hamad Alhajeri

Dr. hamad Alhajeri


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
HAhamad Alhajeri
hamad Alhajeri
Abdulrahman AlmutairiAbdulrahman Almutairi
Abdulrahman Almutairi
AAABDULRAHMAN ALENEZI
ABDULRAHMAN ALENEZI
FAFaisal Alshammari
Faisal Alshammari
The present paper reports the impact of the Covid-19 pandemic on the electricity peak load and power generation in the State of Kuwait during the partial and full curfews imposed in March, April and May 2020 using historic data measured data and the predictions provided by a statistical genetic algorithm model. A quantitative assessment is made of the economic and environmental impacts caused by partial and full lockdowns. Comparison of measured peak demand for 2019 and 2020 with predicted peak demand for 2020 has: (i) enabled an accurate evaluation of residential energy consumption in the state of Kuwait at nearly 18 MWh yearly the highest energy consumption per capita in the world, (ii) shown that the imposition of the curfews to reduce the spread of COVID-19 caused a fall in the demand for electrical power of 17.6% compared with the expected demand and (iii) quantified the reduction in CO2, NOx and CO pollutant emissions produced by power plants due to less fuel being consumed. A mathematical model has been developed to predict the peak electric load in the national grid according to climatic data supplied by the Meteorological Department of Civil Aviation of Kuwait and National Control Center (NCC).

15 September 2020 in Processes
Verified
Journal Article
Open access
PDF file
HAhamad Alhajeri
hamad Alhajeri
Abdulrahman AlmutairiAbdulrahman Almutairi
Abdulrahman Almutairi
HAHamad M. Alhajeri
Hamad M. Alhajeri
AAABDULRAHMAN ALENEZI
ABDULRAHMAN ALENEZI
RARashed Alajmi
Rashed Alajmi
AKAboelyazeid Mohamed Koluib
Aboelyazeid Mohamed Koluib
The results of an experimental study to evaluate the characteristics of R-407C thermofluid during condensation in a helically coiled copper tube heat exchanger are presented. The effects of saturation temperature (Tsat), and mass and heat fluxes of refrigerant R-407C on thermal performance and pressure drop were determined. The relationship between the refrigerant wall subcooling and heat transfer coefficients was also investigated. This paper reports the effect of the temperature of the water used as cooling medium on the heat transfer rate of condensing R-407C. The study was conducted with mass flux of R-407C in the range of 100–450 kg/m2s, mass flux of the coolant water in the range of 500–5000 kg/m2s and Tsat of 31 °C, 35 °C, and 39 °C. Compared with a straight smooth tube, the use of the helical coiled (helicoidal) tube increased the condensation rate with a corresponding pressure drop that depended on the value of Tsat of the refrigerant and temperature of the coolant.

26 December 2025 in Aerospace
Verified
Journal Article
Open access
PDF file
Abdulrahman AlmutairiAbdulrahman Almutairi
Abdulrahman Almutairi
HAhamad Alhajeri
hamad Alhajeri
MZMohamed Gharib Zedan
Mohamed Gharib Zedan
HAHamad H. Almutairi
Hamad H. Almutairi
Despite substantial advances in turbofan engineering, a crucial gap persists: there remains the need for an all-inclusive comparative analysis that includes real-world operational data and evaluates the performance of modern turbofans used in aviation. Specifically, systematic investigations that examine the exergy and efficiency of turbofan engines for takeoff and cruise remain scarce. Further, the current literature needs to address rigorous performance assessments that include simultaneous consideration of the combined effects of ambient conditions (e.g., temperature, density, relative humidity), Mach number, and turbine inlet temperature on high-bypass turbofan engines used in modern, commercial aircraft. Energetic and exergetic analyses were conducted on five commercial high-bypass turbofan engines with different configurations for both takeoff and cruise flight modes. The computational thermodynamic models developed showed strong correlation with manufacturers’ specifications. Performance evaluations included variations in ambient conditions, altitude, Mach number, and turbine inlet temperature. Results demonstrate that three-spool engine architecture exhibits 70–71% reduction in exergy destruction between flight phases compared to 62.5% for two-spool designs, indicating greater operational adaptability. The combustion chamber emerged as the dominant contributor to irreversibilities, representing approximately 55–58% of overall exergy destruction during takeoff operations. Results demonstrate that increased ambient temperature and/or humidity increase both degraded exergetic efficiency and thrust-specific fuel consumption, and that Mach number and altitude influenced efficiency metrics through ram compression and density effects, while higher turbine inlet temperatures enhanced exhaust kinetic energy via increased thermal input. We show that cruise operations demonstrated superior exergetic efficiency (68–74%) compared with takeoff (47–60%) across all engine configurations. Our results confirm the fundamental trade-off in turbofan design: for long-range applications, high-bypass engines prioritize propulsive efficiency, while for power-intensive operations, moderate-bypass configurations deliver higher specific thrust.

6 January 2021 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
AAABDULRAHMAN ALENEZI
ABDULRAHMAN ALENEZI
Abdulrahman AlmutairiAbdulrahman Almutairi
Abdulrahman Almutairi
HAhamad Alhajeri
hamad Alhajeri
AGAbdelaziz Gamil
Abdelaziz Gamil
FAFaisal Alshammari
Faisal Alshammari
A detailed heat transfer numerical study of a three-dimensional impinging jet on a roughened isothermal surface is presented and is investigated from flow physics vantage point under the influence of different parameters. The effects of the Reynolds number, roughness location, and roughness dimension on the flow physics and heat transfer parameters are studied. Additionally, the relations between average heat transfer coefficient (AHTC) and flow physics including pressure, wall shear and flow vortices with thermodynamic nonequilibrium are offered. This paper studies the effect of varying both location and dimension of the roughness element which took the shape of square cross-sectional continuous ribs to deliver a favorable trade-off between total pressure loss and heat transfer rate. The roughness element was tested for three different radial locations (R/D) = 1, 1.5, and 2 and at each location its height (i.e., width) (e) was changed from 0.25 to 1 mm in incremental steps of 0.25. The study used a jet angle (α) of 90 deg, jet-to-target distance (H/D = 6), and Re ranges from 10,000 to 50,000, where H is the vertical distance between the target plate and jet exit. The results show that the AHTC can be significantly affected by changing the geometry and dimensions of the roughness element. This variation can be either an augmentation of, or decrease in, the (HTC) when compared with the baseline case. An enhancement of 12.9% in the AHTC was achieved by using optimal location and dimensions of the roughness element at specific Reynolds number. However, a diminution between 10% and 30% in (AHTC) was attained by the use of rib height e = 1 mm at Re = 50k. The variation of both rib location and height showed better contribution in increasing heat transfer for low-range Reynolds numbers.

26 February 2022 in Processes
Verified
Journal Article
Open access
PDF file
Abdulrahman AlmutairiAbdulrahman Almutairi
Abdulrahman Almutairi
AAABDULRAHMAN ALENEZI
ABDULRAHMAN ALENEZI
HAhamad Alhajeri
hamad Alhajeri
SASaad F. Almokmesh
Saad F. Almokmesh
HAHamad H. Almutairi
Hamad H. Almutairi
BABashar Alzuwayer
Bashar Alzuwayer
The results obtained from the exergoeconomic and exergy analysis of a model of a generic air conditioning (A/C) system without and with an air membrane exchanger using three commercially available refrigerants: R410A, R407C, and R134a, are reported. The model used specialized software that was validated against recently published data and showed good agreement. A/C systems are energy intensive and consume a significant portion of global electricity. Improving their efficiency by even a small amount will produce considerable savings, reduce running costs, and lower pollution emissions. The efficiency of the same A/c system without and with a membrane was investigated for different ambient temperatures, relative humidities (RHs), and pressure ratios of the compressor. It was shown that the inclusion of a membrane improved the efficiency of the system for all three refrigerants tested, particularly at higher ambient temperature. Both the coefficient of performance and exergetic efficiency reduced with the increase in the pressure ratio due to increasing fuel exergy and losses. In all system components except one, it was found that the source of the cost is inefficiencies; hence, increasing the efficiency at the expense of the non-exergy cost will improve the cost effectiveness of the entire system.

28 March 2023 in Processes
Verified
Journal Article
Open access
PDF file
HAHamad H. Almutairi
Hamad H. Almutairi
Abdulrahman AlmutairiAbdulrahman Almutairi
Abdulrahman Almutairi
SSSuleiman Mohammed Suleiman
Suleiman Mohammed Suleiman
AAABDULRAHMAN ALENEZI
ABDULRAHMAN ALENEZI
KAKhalid A. Alkhulaifi
Khalid A. Alkhulaifi
HAhamad Alhajeri
hamad Alhajeri
The decision-making process behind the selection of a gas turbine engine (GT) is crucial and must be made in accordance with economic, environmental, and technical requirements. This paper presents the relevant economic, exergoeconomic and exergoenvironmental analyses for four GT engines with different compressor configurations. The GT engine configurations are identified according to the type of compressor: axial, axial-centrifugal, two-stage centrifugal, and centrifugal-centrifugal. The performances of the four GT engines were validated against manufacturer supplied data using specialized software. The economic analysis, a detailed life cycle costing considering the cost to be paid per unit net power obtained from the GT, and subsequent shortest payback period showed that the GT with centrifugal-centrifugal compressor was most economically feasible. This was followed, in order, by the GT-axial, GT-axial-centrifugal, and finally the GT-two-stage centrifugal configuration, where the cost of ownership for a 20 year plan ranges between 8000 USD/kW to about 12,000 USD/kW at different operational scenarios during the life cycle costing. Exergoeconomic assessment provided useful information to enhance the cost-effectiveness of all four systems by evaluating each component separately. The axial-centrifugal configuration registered the lowest CO2 emissions (about 0.7 kg/kWh); all environmental indicators confirmed it is the most environmentally friendly option.