It is commonly known that buildings in hot climate contribute to a huge amount of electricity consumption mainly due to air conditioning needs. Many countries around the world are aiming to convert buildings to net zero energy buildings (NZEB). However, buildings in hot climates require varieties of active and passive measures to adapt the concepts behind NZEB. This work attempts to resolve the challenges associated with shifting school buildings to NZEB in hot arid climates. It presents an energy performance analysis that is focused on two scenarios for new and retrofitted schools. Building thermal simulation is used to assess the implications of several energy conservation measures, and different scenarios are suggested to utilize up to 80% of roof’s area for the installation of Photovoltaics (PV), and on-site wind turbines. The implemented energy conservation measures show a reduction in annual energy consumption by 35% and 21% for new and retrofitted schools respectively. Discounted payback period is used to estimate the economic feasibility of the suggested scenarios. It is found that NZEB is technically feasible at highest roof area PV installations with respective discounted paybacks of 3.55 and 5.54 years for the new and retrofitted schools. However, adding wind-turbines can delay the breakeven year of investments needed to achieve NZEB. The estimated savings in net present value (NPV) are 3273 and 4284 thousand US dollars for the retrofitted and new schools respectively, and each school’s roof can generate 40.63 GWh in 25 years and avoid 29.23 kilotons of CO2.

24 June 2023 in Processes
Verified
Journal Article
Open access
PDF file
KAKhalid A. Alkhulaifi
Khalid A. Alkhulaifi
AAAli Y. Alharbi
Ali Y. Alharbi
MAMohsen Alardhi
Mohsen Alardhi
JAJasem M Alrajhi
Jasem M Alrajhi
HAHamad H. Almutairi
Hamad H. Almutairi
Valves are important components in controlling the amount of fluid going to devices. One of these types is the butterfly valve (BFV) that adjusts the amount of flow by rotating the valve disk by means of its shafts which is usually located in the middle of the flow. Despite its common usage in various applications, the BFV is known to cause a high-pressure drop. Conversely, the pinch valve is another type of flow control device that uses a pinching mechanism to open and close the inner tube by pinching at different degrees. The absence of flow-controlling mechanisms in the flow path, such as the valve disk and its shaft, contribute to the minimal pressure drop in pinch valves. The high-pressure drop in BFVs and the minimal pressure drop in pinch valve flow make it worthwhile to investigate and compare their flow at all opening positions of the two valves. Therefore, this work numerically explores the potential of using the pinch valve as an alternative to the BFV in terms of its ability to attain a lower pressure loss, hence better flow rate. The influence of various BFV parameters such as shaft diameter, valve thickness, and valve disk edge were examined. The performance characteristics of both valves were obtained using CFD models formed on the SolidWorks program. This CFD model solves the differential equations using the finite element method. Moreover, a mathematical model to determine the area of the pinch valve at various pinching degrees was developed and compared with the results obtained from other mathematical models and CFD. It was shown that using a flat 1 mm valve disk thickness with round edges resulted in a 7.5% increase in mass flow rate compared to standard BFVs. On the other hand, using the pinch valve resulted in over a 700% mass flow rate compared to the BFV at a 25% opening position and a 49% increase in flow rate at a 75% opening position. Thus, the pinch valve has the potential to replace the BFV due to its better flow characteristics in any application.

26 December 2025 in Aerospace
Verified
Journal Article
Open access
PDF file
Abdulrahman AlmutairiAbdulrahman Almutairi
Abdulrahman Almutairi
HAhamad Alhajeri
hamad Alhajeri
MZMohamed Gharib Zedan
Mohamed Gharib Zedan
HAHamad H. Almutairi
Hamad H. Almutairi
Despite substantial advances in turbofan engineering, a crucial gap persists: there remains the need for an all-inclusive comparative analysis that includes real-world operational data and evaluates the performance of modern turbofans used in aviation. Specifically, systematic investigations that examine the exergy and efficiency of turbofan engines for takeoff and cruise remain scarce. Further, the current literature needs to address rigorous performance assessments that include simultaneous consideration of the combined effects of ambient conditions (e.g., temperature, density, relative humidity), Mach number, and turbine inlet temperature on high-bypass turbofan engines used in modern, commercial aircraft. Energetic and exergetic analyses were conducted on five commercial high-bypass turbofan engines with different configurations for both takeoff and cruise flight modes. The computational thermodynamic models developed showed strong correlation with manufacturers’ specifications. Performance evaluations included variations in ambient conditions, altitude, Mach number, and turbine inlet temperature. Results demonstrate that three-spool engine architecture exhibits 70–71% reduction in exergy destruction between flight phases compared to 62.5% for two-spool designs, indicating greater operational adaptability. The combustion chamber emerged as the dominant contributor to irreversibilities, representing approximately 55–58% of overall exergy destruction during takeoff operations. Results demonstrate that increased ambient temperature and/or humidity increase both degraded exergetic efficiency and thrust-specific fuel consumption, and that Mach number and altitude influenced efficiency metrics through ram compression and density effects, while higher turbine inlet temperatures enhanced exhaust kinetic energy via increased thermal input. We show that cruise operations demonstrated superior exergetic efficiency (68–74%) compared with takeoff (47–60%) across all engine configurations. Our results confirm the fundamental trade-off in turbofan design: for long-range applications, high-bypass engines prioritize propulsive efficiency, while for power-intensive operations, moderate-bypass configurations deliver higher specific thrust.

26 February 2022 in Processes
Verified
Journal Article
Open access
PDF file
Abdulrahman AlmutairiAbdulrahman Almutairi
Abdulrahman Almutairi
AAABDULRAHMAN ALENEZI
ABDULRAHMAN ALENEZI
HAhamad Alhajeri
hamad Alhajeri
SASaad F. Almokmesh
Saad F. Almokmesh
HAHamad H. Almutairi
Hamad H. Almutairi
BABashar Alzuwayer
Bashar Alzuwayer
The results obtained from the exergoeconomic and exergy analysis of a model of a generic air conditioning (A/C) system without and with an air membrane exchanger using three commercially available refrigerants: R410A, R407C, and R134a, are reported. The model used specialized software that was validated against recently published data and showed good agreement. A/C systems are energy intensive and consume a significant portion of global electricity. Improving their efficiency by even a small amount will produce considerable savings, reduce running costs, and lower pollution emissions. The efficiency of the same A/c system without and with a membrane was investigated for different ambient temperatures, relative humidities (RHs), and pressure ratios of the compressor. It was shown that the inclusion of a membrane improved the efficiency of the system for all three refrigerants tested, particularly at higher ambient temperature. Both the coefficient of performance and exergetic efficiency reduced with the increase in the pressure ratio due to increasing fuel exergy and losses. In all system components except one, it was found that the source of the cost is inefficiencies; hence, increasing the efficiency at the expense of the non-exergy cost will improve the cost effectiveness of the entire system.

28 March 2023 in Processes
Verified
Journal Article
Open access
PDF file
HAHamad H. Almutairi
Hamad H. Almutairi
Abdulrahman AlmutairiAbdulrahman Almutairi
Abdulrahman Almutairi
SSSuleiman Mohammed Suleiman
Suleiman Mohammed Suleiman
AAABDULRAHMAN ALENEZI
ABDULRAHMAN ALENEZI
KAKhalid A. Alkhulaifi
Khalid A. Alkhulaifi
HAhamad Alhajeri
hamad Alhajeri
The decision-making process behind the selection of a gas turbine engine (GT) is crucial and must be made in accordance with economic, environmental, and technical requirements. This paper presents the relevant economic, exergoeconomic and exergoenvironmental analyses for four GT engines with different compressor configurations. The GT engine configurations are identified according to the type of compressor: axial, axial-centrifugal, two-stage centrifugal, and centrifugal-centrifugal. The performances of the four GT engines were validated against manufacturer supplied data using specialized software. The economic analysis, a detailed life cycle costing considering the cost to be paid per unit net power obtained from the GT, and subsequent shortest payback period showed that the GT with centrifugal-centrifugal compressor was most economically feasible. This was followed, in order, by the GT-axial, GT-axial-centrifugal, and finally the GT-two-stage centrifugal configuration, where the cost of ownership for a 20 year plan ranges between 8000 USD/kW to about 12,000 USD/kW at different operational scenarios during the life cycle costing. Exergoeconomic assessment provided useful information to enhance the cost-effectiveness of all four systems by evaluating each component separately. The axial-centrifugal configuration registered the lowest CO2 emissions (about 0.7 kg/kWh); all environmental indicators confirmed it is the most environmentally friendly option.

6 July 2026 in Aerospace
Verified
Journal Article
Open access
PDF file
Abdulrahman AlmutairiAbdulrahman Almutairi
Abdulrahman Almutairi
HAHamad H. Almutairi
Hamad H. Almutairi
AAABDULRAHMAN ALENEZI
ABDULRAHMAN ALENEZI
HAhamad Alhajeri
hamad Alhajeri
Turbofan engine performance is critically sensitive to operating conditions, yet comprehensive frameworks that simultaneously assess exergo-economic, exergo-environmental, and lifecycle cost performance across realistic flight envelopes remain limited, particularly for Gulf-region climates. In this study, we present a comprehensive analysis of the exergo-economic, exergo-environmental, and lifecycle costings of five different configurations of two-spool and triple-spool turbofan engines. The analysis was carried out for a wide range of four operating conditions, namely ambient temperature, flight altitude, Mach number, and % relative humidity, with emphasis on the climate conditions likely to be found in the Gulf region. The computational models developed were validated against published data to confirm their reliability. It was found that fuel consumption was the most significant contributor to total lifecycle ownership cost, between 60 and 75% of hourly operating cost over a 20-year service period. Ambient temperature, Mach number, and Cruise altitude represented the most significant drivers of long-term economic performance, with % relative humidity having little effect. Exergo-economic analysis showed that the major cost mechanisms changed dramatically with operating conditions. Exergy destruction and component inefficiencies determined the costs at Takeoff, with capital investment being the dominant factor when cruising. Increase in both or either ambient temperature and altitude was shown to reduce cost rates but simultaneously reduced thermo-economic efficiency via higher specific exergy costs. However, increase in Mach number enhances both exergy output and cost-effectiveness, confirming that specific exergy cost is a more reliable indicator of true system performance than cost rate alone. The two-spool configurations show superior specific CO2 emissions, with Case 3 recording the lowest emissions at Takeoff and Case 2 at Cruise. For exergy-based environmental indicators, Case 3 performs best at both Takeoff and Cruise, achieving the lowest environmental destruction coefficient and index, as well as the highest environmental benign index among all five configurations. These findings provide actionable guidance for engine selection, operational optimization, and sustainable propulsion system design.