were measured. In the maxilla, 89.4% of incisors, 93.94% of canines, 78% of premolars and 70.5% of molars had a buccal bone wall thickness less than the ideal 2 mm. In the mandible, 73.5% of incisors, 49% of canines, 64% of premolars and 53% of molars had < 1 mm buccal bone thickness as measured at point B. The mean angulation in the maxilla was 11.67 ± 6.37° for incisors, 16.88 ± 7.93° for canines, 13.93 ± 8.6° for premolars, and 9.89 ± 4.8° for molars. In the mandible, the mean values were 10.63 ± 8.76° for incisors, 10.98 ± 7.36° for canines, 10.54 ± 5.82° for premolars and 16.19 ± 11.22° for molars. The high incidence of a buccal wall thickness of less than 2 mm in over 80% of the assessed sites indicates the need for additional regeneration procedures, and several locations may also require custom abutments to solve the angulation problems for screw-retained crowns.

Paulo António RibeiroPaulo António Ribeiro
Paulo António Ribeiro
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
CDCarmen María Díaz-Castro
Carmen María Díaz-Castro
José Vicente Ríos-SantosJosé Vicente Ríos-Santos
José Vicente Ríos-Santos
RPRoberto Padrós
Roberto Padrós
CFCarlos Falcão
Carlos Falcão
Purpose: The aim of this study was to compare the accuracy of digital dental impressions with the accuracy of impressions obtained via conventional techniques. Methods: Two different master models were created, one with parallel implants (model 1) and the other with non-parallel implants (model 2). These reference master models included 4 Klockner KL RP implants (Klockner Implant System SA, Barcelona, Spain), which were juxta-placed and equidistant in the intermentoneal region. In model 1 the implants were placed parallel to each other, whereas in model 2 the implants were placed such that there was a divergence angle of 15° between the more distal implants, and a convergence angle of 15° between the two central implants. A total of four types of impressions were obtained from model 1 (four groups, n = 10 each), including closed tray impressions with replacement abutments; open tray impression groups for dragging copings, without splinting; open tray impressions for ferrules; and impressions obtained using the 3MTM True Definition Scanner system. For model 2 three groups were created (three groups, n = 10 each), including closed tray impressions with replacement abutments; open tray impression for dragging copings, without splinting; and impressions obtained using the 3MTM True Definition Scanner system. The master models and the models obtained using conventional methods were digitalized in order to compare them via an extraoral high-resolution scanner (Imetric IScan D104i, Porretruy, Switzerland). The STL (Stereo Lithography (format for transferring 3 dimensional shape information)) digital values were loaded into reverse-engineering software and superimposed with their respective STL master models in order to evaluate deviations in three dimensions. We then analyzed the squares of the deviations in the three axes and evaluated the median and the sum of the deviation square. Statistical analysis was performed using the IBM Corp. Released 2016. IBM SPSS Statistics for Windows, Version 24.0. Armonk, NY: IBM Corp. The normality of the distributions was analyzed according to a Kolmogorov-Smirnov test. The median comparison was performed using the differences between the medians, analyzed using non-parametric Kruskal-Wallis and Mann-Whitney tests with a significance level of p < 0.05. Results: For model 1, the deviations of the digital impressions were smaller than those associated with the conventional techniques. The sum value in group D was 1,068,292, which was significantly lower than those of groups A, B, and C, which were shown to be 2,114,342, 2,165,491, and 1,265,918, respectively. This improvement was not observed when using model 2, however, where the conventional techniques yielded similar results. Group F simultaneously presented the lowest total square sum of the three deviations (1,257,835), indicating a significantly higher accuracy for this group in model 2, while the sum values were 1,660,975 and 1,489,328 for groups E and G, respectively. Conclusion: Digital impressions of full-arch models were able to achieve the accuracy of conventional impressions in an in vitro model. Nevertheless, further in vivo studies are needed to validate these in vitro results.

15 August 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
Paulo António RibeiroPaulo António Ribeiro
Paulo António Ribeiro
CDCarmen María Díaz-Castro
Carmen María Díaz-Castro
BRBlanca Ríos-Carrasco
Blanca Ríos-Carrasco
José Vicente Ríos-SantosJosé Vicente Ríos-Santos
José Vicente Ríos-Santos
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
Photogrammetry (PG) appeared as an alternative for multiple implant impressions. Stereo-photogrammetry is a more sophisticated alternative to PG, which estimates the 3D coordinates of the points of an object, making the process quicker and more precise. A search in PubMed MEDLINE, PMC, and Google Scholar was conducted to find systematic reviews published in the last 10 years. The PICdental® camera (IDITEC NORTH WEST, SL; Torrelodones, Spain) is a stereocamera that records implant positions in the mouth by means of photogrammetry with the objective of registering and obtaining a viable, reliable, and direct digital impression of the positions of the multiple implants. The use of photogrammetry via PiCdental® camera as an alternative to digital impression for multiple implants is an easy and trustworthy technique that permits an adequate fit without prosthetic complications.

MAMatteo Albertini
Matteo Albertini
FHFederico Herrero-Climent
Federico Herrero-Climent
CDCarmen María Díaz-Castro
Carmen María Díaz-Castro
JNJosé Nart
José Nart
AFAna Fernandez-Palacin
Ana Fernandez-Palacin
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
Background: Implant dentistry has evolved over time, resulting in better treatment outcomes for both patients and clinicians. The aim of this trial was to test whether the immediate loading of implants with a platform-switching design influences the marginal bone level, compared to four-week loading, after one year of follow-up. Moreover, a comparison of clinical data regarding implant survival, implant stability, and patient-reported outcome measures (PROMs) was conducted. Methods: Klockner® VEGA® implants with a ContacTi® surface were placed in partially edentulous patients in the posterior areas. Group A received an immediately loaded prosthesis (one week) and Group B received an early-loaded prosthesis (four weeks). All abutments were placed at the time of surgery. Radiographic and clinical data were recorded. Results: Twenty-one patients were treated (35 implants). No implants were lost during the study. The final marginal bone level did not show differences between groups. The bone loss at 12 months at the implant level was 0.00 mm for both groups (median). The final implant quotient stability (ISQ) values did not differ between groups (median 73 and 70.25), nor did the other clinical parameters or PROMs. Conclusions: The results suggest that neither of the loading protocols with the implants used influenced the marginal bone level—not the osseointegration rate, clinical conditions, or PROMs.

PLPaula López-Jarana
Paula López-Jarana
CDCarmen María Díaz-Castro
Carmen María Díaz-Castro
AFArtur Falcão
Artur Falcão
BRBlanca Ríos-Carrasco
Blanca Ríos-Carrasco
AFAna Fernandez-Palacin
Ana Fernandez-Palacin
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
In order to apply the “one-abutment–one-time” concept, we evaluated the possibility of measuring resonance frequency analysis (RFA) on the abutment. This trial aimed to compare the Implant Stability Quotient (ISQ) values obtained by the PenguinRFA when screwing the transducer onto the implant or onto abutments with different heights and angulations. Eighty implants (VEGA®, Klockner Implant System, SOADCO, Les Escaldes, Andorra) were inserted into fresh bovine ribs. The groups were composed of 20 implants, 12 mm in length, with two diameters (3.5 and 4 mm). Five different abutments for screwed retained restorations (Permanent®) were placed as follows: straight with 1, 2, and 3 mm heights, and angulated at 18° with 2 and 3 mm heights. The mean value of the ISQ measured directly on the implant was 75.72 ± 4.37. The mean value of the ISQ registered over straight abutments was 79.5 ± 8.50, 76.12 ± 6.63, and 71.42 ± 6.86 for 1, 2, and 3 mm height abutments. The mean ISQ over angled abutments of 2 and 3 mm heights were 68.74 ± 4.68 and 64.51 ± 4.53 respectively. The present study demonstrates that, when the ISQ is registered over the straight abutments of 2 and 3 mm heights, the values decrease, and values are lower for angled, 3 mm height abutments.

CDCarmen María Díaz-Castro
Carmen María Díaz-Castro
PCPedro Lázaro Calvo
Pedro Lázaro Calvo
Javier GilJavier Gil
Javier Gil
AFAna Fernandez-Palacin
Ana Fernandez-Palacin
José Vicente Ríos-SantosJosé Vicente Ríos-Santos
José Vicente Ríos-Santos
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
Numerous randomised controlled multicentric studies have investigated various responses to different treatment modalities with dental implants. These studies do not always show the results of daily practice as they are performed under controlled and strict clinical conditions. This multicentric, non-interventionist trial aimed to document the behaviour of implants when used in daily dental practice, without inclusion or exclusion criteria. One hundred and ninety-six screw-shaped, tissue-level implants were placed, and each clinician decided which implant, surgical loading and prosthetic protocol to use. At surgery, data related to the implants were recorded. Additionally, the crestal bone level changes were evaluated for up to two years of follow-up. Two implants were lost before they were loaded. The success rate was 98.31%, and the survival rate was 98.79%. The implant stability quotient (ISQ) at surgery was 68.61 ± 10.35 and at 2 years was 74.39 ± 9.64. The crestal–shoulder distances were 1.25 ± 1.09 mm and 1.68 ± 1.07 mm in the mesial and distal aspects on the day of surgery, respectively, and 2.04 ± 0.91 and 2.16 ± 0.99 mm at 2 years, respectively. At 2 years, 69.3% of the patients were highly satisfied. The use of implants under standard conditions seemed to have success rates similar to their placement in controlled studies.